Optimization of Graft Fixation at the Time of Anterior Cruciate Ligament Reconstruction: Part II: Effect of Knee Flexion Angle
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background: There is no consensus about flexion angle of the knee at the time of graft fixation in anterior cruciate ligament reconstruction. Purpose: To evaluate the effect of flexion angle at the final graft fixation on the positional relationship as well as the load between femur and tibia. Study Design: Controlled laboratory study. Methods: Six intact cadaveric knees were passively flexed and extended under 6 degrees of freedom with the robotic system developed in our laboratory, while their 3-dimensional paths were recorded. Anterior cruciate ligament reconstruction was performed with a single-socket technique using autogenous quadrupled hamstring tendons, while the graft was fixed at 0° (group A) 20° (group B) or 90° (group C) with a constant initial tension of 44 N. The knees then repeated the same movement as before while the relative position between femur and tibia was recorded. The load in the femorotibial joint was also calculated based on the principle of superposition. Results: Posterior displacement of the tibia compared with the normal knee was the smallest in group B at all flexion angles, while the load between tibia and femur in group B was also the smallest and the closest to the normal knee. Conclusion: As the positional relationship as well as the load between femur and tibia in group B was the closest to that in the normal knee, 20° of flexion is the most desirable of the positions tested for graft tensioning and fixation at the time of anterior cruciate ligament reconstruction. Clinical Relevance: The tibia-femur position is well retained when the graft was fixed at 20° of flexion in anterior cruciate ligament reconstruction.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“To replicate the ACL reconstruction completely, a model at 20° of knee flexion and an initial graft tension of 80 N were used [18, 19].”
Citations
Cites
Patellar Tendon or Semitendinosus Tendon Autografts for Anterior Cruciate Ligament Reconstruction
Liden, M., Ejerhed, L., Sernert, N., Laxdal, G., & Kartus, J. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506298275 · Cited by 439 · cited 1×
“1094 Anterior cruciate ligament (ACL) reconstruction has been widely and successfully performed thanks to recent innovations of surgical instruments and improvement of surgical techniques.(8,9,17) However, there is no consensus about the position of the knee during tensioning and fixing ACL grafts at the time of recon…”
BackgroundAnterior cruciate ligament graft positioning, tensioning and twisting
Amis, A. A., & Jakob, R. P. (1998) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050215 · Cited by 387
Adachi, N., Ochi, M., Uchio, Y., Iwasa, J., Kuriwaka, M., & Ito, Y. (2004) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.86b4.14856 · Cited by 364 · cited 1×
“There is literature that includes graft fixation technique, whereas other literature reports different knee positions at the time of graft fixation.(1,5,19,26) According to Amis and Jakob,(2) the surgeons who participated in the Optimization of Graft Fixation at the Time of Anterior Cruciate Ligament Reconstruction”
BackgroundEjerhed, L., Kartus, J., Sernert, N., Köhler, K., & Karlsson, J. (2003) · The American Journal of Sports Medicine · doi:10.1177/03635465030310011401 · Cited by 334
Anterior Cruciate Ligament Reconstruction with Multistranded Autogenous Semitendinosus Tendon
Maeda, A., Shino, K., Horibe, S., Nakata, K., & Buccafusca, G. (1996) · The American Journal of Sports Medicine · doi:10.1177/036354659602400416 · Cited by 274 · cited 1×
“1094 Anterior cruciate ligament (ACL) reconstruction has been widely and successfully performed thanks to recent innovations of surgical instruments and improvement of surgical techniques.(8,9,17) However, there is no consensus about the position of the knee during tensioning and fixing ACL grafts at the time of recon…”
BackgroundSelf-citationSingle– versus two–femoral socket anterior cruciate ligament reconstruction technique
Mae, T., Shino, K., Miyama, T., Shinjo, H., Ochi, T., Yoshikawa, H., & Fujie, H. (2001) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2001.25250 · Cited by 240
Self-citationFujie, H., Livesay, G. A., Woo, S. L.-Y., Kashiwaguchi, S., & Blomstrom, G. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2792266 · Cited by 233 · cited 2×
“As this system has a high reproducibility, the load between femur and tibia can be calculated with the principle of superposition.(11) The ACL-reconstructed knee in which the graft was fixed at the optimal knee position could be assumed close to the normal knee in relative tibia-femur position or in load in the knee s…”
MethodSelf-citationYasuda, K., Tsujino, J., Tanabe, Y., & Kaneda, K. (1997) · The American Journal of Sports Medicine · doi:10.1177/036354659702500120 · Cited by 214 · cited 1×
“There is literature that includes graft fixation technique, whereas other literature reports different knee positions at the time of graft fixation.(1,5,19,26) According to Amis and Jakob,(2) the surgeons who participated in the Optimization of Graft Fixation at the Time of Anterior Cruciate Ligament Reconstruction”
BackgroundBylski‐Austrow, D. I., Grood, E. S., Hefzy, M. S., Holden, J. P., & Butler, D. L. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080408 · Cited by 198
Determination of graft tension before fixation in anterior cruciate ligament reconstruction
Burks, R. T., & Leland, R. (1988) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(88)80041-0 · Cited by 145 · cited 1×
“However, according to previous reports, the optimal initial tension depends on the operative procedure and the type of graft.(6,15) In this study, the A-P laxity in 3 experimental groups with the initial tension of 44 N applied was not smaller than that in the normal knee, suggesting that the initial tension of 44 N i…”
Method
Research works printed but not linked: 2
- Rosenberg TD, 1994, Techniques for ACL Reconstruction With Multi-Trac Drill Guide
- Sekito T, 1997, Proceedings, 1997 Bioengineering Conference (ASME), 35, 393
Cited by
Bates, N. A., Myer, G. D., Shearn, J. T., & Hewett, T. E. (2014) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.12.006 · Cited by 82
Suzuki, T., Shino, K., Otsubo, H., Suzuki, D., Mae, T., Fujimiya, M., Yamashita, T., & Fujie, H. (2014) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2014.05.027 · Cited by 67
Self-citationA Systematic Review of Risk Factors for Anterior Cruciate Ligament Reconstruction Failure
Shen, X., Qin, Y., Zuo, J., Liu, T., & Xiao, J. (2021) · International Journal of Sports Medicine · doi:10.1055/a-1393-6282 · Cited by 63
Mae, T., Shino, K., Matsumoto, N., Natsu-ume, T., Yoneda, K., Yoshikawa, H., & Yoneda, M. (2010) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2010.02.017 · Cited by 55
Self-citationConner, C. S., Perez, B. A., Morris, R. P., Buckner, J. W., Buford, W. L., & Ivey, F. M. (2010) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2009.10.015 · Cited by 53
Murray, P. J., Alexander, J. W., Gold, J. E., Icenogle, K. D., Noble, P. C., & Lowe, W. R. (2010) · Arthroscopy · doi:10.1016/j.arthro.2009.07.014 · Cited by 48
Petrigliano, F. A., Musahl, V., Suero, E. M., Citak, M., & Pearle, A. D. (2011) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-011-1537-6 · Cited by 42
“Axial tension of 44 N on the draw sutures was applied to each graft, and the sutures were secured over a screw post [19, 26].”
MethodEtiologic Factors That Lead to Failure After Primary Anterior Cruciate Ligament Surgery
Wylie, J. D., Marchand, L. S., & Burks, R. T. (2016) · Clinics in Sports Medicine · doi:10.1016/j.csm.2016.08.007 · Cited by 42
“The concern with undertightening is that this may lead to persistent instability, whereas over-tightening may have deleterious effects on cartilage by increasing joint contact forces.(105,106) Furthermore, with manual surgeon tensioning concerns about inconsistent tension application between patients persists and, hen…”
BackgroundOutcome of double‐bundle ACL reconstruction using hamstring tendons
Toritsuka, Y., Amano, H., Kuwano, M., Iwai, T., Mae, T., Ohzono, K., & Shino, K. (2009) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-008-0707-7 · Cited by 39
Self-citationFu, S., Cheng, W. H., Cheuk, Y., Mok, T. Y., Rolf, C. G., Yung, P. S., & Chan, K.-M. (2012) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-012-1974-x · Cited by 37
“However, overtension may lead to excessive tibial femoral compressive force, which might increase the risk of cartilage injury for BPTB graft [5] and hamstring tendon graft [10].”
BackgroundTajima, T., Yamaguchi, N., Nagasawa, M., Morita, Y., Nakamura, Y., & Chosa, E. (2019) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-019-2653-6 · Cited by 36
Tibial-graft fixation methods on anterior cruciate ligament reconstructions: a literature review
Pereira, V. L., Medeiros, J. V., Nunes, G., OLIVEIRA, G. T. D., & Nicolini, A. P. (2021) · Knee Surgery and Related Research · doi:10.1186/s43019-021-00089-0 · Cited by 35
Shoji, H., Teramoto, A., Sakakibara, Y., Kamiya, T., Watanabe, K., Fujie, H., & Yamashita, T. (2019) · The American Journal of Sports Medicine · doi:10.1177/0363546518820527 · Cited by 33
Self-citationAnibal Debandi, L., Maeyama, A., Hoshino, Y. Y., Asai, S., Goto, B., Smolinski, P. J., & Fu, F. H. (2016) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2016.03.018 · Cited by 32
“Mae et al.(2) in a cadaver study using a robotic/universal force-moment sensor testing system evaluated the effect of the knee flexion angle (0 , 20 , and 90 ) for graft fixation on the positional relation and load between the femur and tibia.”
BackgroundWang, J. H., Kato, Y., Ingham, S. J. M., Maeyama, A., Linde‐Rosen, M., Smolinski, P., & Fu, F. H. (2012) · Arthroscopy · doi:10.1016/j.arthro.2012.03.004 · Cited by 30
Forsythe, B., Lansdown, D. A., Zuke, W. A., Verma, N. N., Cole, B. J., Bach, B. R., & Inoue, N. (2018) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2018.03.033 · Cited by 35
Lertwanich, P., Kato, Y., Martins, C. A. Q., Maeyama, A., Ingham, S. J. M., Kramer, S., Linde-Rosen, M., Smolinski, P. J., & Fu, F. H. (2011) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2010.12.001 · Cited by 30
Koga, H., Muneta, T., Yagishita, K., Watanabe, T., Mochizuki, T., Horie, M., Nakamura, T., Otabe, K., & Sekiya, I. (2015) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2015.03.012 · Cited by 29
Beidokhti, H. N., Janssen, D. W., van Tienen, T. G., van de Groes, S., van den Boogaard, A. H., & Verdonschot, N. J. J. (2020) · The Knee · doi:10.1016/j.knee.2020.01.010 · Cited by 30
Amano, H., Tanaka, Y., Kita, K., Uchida, R., Tachibana, Y., Yonetani, Y., Mae, T., Shiozaki, Y., & Horibe, S. (2018) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-018-5098-9 · Cited by 28
Self-citationAmano, H., Toritsuka, Y., Uchida, R., Mae, T., Ohzono, K., & Shino, K. (2014) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-014-2950-4 · Cited by 28
Self-citationPretensioning of Soft Tissue Grafts in Anterior Cruciate Ligament Reconstruction
Pilia, M., Murray, M., Guda, T., Heckman, M. M., & Appleford, M. R. (2015) · Orthopedics · doi:10.3928/01477447-20150701-55 · Cited by 27
Preoperative Planning for ACL Revision Surgery
Osti, L., Buda, M., Osti, R., Massari, L., & Maffulli, N. (2016) · Sports Medicine and Arthroscopy Review · doi:10.1097/jsa.0000000000000140 · Cited by 24
Use of Robotic Manipulators to Study Diarthrodial Joint Function
Debski, R. E., Yamakawa, S., Musahl, V., & Fujie, H. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4035644 · Cited by 23
Self-citationEvaluation of anterior cruciate ligament surgical reconstruction through finite element analysis
Risvas, K., Stanev, D., Benos, L. T., Filip, K., Tsaopoulos, D. E., & Μουστάκας, Κ. (2022) · Scientific Reports · doi:10.1038/s41598-022-11601-1 · Cited by 22
Tibiofemoral relationship following anatomic triple‐bundle anterior cruciate ligament reconstruction
Matsuo, T., Mae, T., Shino, K., Kita, K., Tachibana, Y., Sugamoto, K., Yoshikawa, H., & Nakata, K. (2013) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-013-2646-1 · Cited by 27
“In the previous biomechanical studies, the excessive graft tension caused posterior displacement and external rotation of the tibia compared with normal knees [27].”
BackgroundSelf-citationRuptur des vorderen Kreuzbands: Diagnostik und Therapie
Teske, W., Anastisiadis, A., Lichtinger, T. K., Pellengahr, C. V. S., von Engelhardt, L. V., & Theodoridis, T. (2010) · Der Orthopäde · doi:10.1007/s00132-010-1670-9 · Cited by 26
Morrison, L., Haldane, C. E., de SA, D. L., Findakli, F., Simunovic, N., & Ayeni, O. R. (2018) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-018-4951-1 · Cited by 19
Scanlan, S. F., Donahue, J. P., & Andriacchi, T. P. (2013) · The Knee · doi:10.1016/j.knee.2013.06.003 · Cited by 18
Synovec, J. D., Shaw, K. A., Antosh, I. J., Grassbaugh, J. A., Tucker, C. J., Parada, S. A., & Arrington, E. D. (2018) · Military Medicine · doi:10.1093/milmed/usy142 · Cited by 18
Sasaki, Y., Chang, S., Fujii, M., Araki, D., Zhu, J., Marshall, B., Linde-Rosen, M., Smolinski, P. J., & Fu, F. H. (2015) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-015-3552-5 · Cited by 17
Kusano, M., Kazui, A., Uchida, R., Mae, T., Tsuda, T., & Toritsuka, Y. (2018) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2018.06.034 · Cited by 17
Self-citationChahal, J., Whelan, D. B., Hoit, G., Theodoropoulos, J. S., Ajrawat, P., Betsch, M., Docter, S., & Dwyer, T. (2021) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2021.12.018 · Cited by 17
Conner, C. S., Morris, R. P., Vallurupalli, S., Buford, W. L., & Ivey, F. M. (2008) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2008.07.006 · Cited by 16
Tajima, T., Chosa, E., Kawahara, K., & Yamaguchi, N. (2014) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2014.10.015 · Cited by 15
Xiao, Y., Ling, M., Liang, Z., Ding, J., Zhan, S., Hu, H., & Chen, B. (2021) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-021-02307-2 · Cited by 14
Rhee, P. C., Levy, B. A., Stuart, M. J., Thoreson, A. R., An, K., & Dahm, D. L. (2011) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-010-1366-z · Cited by 14
Sakakibara, Y., Teramoto, A., Takagi, T., Yamakawa, S., Shoji, H., Okada, Y., Kobayashi, T., Kamiya, T., Fujimiya, M., Fujie, H., et al. (2020) · The American Journal of Sports Medicine · doi:10.1177/0363546520902725 · Cited by 15
“During pretension exertion or fixation of the graft, the robotic arm holding the calcaneus was able to freely move under UFS control, allowing 4 DOF (plantarflexion-dorsiflexion [PF-DF] and IR-ER angles were immobilized).(28,29)”
MethodSelf-citationFlury, A., Wild, L., Waltenspül, M., Zindel, C., Vlachopoulos, L., Imhoff, F. B., & Fucentese, S. F. (2022) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-022-04408-2 · Cited by 12
Tibial displacement with stifle joint flexion and cranial cruciate ligament transection in the dog
Hara, Y., FUKANO, S., Fujie, H., Ochi, H., Fujita, Y., Yasuji, H., Nezu, Y., Yogo, T., Tagawa, M., & Kanno, N. (2014) · Veterinary and Comparative Orthopaedics and Traumatology · doi:10.3415/vcot-13-06-0080 · Cited by 12
“Preliminary studies indicated that the manipulator had a positional accuracy of less than 120 nanometres under an application of 500 N to the clamp and had a clamp-to-clamp stiffness of greater than 312 N/mm (16).”
BackgroundSelf-citationNishizawa, Y., Hoshino, Y. Y., Nagamune, K., Araki, D., Nagai, K., Kurosaka, M., & Kuroda, R. (2017) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2016.11.021 · Cited by 11
Sakakibara, Y., Teramoto, A., Takagi, T., Yamakawa, S., Shoji, H., Okada, Y., Kobayashi, T., Kamiya, T., Fujimiya, M., Fujie, H., et al. (2022) · Foot & Ankle International · doi:10.1177/10711007211069327 · Cited by 11
Self-citationSakakibara, Y., Teramoto, A., Takagi, T., Yamakawa, S., Okada, Y., Shoji, H., Kobayashi, T., Fujimiya, M., Fujie, H., Watanabe, K., et al. (2018) · The American Journal of Sports Medicine · doi:10.1177/0363546518790254 · Cited by 9
Self-citationLuites, J. W. H., Wymenga, A. B., Blankevoort, L., Kooloos, J. G. M., & Verdonschot, N. J. J. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.004 · Cited by 9
Bastian, J. D., Tomagra, S., Schuster, A. J., Werlen, S. F., Jakob, R. P., & Zumstein, M. A. (2013) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-013-2465-4 · Cited by 9
“osteoarthritis [10, 22] may account for this observation.”
Huang, W., Ong, M. T., Man, G. C. W., Yang, L., Lau, L. C., & Yung, P. S. (2021) · The American Journal of Sports Medicine · doi:10.1177/0363546521995546 · Cited by 8
Mulcahey, M. K., Monchik, K. O., Yongpravat, C., Badger, G. J., Fadale, P. D., Hulstyn, M. J., & Fleming, B. C. (2011) · The Knee · doi:10.1016/j.knee.2011.05.004 · Cited by 7
“Other studies suggest tensioning both bundles between 15° and 20°, thereby avoiding excessive stress in either bundle, which may produce stress shielding in the other [3,14,21,22,49–52].”
BackgroundAdouni, M., Faisal, T. R., & Dhaher, Y. Y. (2021) · The Journal of Knee Surgery · doi:10.1055/s-0041-1733879 · Cited by 8
Compagnoni, R., Klasan, A., Grassi, A., Puglia, F., Zaffagnini, S., Randelli, P. S., & Ménétrey, J. (2025) · Journal of Experimental Orthopaedics · doi:10.1002/jeo2.70312 · Cited by 6
Wagih, A. M. (2013) · Arthroscopy Techniques · doi:10.1016/j.eats.2013.08.008 · Cited by 6
Kernkamp, W. A., Varady, N. H., Li, J., Asnis, P. D., van Arkel, E. R. A., Nelissen, R. G. H. H., de Velde, S. K. V., & Li, G. (2018) · The Knee · doi:10.1016/j.knee.2018.07.013 · Cited by 6
Iuchi, R., Mae, T., Tachibana, Y., Shino, K., Nakagawa, S., Yoshikawa, H., & Nakata, K. (2018) · Orthopaedic Journal of Sports Medicine · doi:10.1177/2325967118791183 · Cited by 6
Self-citationTakagi, K., Taketomi, S., Inui, H., Yamagami, R., Kawaguchi, K., Sameshima, S., Kage, T., Tahara, K., & Tanaka, S. (2022) · The Knee · doi:10.1016/j.knee.2022.06.007 · Cited by 5
Kent, R., Amirtharaj, M. J., Berube, E. E., Imhauser, C. W., Thein, R., Voleti, P. B., Wickiewicz, T. L., Pearle, A. D., & Nawabi, D. H. (2021) · The Knee · doi:10.1016/j.knee.2021.08.003 · Cited by 5
Asai, K., Nakase, J., Yoshimizu, R., Kimura, M., Kanayama, T., Yanatori, Y., & Tsuchiya, H. (2022) · The Knee · doi:10.1016/j.knee.2022.11.015 · Cited by 5
Constant, C., Braïlovski, V., Wagnac, É., Petit, Y., Desrochers, A., & Nichols, S. (2021) · Veterinary Surgery · doi:10.1111/vsu.13715 · Cited by 5
Fayed, A. M., Kanto, R., Price, T. M., DiNenna, M. A., Linde, M. A., Smolinski, P. J., & van Eck, C. F. (2022) · Orthopaedic Journal of Sports Medicine · doi:10.1177/23259671221118587 · Cited by 4
“Both grafts were fixed first on the femoral side with the extracortical button, then each tensioned at 40 N using a tensiometer (Meira) at 30 of flexion for the ACL graft and 90 of flexion for the PCL graft, and fixed on the tibia with a screw and spike washer.(2,35,52,56,59,64,67) All specimens were randomized to hav…”
MethodComparison of the Retro Screw and Standard Interference Screw for ACL Reconstruction
Wang, R., Arciero, R. A., Obopilwe, E., & Mazzocca, A. D. (2012) · The Journal of Knee Surgery · doi:10.1055/s-0031-1299663 · Cited by 3
Tajima, T., Yamaguchi, N., Morita, Y., Yokoe, T., Nagasawa, M., Ota, T., Kawagoe, S., Nakamura, Y., & Chosa, E. (2022) · The Journal of Knee Surgery · doi:10.1055/s-0042-1749603 · Cited by 3
Khalik, H. A., Lameire, D. L., Kay, J., Tapasvi, S. R., Samuelsson, K., & de SA, D. L. (2022) · Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine · doi:10.1016/j.jisako.2022.01.003 · Cited by 2
Reconstrução anatômica do ligamento cruzado anterior: uma abordagem lógica
Gali, J. C. (2014) · Revista Brasileira de Ortopedia · doi:10.1016/j.rbo.2014.07.003 · Cited by 2
Implantatfreier Ersatz des vorderen Kreuzbandes in Double-bundle-Technik
Boszotta, H. (2010) · Der Unfallchirurg · doi:10.1007/s00113-010-1830-8 · Cited by 2
Mae, T., & Fleming, B. C. (2017) · Springer eBooks · doi:10.1007/978-3-662-52742-9_27 · Cited by 4
Self-citationA tale of 10 European centres – 2010 APOSSM travelling fellowship review in ACL surgery
Lee, Y. H. D., Kuroda, R., Zhao, J., & Chan, K. M. (2012) · Sports Medicine Arthroscopy Rehabilitation Therapy & Technology · doi:10.1186/1758-2555-4-27 · Cited by 1
Yokoe, T., Tajima, T., Yamaguchi, N., Morita, Y., & Chosa, E. (2022) · The Journal of Knee Surgery · doi:10.1055/a-1934-0776 · Cited by 1
Anterior Cruciate Ligament Injury
Boden, S. A., Drain, N. P., Musahl, V., & Fu, F. H. (2023) · Springer eBooks · doi:10.1007/978-3-030-65430-6_31-1 · Cited by 1
Anatomical reconstruction of the anterior cruciate ligament: a logical approach
Gali, J. C. (2015) · Revista Brasileira de Ortopedia (English Edition) · doi:10.1016/j.rboe.2015.06.014 · Cited by 1
Maharjan, R., Costi, J. J., Stanley, R. M., Martin, D. K., Hearn, T. C., & Field, J. R. (2011) · Journal of Orthopaedic Surgery and Research · doi:10.1186/1749-799x-6-33 · Cited by 1
Graft Tensioning in Anterior Cruciate Ligament Reconstruction
Yasuda, K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-38962-4.00059-x · Cited by 1
Technical Causes of ACL Graft Failure
Blackman, A. J., Bogunovic, L., Cherney, S. M., & Wright, R. W. (2013) · Springer eBooks · doi:10.1007/978-1-4614-0766-9_5
Tensioning of Grafts: Any Evidence?
Scheffler, S. U. (2014) · Springer eBooks · doi:10.1007/978-3-642-45349-6_23
Anterior Cruciate Ligament Reconstruction Using Autogenous Hamstring Tendons
Mologne, T. S. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-3277-9.50038-3
Biomechanics of the knee joint after anatomical anterior cruciate ligament reconstruction
Song, S. Y., Chung, H.-M., & Seo, Y. (2016) · Arthroscopy and Orthopedic Sports Medicine · doi:10.14517/aosm16009
Shino, K. (2023) · Springer eBooks · doi:10.1007/978-981-99-6536-6_7
Self-citationIshii, D., Sato, S., & Fujie, H. (2024) · Annals of Biomedical Engineering · doi:10.1007/s10439-024-03654-2 · Cited by 1
Self-citation
Metadata
- Authors
- Mae, T., Shino, K., Nakata, K., Toritsuka, Y., Otsubo, H., & Fujie, H.
- Affiliations
- Kansai Rosai Hospital (JP)
- Osaka Prefecture University (JP)
- Osaka University Hospital (JP)
- Kogakuin University (JP)
- Corresponding author
- Mae, Tatsuo
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2008-05-09
- Volume
- 36
- Issue
- 6
- Pages
- 1094-1100
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2010522039
- Cited by
- 77
- References
- 25
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 9 · 2021: 8 · 2020: 2 · 2019: 2 · 2018: 8 · 2017: 4 · 2016: 4 · 2015: 4 · 2014: 7 · 2013: 5 · 2012: 4
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The American Journal of Sports Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
- Keywords
- anterior cruciate ligament reconstruction, graft fixation, knee flexion angle, graft tensioning, quadrupled hamstring tendon graft, cadaveric knee biomechanics
- MeSH terms
- Biomechanical Phenomena, Cadaver, Femur, Humans, Knee Joint, Movement, Tibia, Anterior Cruciate Ligament, Plastic Surgery Procedures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.