The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Elastic Moduli of Breast and Prostate Tissues under Compression
Abstract
To evaluate the dynamic range of tissue imaged by elastography, the mechanical behavior of breast and prostate tissue samples subject to compression loading has been investigated. A model for the loading was validated and used to guide the experimental design for data collection. The model allowed the use of small samples that could be considered homogeneous; this assumption was confirmed by histological analysis. The samples were tested at three strain rates to evaluate the viscoelastic nature of the material and determine the validity of modeling the tissue as an elastic material for the strain rates of interest. For loading frequencies above 1 Hz, the storage modulus accounted for over 93 percent of the complex modulus. The data show that breast fat tissue has a constant modulus over the strain range tested while the other tissues have a modulus that is dependent on the strain level. The fibrous tissue samples from the breast were found to be 1 to 2 orders of magnitude stiffer than fat tissue. Normal glandular breast tissue was found to have an elastic modulus similar to that of fat at low strain levels, but the modulus of the glandular tissue increased by an order of magnitude above fat at high strain levels. Carcinomas from the breast were stiffer than the other tissues at the higher strain level; intraductal in situ carcinomas were like fat at the low strain level and much stiffer than glandular tissue at the high strain level. Infiltrating ductal carcinomas were much stiffer than any of the other breast tissues. Normal prostate tissue has a modulus that is lower than the modulus of the prostate cancers tested. Tissue from prostate with benign prostatic hyperplasia (BPH) had modulus values significantly lower than normal tissue. There was a constant but not significant difference in the modulus of tissues taken from the anterior and posterior portions of the gland.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Elastography of breast lesions: initial clinical results.
Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F. (1997) · Radiology · doi:10.1148/radiology.202.1.8988195 · Cited by 940
Self-citationStrength of biological materials
Roberts, V. L. (1971) · Journal of Biomechanics · doi:10.1016/0021-9290(71)90027-3 · Cited by 566
Phantom materials for elastography
Hall, T. J., Bilgen, M., Insana, M. F., & Krouskop, T. A. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.656639 · Cited by 516
Self-citationImaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514
Tissue response to mechanical vibrations for “sonoelasticity imaging”
Parker, K. J., Huang, S. R., Musulin, R. A., & Lerner, R. M. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90003-u · Cited by 478
A note on the elasticity of soft biological tissues
Demiray, H. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90047-4 · Cited by 416
Elastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast In Vivo
Cespedes, I. (1993) · Ultrasonic Imaging · doi:10.1006/uimg.1993.1007 · Cited by 414
Krouskop, T. A., Dougherty, D. R., & Vinson, F. S. (1987) · PubMed · Cited by 362
Self-citationYoung's modulus measurements of soft tissues with application to elasticity imaging
Chen, E. J., Novakofski, J., Jenkins, W. K., & O'Brien, W. D. (1996) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.484478 · Cited by 312
Viscoelastic properties of human articular cartilage.
Hayes, W. C., & Mockros, L. F. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.4.562 · Cited by 306
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287
Self-citationPhonons and the elastic moduli of collagen and muscle
HARLEY, R., JAMES, D., MILLER, A., & WHITE, J. W. (1977) · Nature · doi:10.1038/267285a0 · Cited by 226
Chen, J.-F., Fowlkes, J. B., Carson, P. L., & Rubin, J. M. (1997) · International Journal of Imaging Systems and Technology · doi:10.1002/(sici)1098-1098(1997)8:1<89::aid-ima11>3.0.co;2-g · Cited by 103
Elastographic Imaging of Low-Contrast Elastic Modulus Distributions in Tissue
Kallel, F., Ophir, J., Magee, K., & Krouskop, T. A. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(97)00287-1 · Cited by 87
Self-citationShear acoustic properties of soft biological tissues in medical diagnostics
Sarvazyan, A. P. (1993) · The Journal of the Acoustical Society of America · doi:10.1121/1.406353 · Cited by 73
Techniques for elastic imaging: a review
Parker, K. J., Gao, L., Lerner, R. M., & Levinson, S. F. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.544512 · Cited by 65
MECHANICAL AND CHEMICAL PROPERTIES OF ARTERIES IN EXPERIMENTAL HYPERTENSION*
Feigl, E. O., Peterson, L. H., & JONES, A. W. (1963) · Journal of Clinical Investigation · doi:10.1172/jci104849 · Cited by 54
Stress-strain relations of tissue sheets undergoing uniform two-dimensional stretch.
Hildebrandt, J., Fukaya, H., & Martin, C. (1969) · Journal of Applied Physiology · doi:10.1152/jappl.1969.27.5.758 · Cited by 41
Stress-strain relationships during uniform and nona uniform expansion of isolated lungs
D’Angelo, E. (1975) · Respiration Physiology · doi:10.1016/0034-5687(75)90074-2 · Cited by 31
Elastic properties of fixed and fresh muscle
Galey, F. R. (1969) · Journal of Ultrastructure Research · doi:10.1016/s0022-5320(69)90049-5 · Cited by 11
Bakke, T. (1973) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.3109/00016347309158327 · Cited by 11
The determination of the constitutive relationships for a human aorta
Krokosky, E. M., & Krouskop, T. A. (1970) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820040405 · Cited by 7
Self-citationSynthetic aortas for systemic simulators
Krokosky, E. M., & Krouskop, T. A. (1968) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820020306 · Cited by 5
Self-citation
Cited by
Matrix Crosslinking Forces Tumor Progression by Enhancing Integrin Signaling
Levental, K. R., Yu, H., Kass, L., Lakins, J. N., Egeblad, M., Erler, J. T., Fong, S. F. T., Csiszar, K., Giaccia, A., Weninger, W., et al. (2009) · Cell · doi:10.1016/j.cell.2009.10.027 · Cited by 4,101
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Metadata
- Authors
- Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1998-10
- Volume
- 20
- Issue
- 4
- Pages
- 260-274
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2071027495
- Cited by
- 1,703
- References
- 24
- FWCI
- 12.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.