CoChat

Optimization of Graft Fixation at the Time of Anterior Cruciate Ligament Reconstruction: Part II: Effect of Knee Flexion Angle

Mae, Tatsuo, Shino, Konsei, Nakata, Ken, Toritsuka, Yukiyoshi, Otsubo, Hidenori, Fujie, Hiromichi · 2008 · The American Journal of Sports Medicine

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Background: There is no consensus about flexion angle of the knee at the time of graft fixation in anterior cruciate ligament reconstruction. Purpose: To evaluate the effect of flexion angle at the final graft fixation on the positional relationship as well as the load between femur and tibia. Study Design: Controlled laboratory study. Methods: Six intact cadaveric knees were passively flexed and extended under 6 degrees of freedom with the robotic system developed in our laboratory, while their 3-dimensional paths were recorded. Anterior cruciate ligament reconstruction was performed with a single-socket technique using autogenous quadrupled hamstring tendons, while the graft was fixed at 0° (group A) 20° (group B) or 90° (group C) with a constant initial tension of 44 N. The knees then repeated the same movement as before while the relative position between femur and tibia was recorded. The load in the femorotibial joint was also calculated based on the principle of superposition. Results: Posterior displacement of the tibia compared with the normal knee was the smallest in group B at all flexion angles, while the load between tibia and femur in group B was also the smallest and the closest to the normal knee. Conclusion: As the positional relationship as well as the load between femur and tibia in group B was the closest to that in the normal knee, 20° of flexion is the most desirable of the positions tested for graft tensioning and fixation at the time of anterior cruciate ligament reconstruction. Clinical Relevance: The tibia-femur position is well retained when the graft was fixed at 20° of flexion in anterior cruciate ligament reconstruction.

Overview

Integrity signals

Registry

Crossref · 10.1177/0363546508317412

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 2

  1. Rosenberg TD, 1994, Techniques for ACL Reconstruction With Multi-Trac Drill Guide
  2. Sekito T, 1997, Proceedings, 1997 Bioengineering Conference (ASME), 35, 393

Cited by

See all 77

Metadata

Authors
Mae, T., Shino, K., Nakata, K., Toritsuka, Y., Otsubo, H., & Fujie, H.
Affiliations
  • Kansai Rosai Hospital (JP)
  • Osaka Prefecture University (JP)
  • Osaka University Hospital (JP)
  • Kogakuin University (JP)
Corresponding author
Mae, Tatsuo
Venue
The American Journal of Sports Medicine
Published
2008-05-09
Volume
36
Issue
6
Pages
1094-1100
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2010522039
Cited by
77
References
25
Citations by year
2025: 1 · 2024: 1 · 2023: 2 · 2022: 9 · 2021: 8 · 2020: 2 · 2019: 2 · 2018: 8 · 2017: 4 · 2016: 4 · 2015: 4 · 2014: 7 · 2013: 5 · 2012: 4
FWCI
5.62
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • The American Journal of Sports Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
Keywords
anterior cruciate ligament reconstruction, graft fixation, knee flexion angle, graft tensioning, quadrupled hamstring tendon graft, cadaveric knee biomechanics
MeSH terms
Biomechanical Phenomena, Cadaver, Femur, Humans, Knee Joint, Movement, Tibia, Anterior Cruciate Ligament, Plastic Surgery Procedures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.