Improving Accessibility of the Impedance-Based Structural Health Monitoring Method
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper presents current research on impedance-based structural health monitoring technique. The basic principle behind this technique is to apply high-frequency structural excitations (typically higher than 30 kHz) through the surface-bonded piezoelectric transducers, and measure the impedance of structures by monitoring the current and voltage applied to the piezoelectric transducers. Changes in impedance indicate changes in the structure, which in turn can indicate that damage has occurred. Three examples, including a bolted joint, gas pipeline, and composite structure, are presented to illustrate the effectiveness of this health monitoring technique to a wide variety of practical field applications. Although many proof-of-concept experiments have been performed using the impedance methods, the impedance-measuring device (HP4194A) is still bulky and expensive. Therefore, an operational amplifier-based turnkey device that can measure and record the electric impedance of a PZT has been developed. The performance of this miniaturized and portable device has been compared to our previous results and its effectiveness has been demonstrated. This paper summarizes the experimental setup, procedures, and considerations needed to implement the device in field applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liang, C., Sun, F. P., & Rogers, C. A. (1994) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9400500102 · Cited by 790
Impedance-Based Health Monitoring of Civil Structural Components
Park, G., Cudney, H. H., & Inman, D. J. (2000) · Journal of Infrastructure Systems · doi:10.1061/(asce)1076-0342(2000)6:4(153 · Cited by 460
Self-citationImpedance-Based Structural Health Monitoring for Temperature Varying Applications.
PARK, G., KABEYA, K., CUDNEY, H. H., & INMAN, D. J. (1999) · JSME International Journal Series A · doi:10.1299/jsmea.42.249 · Cited by 284
Self-citationImpedance-Based Structural Health Monitoring with Artificial Neural Networks
Lopes, V., Park, G., Cudney, H. H., & Inman, D. J. (2000) · Journal of Intelligent Material Systems and Structures · doi:10.1106/h0ev-7pwm-qyhw-e7vf · Cited by 142
Self-citation
Cited by
Overview of Piezoelectric Impedance-Based Health Monitoring and Path Forward
Park, G., Sohn, H., Farrar, C. R., & Inman, D. J. (2003) · The Shock and Vibration Digest · doi:10.1177/05831024030356001 · Cited by 1,060
Self-citationStructural health monitoring for a wind turbine system: a review of damage detection methods
Ciang, C. C., Lee, J.-R., & Bang, H.-J. (2008) · Measurement Science and Technology · doi:10.1088/0957-0233/19/12/122001 · Cited by 802
Sodano, H. A., Park, G., & Inman, D. J. (2004) · Mechanical Systems and Signal Processing · doi:10.1016/s0888-3270(03)00081-5 · Cited by 363
Self-citationNa, W. S., & Baek, J. (2018) · Sensors · doi:10.3390/s18051307 · Cited by 336
Martinez-Luengo, M., Kolios, A., & Wang, L. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.05.085 · Cited by 310
Baptista, F., Budoya, D., Almeida, V., & Ulson, J. (2014) · Sensors · doi:10.3390/s140101208 · Cited by 286
Structural Damage Detection Using a Minimum Rank Update Theory
Zimmerman, D. C., & Kaouk, M. (1994) · Journal of Vibration and Acoustics · doi:10.1115/1.2930416 · Cited by 265
Structural health monitoring using piezoelectric impedance measurements
Park, G., & Inman, D. J. (2007) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2006.1934 · Cited by 220
“…Los Alamos National Laboratory, Los Alamos, NM 87545, USA 2Centre for Intelligent Material Systems and Structures, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061-0261, USA This paper presents an overview and recent advances in impedance-based structural health monitoring.”
BackgroundSelf-citationAnnamdas, V. G. M., & Soh, C. K. (2010) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x09352816 · Cited by 218
“This was again a step ahead of previously developed strain measuring technique (Peairs et al., 2004a,b).”
A comprehensive review of loosening detection methods for threaded fasteners
Huang, J., Liu, J., Gong, H., & Deng, X. (2022) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.108652 · Cited by 177
Annamdas, V. G., & Radhika, M. A. (2013) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x13481254 · Cited by 176
“Peairs et al. (2004) developed a novel low-cost and portable version of impedance analyzer, the major hardware used in the EMI technique, paving the way for cost reduction of hardware.”
MethodStructural health monitoring of underground facilities – Technological issues and challenges
Bhalla, S., Yang, Y. W., Zhao, J., & Soh, C. K. (2005) · Tunnelling and Underground Space Technology · doi:10.1016/j.tust.2005.03.003 · Cited by 170
Tapping and listening: a new approach to bolt looseness monitoring
Kong, Q., Zhu, J., Ho, S. C. M., & Song, G. (2018) · Smart Materials and Structures · doi:10.1088/1361-665x/aac962 · Cited by 164
Antunes, R. A., Cortez, N. E., Gianesini, B. M., & Vieira Filho, J. (2019) · Sensors · doi:10.3390/s19122802 · Cited by 34
Metadata
- Authors
- Peairs, D. M., Park, G., & Inman, D. J.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2004-02
- Volume
- 15
- Issue
- 2
- Pages
- 129-139
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2026081515
- Cited by
- 278
- References
- 4
- FWCI
- 23.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.