Analysis, Modeling, and Simulation of the Accuracy of Continuous Glucose Sensors

Open access
Breton, Marc, Kovatchev, Boris · 2008 · Journal of Diabetes Science and Technology
Cited by 173

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Continuous glucose monitors (CGMs) collect a detailed time series of consecutive observations of the underlying process of glucose fluctuations. To some extent, however, the high temporal resolution of the data is accompanied by increased probability of error in any single data point. Due to both physiological and technical reasons, the structure of these errors is complex and their analysis is not straightforward. In this article, we describe some of the methods needed to obtain a description of the sensor error that is detailed enough for simulation. Methods: Data were provided by Abbott Diabetes Care and included two data sets collected by the FreeStyle Navigator™ CGM: The first set consisted of 1032 time series of glucose readings from 136 patients with type 1 diabetes and parallel time series of reference blood glucose (BG) collected via self-monitoring at irregular intervals. The average duration of a time series was 5 days; the total number of sensor-reference data pairs was approximately 20,600. The second data set consisted of 56 time series of glucose readings from 28 patients with type 1 diabetes and a parallel time series of reference BG measured via the YSI 2300 Stat Plus™ analyzer every 15 minutes. The average duration of a time series was 2 days; the total number of sensor-reference data pairs was approximately 7000. Results: Three sets of results are discussed: analysis of sensor errors with respect to the BG rate of change, mathematical modeling of sensor error patterns and distribution, and computer simulation of sensor errors: Sensor errors depend nonlinearly on the BG rate of change: Errors tend to be positive (high readings) when the BG rate of change is negative and negative (low readings) when the BG rate of change is positive, which is indicative of an underlying time delay. In addition, the sensor noise is non-white (non-Gaussian) and the consecutive sensor errors are highly interdependent. Thus, the modeling of sensor errors is based on a diffusion model of blood-to-interstitial glucose transport, which accounts for the time delay, and a time-series approach, which includes autoregressive moving average (ARMA) noise to account for the interdependence of consecutive sensor errors. Based on modeling, we have developed a computer simulator of sensor errors that includes both generic and sensor-specific error components. A χ 2 test showed that no significant difference exists between the observed and the simulated distribution of sensor errors and the distribution of errors of the FreeStyle Navigator ( p > .46). Conclusions: CGM accuracy was modeled via diffusion and additive ARMA noise, which allowed for designing a computer simulator of sensor errors. The simulator, a component of a larger simulation platform approved by the Food and Drug Administration in January 2008 for pre-clinical testing of closed-loop strategies, has been successfully applied to in silico testing of closed-loop control algorithms, resulting in an investigational device exemption for closed-loop trials at the University of Virginia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229680800200517

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 173

Metadata

Authors
Breton, M., & Kovatchev, B.
Venue
Journal of Diabetes Science and Technology
Published
2008-09
Volume
2
Issue
5
Pages
853-862
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2123628675
Cited by
173
References
4
FWCI
6.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis, Modeling, and Simulation of the Accuracy of Continuous Glucose Sensors. https://app.cochat.ai/papers/10.1177/193229680800200517
The paper
Breton, M., & Kovatchev, B. (2008). Analysis, Modeling, and Simulation of the Accuracy of Continuous Glucose Sensors. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680800200517

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.