Structural Health Monitoring in mainland China: Review and Future Trends
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Structural health monitoring (SHM) technology has been successfully applied to understand the loads, environment actions, and behaviors of a structure subjected to various actions through solving a reverse problem. The sensing technology is a critical part of SHM. In this article, the development of advanced sensing technology and sensors in mainland China in the past decade, such as optic fiber sensing technology, wave propagation-based piezoelectric ceramic (PZT) sensing technology, smart cement-based sensing technology, and corrosion detection technology, have been critically reviewed. In addition, the article also summarizes the application of SHM technologies in earthquake engineering, wind engineering and life-cycle performance evaluation and corresponding progress achieved in mainland China. The challenges and future trends in the development of sensing technology and SHM are put forward in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent applications of fiber optic sensors to health monitoring in civil engineering
Li, H.-N., Li, D.-S., & Song, G.-B. (2004) · Engineering Structures · doi:10.1016/j.engstruct.2004.05.018 · Cited by 897
Self-citationPiezoresistive Cement-based Strain Sensors and Self-sensing Concrete Components
Ou, J., & Han, B. (2008) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x08094190 · Cited by 174
Self-citationCorrosion monitoring of reinforcing steel in cement mortar by EIS and ENA
Qiao, G., & Ou, J. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2007.06.070 · Cited by 158
Self-citationApplications of optical fibre Bragg gratings sensing technology-based smart stay cables
Li, H., Ou, J., & Zhou, Z. (2009) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2009.04.016 · Cited by 124
Self-citationLi, H., XIAO, H., & OU, J. (2008) · Composites Science and Technology · doi:10.1016/j.compscitech.2008.03.007 · Cited by 107
Self-citationHan, B., Yu, Y. P., Han, B., & Ou, J. (2008) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2008.06.021 · Cited by 87
Self-citationTraffic load modelling based on structural health monitoring data
Lan, C., Li, H., & Ou, J. (2009) · Structure and Infrastructure Engineering · doi:10.1080/15732470902726809 · Cited by 52
Self-citation
Cited by
Fiber-Reinforced Polymer Composites: Manufacturing, Properties, and Applications
Rajak, D., Pagar, D., Menezes, P., & Linul, E. (2019) · Polymers · doi:10.3390/polym11101667 · Cited by 1,706
Advances in Computer Vision-Based Civil Infrastructure Inspection and Monitoring
Spencer, B. F., Hoskere, V., & Narazaki, Y. (2019) · Engineering · doi:10.1016/j.eng.2018.11.030 · Cited by 1,282
A New Frontier of Printed Electronics: Flexible Hybrid Electronics
Khan, Y., Thielens, A., Muin, S., Ting, J., Baumbauer, C., & Arias, A. C. (2020) · Advanced Materials · doi:10.1002/adma.201905279 · Cited by 891
Structural Health Monitoring Using Wireless Sensor Networks: A Comprehensive Survey
Noel, A. B., Abdaoui, A., Elfouly, T., Ahmed, M. H., Badawy, A., & Shehata, M. S. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2691551 · Cited by 489
The State of the Art of Data Science and Engineering in Structural Health Monitoring
Bao, Y., Chen, Z., Wei, S., Xu, Y., Tang, Z., & Li, H. (2019) · Engineering · doi:10.1016/j.eng.2018.11.027 · Cited by 483
Self-citationDamage detection techniques for wind turbine blades: A review
Du, Y., Zhou, S., Jing, X., Peng, Y., Wu, H., & Kwok, N. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.106445 · Cited by 463
Predictive Maintenance and Intelligent Sensors in Smart Factory: Review
Pech, M., Vrchota, J., & Bednář, J. (2021) · Sensors · doi:10.3390/s21041470 · Cited by 461
Abdulkarem, M., Samsudin, K., Rokhani, F. Z., & A Rasid, M. F. (2020) · Structural Health Monitoring · doi:10.1177/1475921719854528 · Cited by 424
A review on five key sensors for monitoring of concrete structures
Taheri, S. (2019) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2019.01.172 · Cited by 311
Liu, Y., Nie, X., Fan, J., & Liu, X. (2020) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12501 · Cited by 305
Fault Diagnosis for Electrical Systems and Power Networks: A Review
Furse, C. M., Kafal, M., Razzaghi, R., & Shin, Y.-J. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2987321 · Cited by 296
The state of the art in structural health monitoring of cable-stayed bridges
Li, H., & Ou, J. (2016) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-015-0115-x · Cited by 267
Self-citationStructural health monitoring methods of cables in cable-stayed bridge: A review
Zhang, L., Qiu, G., & Chen, Z. (2021) · Measurement · doi:10.1016/j.measurement.2020.108343 · Cited by 235
Yan, W.-J., Zhao, M.-Y., Sun, Q., & Ren, W.-X. (2019) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.06.053 · Cited by 216
Tang, Y., Zhao, Z., Hu, H., Liu, Y., Wang, X., Zhou, S., & Qiu, J. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b09314 · Cited by 209
Improving the durability of the optical fiber sensor based on strain transfer analysis
Wang, H., Jiang, L., & Xiang, P. (2018) · Optical Fiber Technology · doi:10.1016/j.yofte.2018.02.004 · Cited by 201
“To characterize the structural performance, structural health monitoring (SHM) technology has been recognized as one of the most effective and intelligent measures [18,19,1,23,22,10,7].”
BackgroundStructural damage identification using damping: a compendium of uses and features
Cao, M. S., Sha, G. G., Gao, Y. F., & Ostachowicz, W. (2017) · Smart Materials and Structures · doi:10.1088/1361-665x/aa550a · Cited by 196
Structural health monitoring research under varying temperature condition: a review
Han, Q., Ma, Q., Xu, J., & Liu, M. (2021) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-020-00444-x · Cited by 190
Computational methodologies for optimal sensor placement in structural health monitoring: A review
Tan, Y., & Zhang, L. (2020) · Structural Health Monitoring · doi:10.1177/1475921719877579 · Cited by 186
Mao, J.-X., Wang, H., Feng, D.-M., Tao, T.-Y., & Zheng, W.-Z. (2018) · Structural Control and Health Monitoring · doi:10.1002/stc.2146 · Cited by 163
Dong, W., Li, W., Zhu, X., Sheng, D., & Shah, S. P. (2021) · Cement and Concrete Composites · doi:10.1016/j.cemconcomp.2021.103962 · Cited by 139
Chen, Z., Zhou, X., Wang, X., Dong, L., & Qian, Y. (2017) · Sensors · doi:10.3390/s17092151 · Cited by 128
Huang, Y., Beck, J. L., & Li, H. (2017) · Structural Safety · doi:10.1016/j.strusafe.2016.09.001 · Cited by 111
Self-citationLi, S., Laima, S., & Li, H. (2017) · Engineering Structures · doi:10.1016/j.engstruct.2017.02.024 · Cited by 96
Self-citationHIERARCHICAL SPARSE BAYESIAN LEARNING FOR STRUCUTRAL HEALTH MONITORING WITH INCOMPLETE MODAL DATA
Huang, Y., & Beck, J. L. (2015) · International Journal for Uncertainty Quantification · doi:10.1615/int.j.uncertaintyquantification.2015011808 · Cited by 87
Mustapha, S., Lu, Y., Ng, C.-T., & Malinowski, P. (2021) · Vibration · doi:10.3390/vibration4030033 · Cited by 84
“…contribute to the selection process of a sensor node including, but not exclusively, the application, operational environment, the measurement type (strain, vibration, temperature, ultrasonic, etc.), sensor size and range, power consumption, robustness, and the lifetime of the sensing element [4].”
BackgroundInfluentialEmerging data technology in structural health monitoring: compressive sensing technology
Bao, Y., Li, H., & Ou, J. (2014) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-013-0064-1 · Cited by 43
Self-citationHigh-throughput design of fiber reinforced cement-based composites using deep learning
Tong, Z., Huo, J., & Wang, Z. (2020) · Cement and Concrete Composites · doi:10.1016/j.cemconcomp.2020.103716 · Cited by 39
Antunes, R. A., Cortez, N. E., Gianesini, B. M., & Vieira Filho, J. (2019) · Sensors · doi:10.3390/s19122802 · Cited by 34
Zhang, W.-H., Qin, J., Lu, D.-G., Liu, M., & Faber, M. H. (2023) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2022.109916 · Cited by 22
Carani, L. B., Eze, V. O., Iwuagwu, C., & Okoli, O. I. (2020) · Journal of Composites Science · doi:10.3390/jcs4040190 · Cited by 12
Metadata
- Authors
- Ou, J., & Li, H.
- Venue
- Structural Health Monitoring
- Publisher
- SAGE Publications
- Published
- 2010-03-16
- Volume
- 9
- Issue
- 3
- Pages
- 219-231
- ISSN
- 1475-9217 (ISSN-L)
- 1741-3168
- OpenAlex
- W2139892018
- Cited by
- 525
- References
- 7
- FWCI
- 36.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.