Polyurethane Elastomer Biostability
The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Polyurethanes have unique mechanical and biologic properties that make them ideal for many implantable devices. They are subject to some in vivo degradation mechanisms, however. Polyester polyurethanes are subject to hydrolytic degradation and are no longer used in long-term implanted devices. Polyether polyurethanes, while hydrolytically stable, are subject to oxidative degradation in several forms, including environmental stress cracking and metal ion oxidation. Mineralization is also known to occur. A new polycarbonate polyurethane has superior biostability in early in vivo qualification tests compared to the polyether polyurethanes, including no evidence of hydrolysis, ESC or MIO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
CRC Handbook of Chemistry and Physics
P, D. (1992) · Journal of Molecular Structure · doi:10.1016/0022-2860(92)85083-s · Cited by 9,329
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470200123049 · Cited by 1,275
Macrophages and Polymorphonuclear Neutrophils in Lung Defense and Injury
Sibille, Y., & Reynolds, H. Y. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.471 · Cited by 1,083
Photodegradation, photo-oxidation and photostabilization of polymers
J.F.McK. (1976) · Journal of Molecular Structure · doi:10.1016/0022-2860(76)80158-5 · Cited by 735
Inflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591
Self-citationPeppas, N. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90038-x · Cited by 371
Bonart, R. C. (1968) · Journal of Macromolecular Science Part B · doi:10.1080/00222346808212867 · Cited by 363
Lelah, M. D., & Cooper, S. L. (1986) · Medical Entomology and Zoology · Cited by 348
Cited by
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
Santerre, J. P., Woodhouse, K., Laroche, G., & Labow, R. S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.079 · Cited by 718
“gross material oxidation [2,44], MDM-induced degradation [49] and enzyme catalyzed degradation [48].”
BackgroundMethodInfluentialPhotopolymerizable Biomaterials and Light-Based 3D Printing Strategies for Biomedical Applications
Yu, C., Schimelman, J., Wang, P., Miller, K. L., Ma, X., You, S., Guan, J., Sun, B., Zhu, W., & Chen, S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00810 · Cited by 579
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Degradability of Polymers for Implantable Biomedical Devices
Lyu, S., & Untereker, D. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10094033 · Cited by 538
Biodegradable Polyurethanes: Synthesis and Applications in Regenerative Medicine
Guelcher, S. A. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/teb.2007.0133 · Cited by 470
The Mechanical Behavior of Vascular Grafts: A Review
Salacinski, H. J., Goldner, S., Giudiceandrea, A., Hamilton, G., Seifalian, A. M., Edwards, A., & Carson, R. J. (2001) · Journal of Biomaterials Applications · doi:10.1106/na5t-j57a-jtdd-fd04 · Cited by 399
Biomaterials in cardiac tissue engineering: Ten years of research survey
Chen, Q.-Z., Harding, S. E., Ali, N. N., Lyon, A. R., & Boccaccini, A. R. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.08.001 · Cited by 382
Brannigan, R. P., & Dove, A. P. (2017) · Biomaterials Science · doi:10.1039/c6bm00584e · Cited by 334
Compliance properties of conduits used in vascular reconstruction
Tai, N. R., Salacinski, H. J., Edwards, A., Hamilton, G., & Seifalian, A. M. (2000) · Journal of British Surgery · doi:10.1046/j.1365-2168.2000.01566.x · Cited by 267
Polymeric heart valves: new materials, emerging hopes
Ghanbari, H., Viatge, H., Kidane, A. G., Burriesci, G., Tavakoli, M., & Seifalian, A. M. (2009) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.03.002 · Cited by 221
Christenson, E. M., Anderson, J. M., & Hiltner, A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30067 · Cited by 219
Self-citationPoly(carbonate urethane) and poly(ether urethane) biodegradation: In vivo studies
Christenson, E. M., Dadsetan, M., Wiggins, M., Anderson, J. M., & Hiltner, A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30002 · Cited by 185
Self-citationWard, W. K., Slobodzian, E. P., Tiekotter, K. L., & Wood, M. D. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00160-6 · Cited by 176
“Both PUs (PU-S-PEO and PU) used in our study were made with polycarbonate which has been shown to favor biocompatibility in that it limits chronic biodegradation and stress cracking [17,18].”
MethodA novel nanocomposite polymer for development of synthetic heart valve leaflets
Kidane, A. G., Burriesci, G., Edirisinghe, M., Ghanbari, H., Bonhoeffer, P., & Seifalian, A. M. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.02.025 · Cited by 175
“Previous studies have shown that polyester PUs were not suitable for long-term implants due to their poor hydrolytic stability [12].”
BackgroundIn Vivo Applications of Electrospun Tissue-Engineered Vascular Grafts: A Review
Rocco, K. A., Maxfield, M. W., Best, C. A., Dean, E. W., & Breuer, C. K. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0123 · Cited by 165
“61,69 The discovery of in vivo degradation mechanisms presumably shifted interest away from these polyurethanes as permanent synthetic vascular grafts and toward their usage as TEVGs that can be tailored with a more controlled degradation profile.”
Rational design of biodegradable thermoplastic polyurethanes for tissue repair
Xu, C., & Hong, Y. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.11.029 · Cited by 109
“Poly(ester urethane)s are biodegradable in vivo and highly elastic [248].”
BackgroundHydrolytic degradation of poly(carbonate)-urethanes by monocyte-derived macrophages
Labow, R. S., Meek, E., & Santerre, J. P. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00049-7 · Cited by 108
Biomedical Applications of Nondegradable Polymers
Subramaniam, A., & Sethuraman, S. (2014) · Natural and Synthetic Biomedical Polymers · doi:10.1016/b978-0-12-396983-5.00019-3 · Cited by 75
Macrophage behavior on surface-modified polyurethanes
Jones, J. A., Dadsetan, M., Collier, T. O., Ebert, M., Stokes, K. S., Ward, R. S., Hiltner, P. A., & Anderson, J. M. (2004) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856204323046843 · Cited by 70
Self-citationMatheson, L. A., Labow, R. S., & Santerre, J. P. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10286 · Cited by 69
Antioxidant inhibition of poly(carbonate urethane) in vivo biodegradation
Christenson, E. M., Anderson, J. M., & Hiltner, A. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30506 · Cited by 64
Self-citation
Metadata
- Authors
- Stokes, K., McVenes, R., & Anderson, J. M.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 1995-04
- Volume
- 9
- Issue
- 4
- Pages
- 321-354
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W1598825449
- Cited by
- 366
- References
- 43
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.