CoChat

Accuracy of Circadian Entrainment under Fluctuating Light Conditions: Contributions of Phase and Period Responses

Beersma, Domien G. M., Daan, Serge, Hut, Roelof A. · 1999 · Journal of Biological Rhythms
Cited by 116

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The accuracy with which a circadian pacemaker can entrain to an environmental 24-h zeitgeber signal depends on (a) characteristics of the entraining signal and (b) response characteristics and intrinsic stability of the pacemaker itself. Position of the sun, weather conditions, shades, and behavioral variations (eye closure, burrowing) all modulate the light signal reaching the pacemaker. A simple model of a circadian pacemaker allows researchers to explore the impact of these factors on pacemaker accuracy. Accuracy is operationally defined as the reciprocal value of the day-to-day standard deviation of the clock times at which a reference phase (0) is reached. For the purpose of this exploration, the authors used a model pacemaker characterized solely by its momentary phase and momentary velocity. The average velocity determines the time needed to complete one pacemaker cycle and, therefore, is inversely proportional to pacemaker period. The model pacemaker responds to light by shifting phase and/or changing its velocity. The authors assumed further that phase and velocity show small random fluctuations and that the velocity is subject to aftereffects. Aftereffects were incorporated mathematically in a term allowing period to contract exponentially to a stable steady-state value, with a time constant of 69 d in the absence of light. The simulations demonstrate that a pacemaker reaches highest accuracy when it responds to light by simultaneous phase shifts and changes of its velocity. Phase delays need to coincide with slowing down and advances with speeding up; otherwise, no synchronization to the zeitgeber occurs. At maximal accuracy, the changes in velocity are such that the average period of the pacemaker under entrained conditions equals 24 h. The results suggest that during entrainment, the pacemaker adjusts its period to 24 h, after which daily phase shifts to compensate for differences between the periods of the zeitgeber and the clock are no longer necessary. On average, phase shifts compensate for maladjustments of phase and velocity changes compensate for maladjustments of period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/074873099129000740

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 116

Metadata

Authors
Beersma, D. G. M., Daan, S., & Hut, R. A.
Venue
Journal of Biological Rhythms
Published
1999-08
Volume
14
Issue
4
Pages
320-329
ISSN
  • 0748-7304 (ISSN-L)
  • 1552-4531
OpenAlex
W2057438898
Cited by
116
References
2
FWCI
2.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Circadian Entrainment under Fluctuating Light Conditions: Contributions of Phase and Period Responses. https://app.cochat.ai/papers/10.1177/074873099129000740
The paper
Beersma, D. G. M., Daan, S., & Hut, R. A. (1999). Accuracy of Circadian Entrainment under Fluctuating Light Conditions: Contributions of Phase and Period Responses. Journal of Biological Rhythms. https://doi.org/10.1177/074873099129000740

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.