Nonlinear Metabolic Effect of Insulin Across the Blood Glucose Range in Patients with Type 1 Diabetes Mellitus
Open accessAbstract
Background: For insulin therapy to successfully maintain blood glucose (BG) levels of patients with type 1 diabetes mellitus (T1DM) in normoglycemia, it is necessary to understand if the metabolic effect of insulin across the BG range is linear or not. Methods: We assess the ability of insulin to lower BG in patients with T1DM in hypoglycemia and hyperglycemia. The net metabolic effect of insulin, defined as the total effect resulting from both reduced endogenous glucose production and increased glucose uptake, was used to define the insulin effectiveness (IE), a measure that indicates the amplitude of glucose lowering that a unit of active insulin can achieve at a given BG level. The IE was assessed in hypoglycemia and hyperglycemia through two separate studies. In the first study, patients were subjected to a hyperinsulinemic euglycemic and hypoglycemic glucose clamp. In the second study, another group of patients were clamped at a hyperglycemic level. Results: The IE increased by 75% when BG dropped from 90 to 50 mg/dl at a steady rate of 1 mg/d1/min and decreased by 10% when BG was increased from 100 to 200 mg/d1. Conclusions: The net metabolic effect of insulin is nonlinear across the BG range and is amplified in hypoglycemia and dampened in hyperglycemia. Most importantly, the BG lowering per unit of insulin is accelerated when falling into hypoglycemia. The understanding of the accelerated risk for hypoglycemia with falling glucose levels will help the design of more robust hypoglycemia prevention and detection systems.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Recent studies have provided new insights into nonlinearities of insulin action in the hypoglycemic range and into glucagon kinetics as it relates to response to hypoglycemia.
“Recently new data and models have become available on hypoglycemia 5 and counterregulation. 6,7”
From The UVA/PADOVA Type 1 Diabetes Simulator: New Features (2014) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425 · see citing works
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955 · see citing works
Rossetti, L., Giaccari, A., & DeFronzo, R. A. (1990) · Diabetes Care · doi:10.2337/diacare.13.6.610 · Cited by 774 · see citing works
How to measure insulin sensitivity
Ferrannini, E., & Mari, A. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816070-00001 · Cited by 552 · see citing works
Unger, R. H., & Grundy, S. M. (1985) · Diabetologia · doi:10.1007/bf00273856 · Cited by 452 · see citing works
Sparacino, G., Zanderigo, F., Corazza, S., Maran, A., Facchinetti, A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889774 · Cited by 339 · see citing works
Insulin sensitivity and its measurement: structural commonalities among the methods.
Radziuk, J. (2000) · Journal of Clinical Endocrinology and Metabolism · doi:10.1210/jcem.85.12.7025 · Cited by 323 · see citing works
Kinetics of glucose disposal in whole body and across the forearm in man.
Yki‐Järvinen, H., Young, A. A., Lamkin, C., & Foley, J. E. (1987) · Journal of Clinical Investigation · doi:10.1172/jci113011 · Cited by 265 · see citing works
The action of insulin on the transport of glucose through the cell membrane
Park, C. R., REINWEIN, D., Henderson, M. J., Cadenas, E., & Morgan, H. E. (1959) · The American Journal of Medicine · doi:10.1016/0002-9343(59)90227-x · Cited by 259 · see citing works
Symmetrization of the Blood Glucose Measurement Scale and Its Applications
Kovatchev, B. P., Cox, D. J., Gonder-Frederick, L. A., & Clarke, W. L. (1997) · Diabetes Care · doi:10.2337/diacare.20.11.1655 · Cited by 258 · see citing works
Self-citationHyperglycemia Decreases Glucose Uptake in Type I Diabetes
Yki‐Järvinen, H., Helve, E., & Koivisto, V. A. (1987) · Diabetes · doi:10.2337/diab.36.8.892 · Cited by 198 · see citing works
Effects of Plasma Glucose Concentration on Glucose Utilization and Glucose Clearance in Normal Man
Verdonk, C. A., Rizza, R. A., & Gerich, J. E. (1981) · Diabetes · doi:10.2337/diab.30.6.535 · Cited by 144 · see citing works
Glycemic Characteristics in Continuously Monitored Patients With Type 1 and Type 2 Diabetes
Bode, B. W., Schwartz, S., Stubbs, H. A., & Block, J. E. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2361 · Cited by 137 · see citing works
Hypoglycemia Prediction and Detection Using Optimal Estimation
Palerm, C. C., Willis, J. P., Desemone, J., & Bequette, B. W. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.3 · Cited by 94 · see citing works
Palerm, C. C., & Bequette, B. W. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100505 · Cited by 89 · see citing works
Effects of aging on glucose-mediated glucose disposal and glucose transport.
Fink, R., Wallace, P., & Olefsky, J. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112533 · Cited by 75 · see citing works
Statistical Hypoglycemia Prediction
Cameron, F., Niemeyer, G., Gundy-Burlet, K. L., & Buckingham, B. A. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200412 · Cited by 60 · see citing works
Gottesman, I. S., Mandarino, L. J., Verdonk, C. A., Rizza, R., & Gerich, J. E. (1982) · Journal of Clinical Investigation · doi:10.1172/jci110731 · Cited by 56 · see citing works
(2007) · Wiley eBooks · doi:10.1002/9780470513095 · Cited by 25 · see citing works
Kovatchev, B. P., Farhy, L. S., Cox, D. J., Straume, M., Yankov, V. I., Gonder-Frederick, L. A., & Clarke, W. L. (1999) · Computational and Mathematical Methods in Medicine · doi:10.1080/10273669908833028 · Cited by 17 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 1
- Yki-Järvinen H. Glucose toxicity. Endocr Rev. 1992;13(3):415-31.
Cited by
Sorted by citations
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791 · see citing works
Self-citationLee, S., Kim, J., Park, S. W., Jin, S., & Park, S. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3002022 · Cited by 86 · see citing works
[Mathematical Modeling of the Blood Glucose Regulation System in Diabetes Mellitus Patients].
Karpel'ev, V. A., Filippov, Y., Tarasov, Y. V., Boyarsky, M. D., Mayorov, A. Y., Shestakova, M., & Dedov, I. (2015) · Vestnik Rossiiskoi akademii meditsinskikh nauk · doi:10.15690/vramn.v70.i5.1441 · Cited by 16 · see citing works
Diabetes - Damages and Treatments
Rigobelo, E. (2011) · InTech eBooks · doi:10.5772/1823 · Cited by 2 · see citing works
Diabetes Mellitus Glucose Prediction by Linear and Bayesian Ensemble Modeling
Ståhl, F. L. (2012) · Lund University Publications (Lund University) · Cited by 13 · see citing works
Trends in FDA Regulation of Software to Control Insulin Dosing
Klonoff, D. C., & AIMBE, F. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815578481 · Cited by 6 · see citing works
Hypoglycemia Prevention in Closed-Loop Artificial Pancreas for Patients with Type 1 Diabetes
Abu-Rmileh, A., & García-Gabín, W. (2011) · InTech eBooks · doi:10.5772/22647 · Cited by 3 · see citing works
Glucose Predictions Improve Glycemic Control: A Digital Twin Evaluation
Herrero, P., Andorrà, M., Breton, M. D., Peak, A., Koehler, M., Klopfenstein, Y., Leppäaho, E., Zanon, M., Ringemann, C., Lustenberger, P., et al. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261432144 · Cited by 3 · see citing works
Self-citationPredicting Nocturnal Hypoglycemia Using a Non-parametric Insulin Action Model
Ståhl, F. L., Johansson, R., & Olsson, M. L. (2015) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2015.280 · Cited by 2 · see citing works
Robust two-degree-of-freedom control: A simulation-based approach for adults population with T1D
García-Rodríguez, J. A., Guy Yaoyotzin Cortés, S., Diaz-Velazco, R. C., Gudiño-Ochoa, A., & Navarrete‐Guzmán, A. (2024) · Results in Control and Optimization · doi:10.1016/j.rico.2024.100454 · Cited by 1 · see citing works
Kernel-based Estimate of the Insulin Action of Rapid-Acting Insulin in Home-Monitored Data
Ståhl, F. L., Lindström, E., Olsson, M. L., & Johansson, R. (2015) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2015.12.214 · Cited by 1 · see citing works
High molecular weight adiponectin as an adjunct biomarker for insulin dysregulation in equids
de Laat, M. A., Fitzgerald, D. M., Li, F. I., Sillence, M. N., & McGree, J. M. (2026) · Journal of Veterinary Internal Medicine · doi:10.1093/jvimsj/aalag186
Abu-Rmileh, A. (2013) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
- Authors
- Chan, A., Heinemann, L., Anderson, S. M., Breton, M. D., & Kovatchev, B. P.
- Affiliations
- University of Virginia Health System (US)
- Profil Institute for Metabolic Research (DE)
- Corresponding author
- Chan, Alice
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-07
- Volume
- 4
- Issue
- 4
- Pages
- 873-881
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2909519
- OpenAlex
- W2131590286
- Cited by
- 13
- References
- 20
- Citations by year
- 2026: 2 · 2024: 1 · 2020: 1 · 2015: 4 · 2014: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Deutsches Krebsforschungszentrum
- National Institutes of Health (5r01dk051562-23)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK 51562, R01DK085623)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
- Keywords
- type 1 diabetes, blood glucose, hypoglycemia, hyperglycemia, endogenous glucose production, glucose uptake, hyperinsulinemic-euglycemic clamp, hypoglycemic clamp, hyperglycemic clamp, hypoglycemia prevention
- MeSH terms
- Adult, Algorithms, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glucose, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin, Male, Middle Aged, Glucose Clamp Technique, Treatment Outcome, Nonlinear Dynamics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review