Platelet-Rich Fibrin Matrix in the Management of Arthroscopic Repair of the Rotator Cuff: A Prospective, Randomized, Double-Blinded Study
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Background: Arthroscopic rotator cuff repair has a high rate of patient satisfaction. However, multiple studies have shown significant rates of anatomic failure. Biological augmentation would seem to be a reasonable technique to improve clinical outcomes and healing rates. Purpose: To represent a prospective, double-blinded, randomized study to assess the use of platelet-rich fibrin matrix (PRFM) in rotator cuff surgery. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: Prestudy power analysis demonstrated that a sample size of 30 patients in each group (PRFM vs control) would allow recognition of a 20% difference in perioperative pain scores. Sixty consecutive patients were randomized to either receive a commercially available PRFM product or not. Preoperative and postoperative range of motion (ROM), University of California–Los Angeles (UCLA), and Simple Shoulder Test (SST) scores were recorded. Surgery was performed using an arthroscopic single-row technique. Visual analog scale (VAS) pain scores were obtained upon arrival to the recovery room and 1 hour postoperatively, and narcotic consumption was recorded and converted to standard narcotic equivalents. The SST and ROM measurements were taken at 3, 6, 9, and 12 weeks postoperatively, and final (1 year) American Shoulder and Elbow Surgeons (ASES) shoulder and UCLA shoulder scores were assessed. Results: There were no complications. Randomization created comparable groups except that the PRFM group was younger than the control group (mean ± SD, 59.67 ± 8.16 y vs 64.50 ± 8.59 y, respectively; P < .05). Mean surgery time was longer for the PRFM group than for the control group (83.28 ± 17.13 min vs 73.28 ± 17.18 min, respectively; P < .02). There was no significant difference in VAS scores or narcotic use between groups and no statistically significant differences in recovery of motion, SST, or ASES scores. Mean ASES scores were 82.48 ± 8.77 (PRFM group) and 82.52 ± 12.45 (controls) (F 1,56 = 0.00, P > .98). Mean UCLA shoulder scores were 27.94 ± 4.98 for the PRFM group versus 29.59 ± 1.68 for the controls ( P < .046). Structural results correlated with age and size of the tear and did not differ between the groups. Conclusion: Platelet-rich fibrin matrix was not shown to significantly improve perioperative morbidity, clinical outcomes, or structural integrity. While longer term follow-up or different platelet-rich plasma formulations may show differences, early follow-up does not show significant improvement in perioperative morbidity, structural integrity, or clinical outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Galatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K. (2004) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-200402000-00002 · Cited by 2,145 · cited 1×
“Despite the clinical success, anatomic failure has been documented in as many as 80% of repairs on followup imaging studies.(7,18) Double-row repair has shown improvement in some studies(43) but has not substantially improved clinical results.”
BackgroundPlatelet-Rich Plasma: From Basic Science to Clinical Applications
Foster, T. E., Puskas, B. L., Mandelbaum, B. R., Gerhardt, M. B., & Rodeo, S. A. (2009) · The American Journal of Sports Medicine · doi:10.1177/0363546509349921 · Cited by 1,323
Treatment of Chronic Elbow Tendinosis with Buffered Platelet-Rich Plasma
Mishra, A., & Pavelko, T. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506288850 · Cited by 913
Platelet-Rich Plasma and Platelet Gel: A Review
Everts, P. A. M., Knape, J. T. A., Weibrich, G., Schönberger, J. P. A. M., Hoffmann, J., Overdevest, E. P., Box, H. A. M., & van Zundert, A. (2006) · The Journal of ExtraCorporeal Technology · doi:10.1051/ject/200638174 · Cited by 580 · cited 1×
“In response to the interest generated, numerous review articles on PRP are now available.(8,16,17,22,31) All are clear that while these products may show promise, none is recommended for widespread clinical use.”
BackgroundCuff integrity after arthroscopic versus open rotator cuff repair: A prospective study
Bishop, J., Klepps, S., Lo, I. K., Bird, J., Gladstone, J. N., & Flatow, E. L. (2006) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2005.09.017 · Cited by 578 · cited 2×
“Despite the clinical success, anatomic failure has been documented in as many as 80% of repairs on followup imaging studies.(7,18) Double-row repair has shown improvement in some studies(43) but has not substantially improved clinical results.”
BackgroundResultBhandari, M., Busse, J. W., Jackowski, D., Montori, V. M., Schünemann, H. J., Sprague, S., Mears, D., Schemitsch, E. H., Heels-Ansdell, D., & Devereaux, P. J. (2004) · Europe PMC (PubMed Central) · Cited by 551
Castillo, T. N., Pouliot, M. A., Kim, H. J., & Dragoo, J. L. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510387517 · Cited by 498
Castricini, R., Longo, U. G., De Benedetto, M., Panfoli, N., Pirani, P., Zini, R., Maffulli, N., & Denaro, V. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510390780 · Cited by 487
Treatment of Tendon and Muscle Using Platelet-Rich Plasma
Mishra, A., Woodall, J., & Vieira, A. (2009) · Clinics in Sports Medicine · doi:10.1016/j.csm.2008.08.007 · Cited by 446 · cited 1×
“In response to the interest generated, numerous review articles on PRP are now available.(8,16,17,22,31) All are clear that while these products may show promise, none is recommended for widespread clinical use.”
BackgroundPlatelet rich plasma in arthroscopic rotator cuff repair: a prospective RCT study, 2-year follow-up
Randelli, P., Arrigoni, P., Ragone, V., Aliprandi, A., & Cabitza, P. (2011) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2011.02.008 · Cited by 444
Platelet-rich Plasma: Current Concepts and Application in Sports Medicine
Hall, M. P., Band, P. A., Meislin, R. J., Jazrawi, L. M., & Cardone, D. A. (2009) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200910000-00002 · Cited by 405 · cited 2×
“They vary in terms of preparation significantly.(3,22) Calcium is used to form the clot for the PRFM in this study and would seem to be more desirable in terms of delayed release of growth factors.”
BackgroundMethodRodeo, S. A., Delos, D., Williams, R. J., Adler, R. S., Pearle, A., & Warren, R. F. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546512442924 · Cited by 344 · cited 3×
“Larger sample sizes and longer follow-up would always be ideal, although these numbers are similar to those reported by Rodeo et al.(39) Because this particular product did not prove to be effective, it is not to say that other products or techniques might prove useful.”
BackgroundResultBMP‐12 gene transfer augmentation of lacerated tendon repair
Lou, J., Tu, Y., Burns, M., Silva, M. J., & Manske, P. (2001) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00042-0 · Cited by 239
Rotator Cuff Repair Healing Influenced by Platelet-Rich Plasma Construct Augmentation
Barber, F. A., Hrnack, S. A., Snyder, S. J., & Hapa, O. (2011) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.06.010 · Cited by 233
Does Platelet-Rich Plasma Accelerate Recovery After Rotator Cuff Repair? A Prospective Cohort Study
Jo, C. H., Kim, J. E., Yoon, K. S., Lee, J. H., Kang, S. B., Lee, J. H., Han, H. S., Rhee, S. H., & Shin, S. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546511413454 · Cited by 229
Autologous platelet rich plasma for arthroscopic rotator cuff repair. A pilot study
Randelli, P. S., Arrigoni, P., Cabitza, P., Volpi, P., & Maffulli, N. (2008) · Disability and Rehabilitation · doi:10.1080/09638280801906081 · Cited by 214 · cited 2×
“‘‘Platelet Rich Plasma and Bone Regeneration: Fact or Fiction?’’ Presented at American Academy of Orthopaedic Surgeons, 2009),(23) acute ligament repair,(35) and tendon repair.(26,37) Interest in these products has become widespread in part because of lay press publicity touting their efficacy in professional athletes.”
BackgroundResultEffects of Platelet Concentrate and a Bone Plug on the Healing of Hamstring Tendons in a Bone Tunnel
Orrego, M., Larrain, C., Rosales, J., Valenzuela, L., Matas, J., Durruty, J., Sudy, H., & Mardones, R. (2008) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2008.07.016 · Cited by 208
Growth Factors for Rotator Cuff Repair
Gulotta, L. V., & Rodeo, S. A. (2009) · Clinics in Sports Medicine · doi:10.1016/j.csm.2008.09.002 · Cited by 196
Accuracy of Conflict-of-Interest Disclosures Reported by Physicians
Okike, K., Kocher, M. S., Wei, E. X., Mehlman, C. T., & Bhandari, M. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0807160 · Cited by 192 · cited 1×
“While not necessarily inferior, a manufacturer’s support of clinical research can generate unwanted bias in any study, as was well documented in a recent review on orthopaedic disclosures of conflict of interest.(6,34) Despite the promise of the basic science, we were unable to demonstrate improvement in perioperative…”
BackgroundPlatelet Rich Plasma in Rotator Cuff Repair
Gamradt, S. C., Rodeo, S. A., & Warren, R. F. (2007) · Techniques in Orthopaedics · doi:10.1097/01.bto.0000261868.03232.dd · Cited by 165 · cited 1×
“Published studies available at the time this study was initiated, as noted, provide little evidence upon which to recommend the use of this product.(19,37) Presented, unpublished material was similarly difficult.”
ResultHan, B., Woodell‐May, J., Ponticiello, M. S., Yang, Z. G., & Nimni, M. E. (2009) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.h.00246 · Cited by 158 · cited 1×
“Thrombin use has been shown to accelerate the release of growth factors and has been shown to significantly decrease the efficacy of PRP in bone grafting.(23) Despite this, the results of the study by Randelli et al(38) using a thrombin-initiated PRP were the most favorable TABLE 3 PRP Augmentation of Rotator Cuff Sur…”
ResultrhBMP-12 Accelerates Healing of Rotator Cuff Repairs in a Sheep Model
Seeherman, H. J., Archambault, J. M., Rodeo, S. A., Turner, A. S., Zekas, L. J., DʼAugusta, D., Li, X. J., Smith, E. A., & Wozney, J. M. (2008) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.g.00742 · Cited by 154
Effects of Platelet-Rich Fibrin Matrix on Repair Integrity of At-Risk Rotator Cuff Tears
Bergeson, A. G., Tashjian, R. Z., Greis, P. E., Crim, J. R., Stoddard, G. J., & Burks, R. T. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546511424402 · Cited by 151
Everts, P. A., Devilee, R. J. J., Brown Mahoney, C., van Erp, A., Oosterbos, C. J. M., Stellenboom, M., Knape, J. T. A., & van Zundert, A. (2008) · European Surgical Research · doi:10.1159/000110862 · Cited by 146
Paoloni, J., Appleyard, R. C., Nelson, J., & Murrell, G. A. C. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504270998 · Cited by 112
The effect of platelet-rich plasma on normal soft tissues in the rabbit
Harris, N. L., Huffer, W. E., von Stade, E., Larson, A. I., Phinney, S., & Purnell, M. L. (2012) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00984 · Cited by 52
Clinical Applications of Bioactive Factors in Sports Medicine: Current Concepts and Future Trends
Angel, M. J., Sgaglione, N. A., & Grande, D. A. (2006) · Sports Medicine and Arthroscopy Review · doi:10.1097/00132585-200609000-00005 · Cited by 26
Cited by
Fernandez, S., DeMarni Cromer, L., Borntrager, C., Swopes, R., Hanson, R. F., & Davis, J. L. (2013) · Clinical Case Studies · doi:10.1177/1534650112462623 · Cited by 427
Mishra, A. K., Skrepnik, N. V., Edwards, S. G., Jones, G. L., Sampson, S., Vermillion, D. A., Ramsey, M. L., Karli, D. C., & Rettig, A. C. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546513494359 · Cited by 396
Kesikburun, S., Tan, A. K., Yılmaz, B., Yaşar, E., & Yazıcıoğlu, K. (2013) · The American Journal of Sports Medicine · doi:10.1177/0363546513496542 · Cited by 301
Chen, X., Jones, I. A., Park, C., & Vangsness, C. T. (2018) · The American Journal of Sports Medicine · doi:10.1177/0363546517743746 · Cited by 294
Retear rates after rotator cuff surgery: a systematic review and meta-analysis
Longo, U. G., Carnevale, A., Piergentili, I., Berton, A., Candela, V., Schena, E., & Denaro, V. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04634-6 · Cited by 240
Metadata
- Authors
- Weber, S. C., Kauffman, J. I., Parise, C., Weber, S. J., & Katz, S. D.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2012-11-30
- Volume
- 41
- Issue
- 2
- Pages
- 263-270
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2323771826
- Cited by
- 194
- References
- 27
- FWCI
- 19.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.