The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Polyurethane Elastomer Biostability
Abstract
Polyurethanes have unique mechanical and biologic properties that make them ideal for many implantable devices. They are subject to some in vivo degradation mechanisms, however. Polyester polyurethanes are subject to hydrolytic degradation and are no longer used in long-term implanted devices. Polyether polyurethanes, while hydrolytically stable, are subject to oxidative degradation in several forms, including environmental stress cracking and metal ion oxidation. Mineralization is also known to occur. A new polycarbonate polyurethane has superior biostability in early in vivo qualification tests compared to the polyether polyurethanes, including no evidence of hydrolysis, ESC or MIO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
CRC Handbook of Chemistry and Physics
P, D. (1992) · Journal of Molecular Structure · doi:10.1016/0022-2860(92)85083-s · Cited by 9,329
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470200123049 · Cited by 1,275
Macrophages and Polymorphonuclear Neutrophils in Lung Defense and Injury
Sibille, Y., & Reynolds, H. Y. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.471 · Cited by 1,083
Photodegradation, photo-oxidation and photostabilization of polymers
J.F.McK. (1976) · Journal of Molecular Structure · doi:10.1016/0022-2860(76)80158-5 · Cited by 735
Inflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591
Self-citationPeppas, N. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90038-x · Cited by 371
Bonart, R. C. (1968) · Journal of Macromolecular Science Part B · doi:10.1080/00222346808212867 · Cited by 363
Lelah, M. D., & Cooper, S. L. (1986) · Medical Entomology and Zoology · Cited by 348
Biodegradable Polymers and Plastics
(2003) · Springer eBooks · doi:10.1007/978-1-4419-9240-6 · Cited by 337
Chapter 4 Mechanisms of inflammation and infection with implanted devices
Anderson, J. M. (1993) · Cardiovascular Pathology · doi:10.1016/1054-8807(93)90045-4 · Cited by 331
Self-citationZhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318
Self-citationBiodegradable Polymers and Plastics
(2004) · Chemistry International -- Newsmagazine for IUPAC · doi:10.1515/ci.2004.26.2.30b · Cited by 293
Polyurethanes in Biomedical Engineering
Egbers, G., & Planck, H. (1984) · Cited by 212
Biomaterial-associated calcification: pathology, mechanisms, and strategies for prevention.
Schöen, F. J., Harasaki, H., Kim, K. M., Anderson, H. C., & Levy, R. J. (1988) · PubMed · Cited by 200
Biodegradation of a polyurethane in vitro
Phua, S. K., Castillo, E., Anderson, J. M., & Hiltner, A. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210207 · Cited by 172
Self-citationCellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80A
Zhao, Q., Agger, M. P., Fitzpatrick, M. N., Anderson, J. M., Hiltner, A., Stokes, K., & Urbanski, P. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240508 · Cited by 158
Self-citationGijsman, P. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-3455-3.00023-7 · Cited by 153
Degradation of biomaterials by phagocyte-derived oxidants.
Sutherland, K., Mahoney, J. R., Coury, A. J., & Eaton, J. W. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116841 · Cited by 147
Zhao, Q. H., McNally, A. K., Rubin, K. R., Renier, M., Wu, Y., Rose‐Caprara, V., Anderson, J. M., Hiltner, A., Urbanski, P., & Stokes, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270311 · Cited by 140
Self-citationAnalysis of in vitro enzymatic and oxidative degradation of polyurethanes
Ratner, B. D., Gladhill, K. W., & Horbett, T. A. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820220607 · Cited by 136
An FTIR–ATR investigation of in vivo poly(ether urethane) degradation
Wu, Y., Sellitti, C., Anderson, J. M., Hiltner, A., Lodoen, G. A., & Payet, C. R. (1992) · Journal of Applied Polymer Science · doi:10.1002/app.1992.070460202 · Cited by 120
Self-citationPolyether polyurethanes for implantable pacemaker leads
Stokes, K., & COBIAN, K. E. (1982) · Biomaterials · doi:10.1016/0142-9612(82)90024-2 · Cited by 117
Self-citationThe biodegradation of poly(ether urethanes)
Smith, R., Williams, D. F., & Oliver, C. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210908 · Cited by 111
The in vivo auto-oxidation of polyether polyurethane by metal ions
Stokes, K., Urbanski, P., & UPTON, J. E. (1989) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856290x00062 · Cited by 106
Self-citationPolyether Polyurethanes: Biostable or Not?
Stokes, K. (1988) · Journal of Biomaterials Applications · doi:10.1177/088532828800300205 · Cited by 103
Self-citationMicromechanics of fracture in elastomers
Gent, A. N., & Pulford, C. T. R. (1984) · Journal of Materials Science · doi:10.1007/bf02396933 · Cited by 95
Calcification of cardiac valve bioprostheses
Fishbein, M. C., Levy, R. J., Ferrans, V. J., Dearden, L. C., Nashef, A., Goodman, A. P., & Carpentier, A. (1982) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)37251-4 · Cited by 91
Surface and bulk characteristics of a polyether urethane for artificial hearts
BORETOS, J. W., Pierce, W. S., Baier, R. E., LeRoy, A. F., & Donachy, H. J. (1975) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820090308 · Cited by 89
Toxic hydrolysis product from a biodegradable foam implant
Batich, C. D., Williams, J., & King, R. W. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820231406 · Cited by 80
Szycher, M., & Siciliano, A. A. (1991) · Journal of Biomaterials Applications · doi:10.1177/088532829100500404 · Cited by 70
Degradable materials: Perspectives, issues and opportunities
Mikos, A. G. (1991) · Journal of Controlled Release · doi:10.1016/0168-3659(91)90062-i · Cited by 69
Effect of some additives on the biostability of a poly(etherurethane) elastomer
Wu, Y. X., Zhao, Q., Anderson, J. M., Hiltner, A., Lodoen, G. A., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250604 · Cited by 61
Self-citationDegradable materials: perspectives, issues, and opportunities
(1991) · Additives for Polymers · doi:10.1016/0306-3747(91)90054-p · Cited by 60
Biodegradation of polyethylene foils by bacterial and liver homogenates
Wasserbauer, R., Beranová, M., Vančurová, D., & Doležel, B. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90049-v · Cited by 45
POLYURETHANE AORTAS IN DOGS. THREE-YEAR RESULTS
MIRKOVITCH, V., Akutsu, T., & Kolff, W. J. (1962) · ASAIO Journal · doi:10.1097/00002480-196204000-00018 · Cited by 45
Development of block copolyether‐urethane intra‐aortic balloons and other medical devices
Brash, J. L., Fritzinger, B. K., & Bruck, S. D. (1973) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820070405 · Cited by 44
Beranová, M., Wasserbauer, R., Vančurová, D., Štifter, M., Očenášková, J., & Mára, M. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90070-7 · Cited by 39
Amin, P., Wille, J. J., Shah, K. R., & Kydonieus, A. F. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270513 · Cited by 23
Creep of a poly(etherurethane urea) in an oxidative environment
Wu, Y.-T., Lodoen, G. A., Anderson, J. M., Baer, E., & Hiltner, A. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280414 · Cited by 21
Self-citationIonic Interactions of Polyurethanes
Thoma, R. J., Tan, F. R., & Phillips, R. E. (1988) · Journal of Biomaterials Applications · doi:10.1177/088532828800300203 · Cited by 21
Metal Catalyzed Oxidative Degradation of Implanted Polyurethane Devices
Stokes, K., Berthelson, W. A., & Davis, M. W. (1987) · Springer eBooks · doi:10.1007/978-1-4613-1829-3_17 · Cited by 17
Self-citation
Cited by
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
Santerre, J. P., Woodhouse, K., Laroche, G., & Labow, R. S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.079 · Cited by 718
Photopolymerizable Biomaterials and Light-Based 3D Printing Strategies for Biomedical Applications
Yu, C., Schimelman, J., Wang, P., Miller, K. L., Ma, X., You, S., Guan, J., Sun, B., Zhu, W., & Chen, S. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00810 · Cited by 579
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Degradability of Polymers for Implantable Biomedical Devices
Lyu, S., & Untereker, D. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10094033 · Cited by 538
Metadata
- Authors
- Stokes, K., McVenes, R., & Anderson, J. M.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 1995-04
- Volume
- 9
- Issue
- 4
- Pages
- 321-354
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W1598825449
- Cited by
- 366
- References
- 43
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.