GIM, Simulation Software of Meal Glucose–Insulin Model

Open access
Dalla Man, Chiara, Raimondo, Davide M., Rizza, Robert A., Cobelli, Claudio·2007·Journal of Diabetes Science and Technology

Abstract

BACKGROUND: A simulation model of the glucose-insulin system in normal life conditions can be very useful in diabetes research, e.g., testing insulin infusion algorithms and decision support systems and assessing glucose sensor performance and patient and student training. A new meal simulation model has been proposed that incorporates state-of-the-art quantitative knowledge on glucose metabolism and its control by insulin at both organ/tissue and whole-body levels. This article presents the interactive simulation software GIM (glucose insulin model), which implements this model. METHODS: The model is implemented in MATLAB, version 7.0.1, and is designed with a windows interface that allows the user to easily simulate a 24-hour daily life of a normal, type 2, or type 1 diabetic subject. A Simulink version is also available. Three meals a day are considered. Both open- and closed-loop controls are available for simulating a type 1 diabetic subject. RESULTS: Software options are described in detail. Case studies are presented to illustrate the potential of the software, e.g., compare a normal subject vs an insulin-resistant subject or open-loop vs closed-loop insulin infusion in type 1 diabetes treatment. CONCLUSIONS: User-friendly software that implements a state-of-the-art physiological model of the glucose-insulin system during a meal has been presented. The GIM graphical interface makes its use extremely easy for investigators without specific expertise in modeling.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229680700100303

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The tracer-based maximal metabolic models enabled the computer simulation of the human metabolic system.

    “The tracer-based”

    From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [65]

    The Introduction (page not indicated) says the meal model uses measurements of glucose and insulin fluxes, and the Background says GIM simulates the glucose–insulin system. Our copy does not describe the model as tracer-based or maximal, or claim that it simulates the human metabolic system as a whole. (LLM, conf=0.85)

    Experimental — accuracy not yet measured
  • The Hovorka model and the UVAPadova Simulator describe only the glucose metabolism of a subject with type 1 diabetes.

    “While the Hovorka model and the UVAPadova Simulator only describe the glucose metabolism of a subject with type 1 diabetes, the Sorensen model was formulated to simulate the behaviour of both normal and diabetic individuals.”

    From A comparison among three maximal mathematical models of the glucose-insulin system (2021) · cites this paper as [25]

    The References list a Hovorka study of glucose control in subjects with type 1 diabetes, but that does not establish that the Hovorka model describes only type 1 diabetes. The paper does not identify a UVAPadova Simulator or establish the same restriction for it. Its Introduction and Methods instead say that the software presented here, GIM, simulates normal, type 2 diabetic, and type 1 diabetic subjects. (LLM, conf=0.76)

    Experimental — accuracy not yet measured
  • The formulation adopted in the UVAPadova model is marginally more complicated: if the parameter ka1 is set to zero and the parameter ka2 is set to the same value as the parameter kd, then the two formulations are equivalent.

    “The formulation adopted in the UVAPadova model is marginally more complicated: if the parameter ka1 is set to zero and the parameter ka2 is set to same value as the parameter kd, then the two formulations are equivalent.”

    From A comparison among three maximal mathematical models of the glucose-insulin system (2021) · cites this paper as [25]

    The Introduction (page not available) describes a subcutaneous-insulin formulation using kd, ka1, and ka2. It does not compare that formulation with another model or state that setting ka1 to zero and ka2 equal to kd makes the two equivalent. (LLM, conf=0.76)

    Experimental — accuracy not yet measured
  • The parameters of the Hovorka and UVA/Padova models are indicated for a diabetic individual.

    “The parameters of the Hovorka and UVA/Padova models are instead indicated for a diabetic individual, but the more compact formulation of the Hovorka model requires fewer modifications to obtain a good fit.”

    From A comparison among three maximal mathematical models of the glucose-insulin system (2021) · cites this paper as [25]

    The Introduction (pp. 323–330; page not specified in our copy) describes GIM settings for simulating type 1 and type 2 diabetic subjects, which supports the diabetic-simulation aspect of the claim. It does not identify GIM as the UVA/Padova model or describe parameters of the Hovorka model; Hovorka appears only in the references. Nor does it compare how many modifications the models require. (LLM, conf=0.78)

    Experimental — accuracy not yet measured
  • Model 1 follows the structure of the previously developed subcutaneous insulin delivery model.

    “Model 1, the simplest linear model representation with a pool compartment (compartment 2), follows the structure of the previously developed SC insulin delivery model.18,19”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dalla Man, C., Raimondo, D. M., Rizza, R. A., & Cobelli, C.
Affiliations
  • Department of Information Engineering, University of Padova, I-35131 Padova, Italy
  • University of Pavia (IT)
  • Mayo Clinic (US)
  • University of Padua (IT)
Corresponding author
Cobelli, Claudio
Venue
Journal of Diabetes Science and Technology
Published
2007-05
Volume
1
Issue
3
Pages
323-330
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2114131699
Cited by
253
References
21
Citations by year
2026: 5 · 2025: 7 · 2024: 6 · 2023: 9 · 2022: 7 · 2021: 10 · 2020: 14 · 2019: 15 · 2018: 23 · 2017: 17 · 2016: 13 · 2015: 15 · 2014: 24 · 2013: 24 · 2012: 19
Type
conference abstract
Language
en
Open access
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • ArTS Archivio della ricerca di Trieste (University of Trieste https://www.units.it/) (submittedVersion)
  • Padua Research Archive (University of Padova) (submittedVersion)
Funders
  • University of Virginia
  • National Institutes of Health
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
glucose-insulin model, type 1 diabetes, type 2 diabetes, glucose metabolism, insulin resistance, diabetes education

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review