Implant Surfaces and Interface Processes
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
The past decades and current R&D of biomaterials and medical implants show some general trends. One major trend is an increased degree of functionalization of the material surface, better to meet the demands of the biological host system. While the biomaterials of the past and those in current use are essentially bulk materials (metals, ceramics, polymers) or special compounds (bioglasses), possibly with some additional coating (e.g., hydroxyapatite), the current R&D on surface modifications points toward much more complex and multifunctional surfaces for the future. Such surface modifications can be divided into three classes, one aiming toward an optimized three-dimensional physical micro-architecture of the surface (pore size distributions, "roughness", etc.), the second one focusing on the (bio) chemical properties of surface coatings and impregnations (ion release, multi-layer coatings, coatings with biomolecules, controlled drug release, etc.), and the third one dealing with the viscoelastic properties (or more generally the micromechanical properties) of material surfaces. These properties are expected to affect the interfacial processes cooperatively, i.e., there are likely synergistic effects between and among them: The surface is "recognized" by the biological system through the combined chemical and topographic pattern of the surface, and the viscoelastic properties. In this presentation, the development indicated above is discussed briefly, and current R&D in this area is illustrated with a number of examples from our own research. The latter include micro- and nanofabrication of surface patterns and topographies by the use of laser machining, photolithographic techniques, and electron beam and colloidal lithographies to produce controlled structures on implant surfaces in the size range 10 nm to 100 μm. Examples of biochemical modifications include mono- or lipid membranes and protein coatings on different surfaces. A new method to evaluate, e.g., biomaterial-protein and biomaterial-cell interactions-the Quartz Crystal Microbalance-is described briefly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The interaction of water with solid surfaces: Fundamental aspects
Thiel, P. A., & Madey, T. E. (1987) · Surface Science Reports · doi:10.1016/0167-5729(87)90001-x · Cited by 2,411
Supported Membranes: Scientific and Practical Applications
Sackmann, E. (1996) · Science · doi:10.1126/science.271.5245.43 · Cited by 2,151
Structure and reactivity of water at biomaterial surfaces
Vogler, E. A. (1998) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(97)00040-7 · Cited by 1,640
Nanosphere lithography: A materials general fabrication process for periodic particle array surfaces
Hulteen, J. C., & Van Duyne, R. P. (1995) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.579726 · Cited by 1,465
Role of hydration and water structure in biological and colloidal interactions
Israelachvili, J., & Wennerström, H. (1996) · Nature · doi:10.1038/379219a0 · Cited by 1,364
Rodahl, M., Höök, F., Krozer, A., Brzezinski, P., & Kasemo, B. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145396 · Cited by 1,296
Self-citationSurface Specific Kinetics of Lipid Vesicle Adsorption Measured with a Quartz Crystal Microbalance
Keller, C. A., & Kasemo, B. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74057-3 · Cited by 1,010
Self-citationTotal Internal Reflection Fluorescence
Axelrod, D., Burghardt, T. P., & Thompson, N. L. (1984) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.13.060184.001335 · Cited by 741
Höök, F., Rodahl, M., Brzezinski, P., & Kasemo, B. (1998) · Langmuir · doi:10.1021/la970815u · Cited by 724
Self-citationThe Kinoform: A New Wavefront Reconstruction Device
Lesem, L. B., Hirsch, P. M., & Jordan, J. A. (1969) · IBM Journal of Research and Development · doi:10.1147/rd.132.0150 · Cited by 596
Proteins at Interfaces II: Fundamentals and Applications
(1995) · ACS Symposium Series · doi:10.1021/bk-1995-0602 · Cited by 555
Biocompatibility of titanium implants: Surface science aspects
Kasemo, B. (1983) · The Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(83)90359-1 · Cited by 534
Self-citationProtein adsorption on solid surfaces
Hlady, V., & Buijs, J. (1996) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(96)80098-x · Cited by 522
Höök, F., Rodahl, M., Kasemo, B., & Brzezinski, P. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.21.12271 · Cited by 483
Self-citationThe interface zone of inorganic implantsIn vivo: Titanium implants in bone
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., Kasemo, B., Larsson, K., Lundström, I., McQueen, D. H., & Skalak, R. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363944 · Cited by 436
Self-citationAn evaluation of variables influencing implant fixation by direct bone apposition
Thomas, K. A., & Cook, S. D. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190802 · Cited by 313
Protein absorption and ellipsometry in biomaterial research
Elwing, H. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00112-9 · Cited by 298
Effects of substratum morphology on cell physiology
Singhvi, R., Stephanopoulos, G., & Wang, D. I. C. (1994) · Biotechnology and Bioengineering · doi:10.1002/bit.260430811 · Cited by 285
Driving forces for protein adsorption at solid surfaces
Norde, W. (1996) · Macromolecular Symposia · doi:10.1002/masy.19961030104 · Cited by 243
The Piezoelectric Quartz Crystal Mass and Dissipation Sensor: A Means of Studying Cell Adhesion
Fredriksson, C., Kihlman, S., Rodahl, M., & Kasemo, B. (1998) · Langmuir · doi:10.1021/la971005l · Cited by 242
Self-citationKasemo, B., & Lausmaa, J. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820221307 · Cited by 237
Self-citationChehroudi, B., Gould, T. R. L., & Brunette, D. M. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240906 · Cited by 208
Tengvall, P., Lundström, I., & Liedberg, B. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00110-5 · Cited by 187
Surface science aspects on inorganic biomaterials
Kasemo, B., & Lausmaa, J. (1986) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 181
Self-citationThe engineering of biomaterials exhibiting recognition and specificity
Ratner, B. D. (1996) · Journal of Molecular Recognition · doi:10.1002/(sici)1099-1352(199634/12)9:5/6<617::aid-jmr310>3.0.co;2-d · Cited by 169
Models of protein adsorption on solid surfaces
Lundström, I. (2007) · Steinkopff eBooks · doi:10.1007/bfb0114308 · Cited by 152
Comparison of the QCM and the SPR method for surface studies and immunological applications
Köβlinger, C., Uttenthaler, E., Drost, S., Aberl, F., Wolf, H. J., Brink, G., Stanglmaier, A., & Sackmann, E. (1995) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(95)85023-6 · Cited by 141
Inoue, T., COX, J. E., Pilliar, R. M., & Melcher, A. H. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210114 · Cited by 138
Höök, F., Rodahl, M., Brzezinski, P., & Kasemo, B. (1998) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5774 · Cited by 126
Self-citationVariation in contact guidance by human cells on a microstructured surface
Meyle, J., Gültig, K., & Nisch, W. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290112 · Cited by 121
Recognition of artificial microstructures by sensory nerve fibers in culture
Hirono, T., Torimitsu, K., Kawana, A., & Fukuda, J. (1988) · Brain Research · doi:10.1016/0006-8993(88)91314-5 · Cited by 79
Nanometer molecular lithography
Douglas, K., Clark, N. A., & Rothschild, K. J. (1986) · Applied Physics Letters · doi:10.1063/1.96741 · Cited by 79
Nanofabricated model catalysts. Manufacturing and model studies
Wong, K. L., Johansson, S., & Kasemo, B. (1996) · Faraday Discussions · doi:10.1039/fd9960500237 · Cited by 75
Self-citationYan, S. R., Fumagalli, L., Dusi, S., & Berton, G. (1995) · Journal of Leukocyte Biology · doi:10.1002/jlb.58.5.595 · Cited by 61
Nakayama, Y., & Matsuda, T. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291017 · Cited by 44
ChemInform Abstract: Protein Adsorption and Ellipsometry in Biomaterial Research
Elwing, H. B. (1998) · ChemInform · doi:10.1002/chin.199837340 · Cited by 22
Cited by
Interpretation of Protein Adsorption: Surface-Induced Conformational Changes
Roach, P., Farrar, D., & Perry, C. C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja042898o · Cited by 1,479
Kasemo, B. (2002) · Surface Science · doi:10.1016/s0039-6028(01)01809-x · Cited by 1,079
Self-citationOxygen Vacancies as Active Sites for Water Dissociation on RutileTiO2(110)
Schaub, R., Thostrup, P., Lopez, N., Lægsgaard, E., Stensgaard, I., Nørskov, J. K., & Besenbacher, F. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.266104 · Cited by 997
Modern biomaterials: a review—bulk properties and implications of surface modifications
Roach, P., Eglin, D., Rohde, K., & Perry, C. C. (2007) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-006-0064-3 · Cited by 562
Effects of topography and composition of titanium surface oxides on osteoblast responses
Zhu, X., Chen, J., Scheideler, L., Reichl, R., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.011 · Cited by 534
Metadata
- Authors
- Kasemo, B., & Gold, J.
- Venue
- Advances in Dental Research
- Publisher
- SAGE Publications
- Published
- 1999-06
- Volume
- 13
- Issue
- 1
- Pages
- 8-20
- ISSN
- 0895-9374 (ISSN-L)
- 1544-0737
- OpenAlex
- W1997363501
- Cited by
- 317
- References
- 36
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.