The Effect of Real-Time Continuous Glucose Monitoring on Glycemic Control in Patients with Type 2 Diabetes Mellitus
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Background: Real-time continuous glucose monitoring (RT-CGM) improves hemoglobin A1c (A1C) and hypoglycemia in people with type 1 diabetes mellitus and those with type 2 diabetes mellitus (T2DM) on prandial insulin; however, it has not been tested in people with T2DM not taking prandial insulin. We evaluated the utility of RT-CGM in people with T2DM on a variety of treatment modalities except prandial insulin. Methods: We conducted a prospective, 52-week, two-arm, randomized trial comparing RT-CGM ( n = 50) versus self-monitoring of blood glucose (SMBG) ( n = 50) in people with T2DM not taking prandial insulin. Real-time continuous glucose monitoring was used for four 2-week cycles (2 weeks on/1 week off). All patients were managed by their usual provider. This article reports on changes in A1C 0–12 weeks. Results: Mean (±standard deviation) decline in A1C at 12 weeks was 1.0% (±1.1%) in the RT-CGM group and 0.5% (±0.8%) in the SMBG group ( p = .006). There were no group differences in the net change in number or dosage of hypoglycemic medications. Those who used the RT-CGM for ±48 days (per protocol) reduced their A1C by 1.2% (±1.1%) versus 0.6% (±1.1%) in those who used it <48 days ( p = .003). Multiple regression analyses statistically adjusting for baseline A1C, an indicator for usage, and known confounders confirmed the observed differences between treatment groups were robust ( p = .009). There was no improvement in weight or blood pressure. Conclusions: Real-time continuous glucose monitoring significantly improves A1C compared with SMBG in patients with T2DM not taking prandial insulin. This technology might benefit a wider population of people with diabetes than previously thought.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, CGM use has been reported to reduce fear of hypoglycemia and increase confidence in avoiding/treating hypoglycemia.156,174,175”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [175]
In the citing paper
“Fonda and colleagues 59 reported on the cost‐effectiveness of the periodic rtCGM intervention previously reported by Ehrhardt et al. 33 Based on 2011 pricing, they found that intermittent rtCGM was a cost‐effective option, with incremental cost‐effectiveness ratios of $9319 and $13 030 per (life year) LY and (quality‐adjusted life year) QALY gained, substantially lower than typical ‘willingness‐to”
In the citing paper
“Randomized controlled trials of the use of rt-CGM, compared with standard blood glucose monitoring, in adults with type 2 diabetes have generally shown reductions in HbA 1c with no significant change in time in hypoglycemia (169-172).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [170]
In the citing paper
“RCT data on rtCGM use in individuals with type 2 diabetes on MDI (59), mixed therapies (10, 60), and basal insulin (61,62) have consistently shown reductions in A1C levels and increases in TIR (70-180 mg/dL [3.9-10 mmol/L]) but not a reduction in rates of hypoglycemia (63).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [60]
In the citing paper
“In these RCTs, people with type 2 diabetes not on intensive insulin therapy used CGM intermittently compared with those randomized to BGM.Both early (60) and late improvements in A1C levels were found (60,73).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [60]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Fitzmaurice, G. M., Laird, N. M., & Ware, J. H. (2011) · Wiley Series in Probability and Statistics · doi:10.1002/9781119513469 · Cited by 4,639
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Basevi, V., Di Mario, S., Morciano, C., Nonino, F., & Magrini, N. (2011) · Diabetes Care · doi:10.2337/dc11-0174 · Cited by 3,055
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
(2004) · Choice Reviews Online · doi:10.5860/choice.42-2265 · Cited by 1,384
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Research works printed but not linked: 1
- Towfgh A, 2008, Am J Manag Care., 14, 468
Cited by
Items 101–199 of 199
Anticoagulation protocol and early prosthetic valve thrombosis.
Talwar, S., Kapoor, C. K., Devagourou, V., & Kumar, A. S. (2004) · PubMed · Cited by 24
Zivojinovic, A. S. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.105605 · Cited by 22
Zhou, J., Lv, X., Mu, Y., Wang, X., Li, J., Zhang, X., Wu, J., Bao, Y., & Jia, W. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0014 · Cited by 20
“Ehrhardt et al.7 found that RT-CGM significantly improved hemoglobin A1c compared with the self-monitoring of blood glucose in patients with type 2 diabetes mellitus.”
BackgroundRizos, E. C., Markozannes, G., Charitakis, N., Filis, P., Stoimeni, A. E., Nørgaard, K., Ntzani, E. E., & Tsilidis, K. K. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0599 · Cited by 21
Fritschi, C., Kim, M. J., Srimoragot, M., Jun, J., Sanchez, L. E., & Sharp, L. K. (2022) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106221076042 · Cited by 19
Lever, C. S., Williman, J. A., Boucsein, A., Watson, A. S., Sampson, R. S., Sergel‐Stringer, O. T., Keesing, C., Chepulis, L. M., Wheeler, B. J., de Bock, M. I., et al. (2024) · Diabetic Medicine · doi:10.1111/dme.15348 · Cited by 20
“7,9,10,11 In New Zealand, T2D is largely managed in primary care, where cost/availability of ap-pointments and the variability in knowledge and skills of non-specialist practitioners influence patient access to appropriate care.”
Continuous glucose monitoring: a systematic review of sensor systems and prospects
Ray, P. P. (2018) · Sensor Review · doi:10.1108/sr-12-2017-0268 · Cited by 20
Sherrill, C. H., Lee, S., & Bradley, C. L. (2021) · Currents in Pharmacy Teaching and Learning · doi:10.1016/j.cptl.2021.11.021 · Cited by 20
A Conditional Generative Adversarial Network for Synthesis of Continuous Glucose Monitoring Signals
Cichosz, S. L., & Xylander, A. A. P. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211014255 · Cited by 21
Emerging technologies for the management of type 2 diabetes mellitus
Shah, N. A., & Levy, C. J. (2021) · Journal of Diabetes · doi:10.1111/1753-0407.13188 · Cited by 18
“04).(50) Beck and colleagues in the “Multiple Daily Injections and Continuous Glucose Monitoring in Diabetes (DIAMOND)” T2DM study reported a 0.”
BackgroundEngler, S., Fields, S. A., Leach, W., & Loon, M. V. (2022) · Journal of Technology in Behavioral Science · doi:10.1007/s41347-022-00247-5 · Cited by 15
“, 2016); RT-CGM usability (Ehrhardt et al., 2011), perceived frequency of unacceptable blood glucose levels (Tang et al.”
BackgroundInfluentialWysocki, M., Szopa, M., Stefura, T., Dudek, A., Torbicz, G., Gajewska, N., Pędziwiatr, M., Małczak, P., Pisarska, M., Budzynski, A. Z., et al. (2019) · Obesity Surgery · doi:10.1007/s11695-018-03684-5 · Cited by 16
Continuous glucose monitoring to assess glucose variability in type 3c diabetes
Lee, V. T. Y., Poynten, A. M., & Depczynski, B. (2022) · Diabetic Medicine · doi:10.1111/dme.14882 · Cited by 18
Utilizing point-of-care A1c to impact outcomes – can we make it happen in primary care?
Rhyu, J., Lambrechts, S. I., Han, M. A., & Freeby, M. (2021) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000700 · Cited by 11
“improve glycemic control by changing both physician and patient behaviors [20,21].”
BackgroundPeters, A. L., Cohen, N., Calhoun, P. M., Ruedy, K. J., Beck, R. W., Martens, T. W., Bao, S., Njeru, N. M., Beck, S. E., & Price, D. A. (2020) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14238 · Cited by 9
“78) U/kg/day, which was equivalent to 45 ± 28 (7-210) U/day.”
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Ga, F., & Heinemann, L. (2018) · Yearbook of pediatric endocrinology · doi:10.1530/ey.15.10.9 · Cited by 10
Continuous Glucose Monitoring for the Internist
Lee, G. S., & Lupsa, B. C. (2021) · Medical Clinics of North America · doi:10.1016/j.mcna.2021.06.004 · Cited by 13
Lind, N., Hansen, D. L., Rasmussen, S. S., & Nørgaard, K. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-040648 · Cited by 10
Cowart, K. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819890865 · Cited by 9
Eer, A., Ho, R. C. Y., Hearn, T., Hachem, M., Freund, M., Burchill, L. J., Atkinson‐Briggs, S., Singh, S., Eades, S., O’Brien, R. C., et al. (2023) · BMC Health Services Research · doi:10.1186/s12913-023-10121-6 · Cited by 9
“Some studies have shown that the data from FGM can lead to improvements in glycaemic management in people with T2DM independent of changes in diabetes medications [11, 21, 22].”
BackgroundHallström, S., Hirsch, I. B., Ekelund, M., Sofizadeh, S., Albrektsson, H., Dahlqvist, S., Svensson, J., & Lind, M. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0577 · Cited by 9
Chan, T. I., Yip, Y. W. Y., Man, T. T. C., Pang, C. P., & Brelen, M. E. (2022) · Translational Vision Science & Technology · doi:10.1167/tvst.11.11.3 · Cited by 10
Ko, J., Moon, S., Ajjan, R. A., Lee, M. Y., Lee, H., Choi, B., Park, J., Lee, S., Kang, J., & Park, C. (2025) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.16304 · Cited by 7
Hayek, A. A., Klonoff, D. C., Zahrani, W. M. A., Saeed, A. H. A., & Dawish, M. A. A. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112458 · Cited by 8
Wu, C. C., Wu, K. C., José, A. S., & Novin, N. (2022) · JMIR Diabetes · doi:10.2196/30626 · Cited by 7
“patients with type 1 and type 2 diabetes [16-20].”
The Changing Landscape of Glycemic Targets: Focus on Continuous Glucose Monitoring
Kushner, P. R., & Kruger, D. F. (2020) · Clinical Diabetes · doi:10.2337/cd19-0093 · Cited by 8
Kim, H., Yang, Y., Ahn, J., & Kang, J. H. (2025) · BMC Geriatrics · doi:10.1186/s12877-025-06575-4 · Cited by 7
“As evidence supporting the clinical benefits of CGM for insulin-treated individuals with type 2 diabetes continues to grow [9, 10], the 2023 Asia-Pacific Consensus Statement on CGM recommends the proactive use of CGM in frail older adults with type 2 diabetes, regardless of whether they are on oral…”
Brännvall, R., Forsgren, H., Linge, H. M., Santini, M., Salehi, A., & Rahimian, F. (2022) · Swedish Artificial Intelligence Society Workshop (SAIS) · doi:10.1109/sais55783.2022.9833062 · Cited by 6
Continuous glucose monitoring: the clinical picture. How to interpret and use the data
Hammond, P. J. (2012) · Practical Diabetes · doi:10.1002/pdi.1723 · Cited by 6
A Position Statement of the Utilization and Support Status of Continuous Glucose Monitoring in Korea
Kim, W. J., Kim, J. H., Yoo, H. J., Son, J. W., Khang, A. R., Kwon, S. K., Kim, J. H., Kim, T. H., Ryu, O. H., Park, K. H., et al. (2021) · Journal of Korean Diabetes · doi:10.4093/jkd.2021.22.4.225 · Cited by 7
“경구혈당강하제 병용 또는 경구혈당강하제를 단독 사용하는 2형당뇨병 성인은 개인형 CGM의 간헐적 사용으로 당화혈색 소가 개선되었다[39-42].”
Lever, C. S., Williman, J. A., Boucsein, A., Watson, A. S., Sampson, R. S., Sergel‐Stringer, O. T., Keesing, C., Chepulis, L. M., Wheeler, B. J., de Bock, M. I., et al. (2023) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-023-01244-y · Cited by 6
Ehrhardt, N. M., Cedeno, B., Montour, L., Sinclair, K., Ferguson, G., Berberian, P., Comstock, B. A., & Wright, L. A.-C. (2023) · BMJ Open · doi:10.1136/bmjopen-2023-082005 · Cited by 9
“23 We previously showed that cyclical RT-CGM use over 3 months significantly improved haemoglobin A1c (A1c) in subjects with T2D not using prandial insulin 24 and that this improvement was sustained beyond the period of RT-CGM use.”
BackgroundSelf-citationClinical and Financial Outcomes of a Pilot Pharmacist-Led Continuous Glucose Monitoring Clinic
Ballard, L., York, A. L., Skelley, J. W., & Sims, M. (2024) · INNOVATIONS in pharmacy · doi:10.24926/iip.v15i1.6081 · Cited by 8
Aihara, M., Yano, K., Irie, T., Nishi, M., Yachiku, K., Minoura, I., Sekimizu, K., Sakurai, Y., Kadowaki, T., Yamauchi, T., et al. (2024) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111903 · Cited by 6
Ndungu, M., Babalola, R. O., Brand, M., & Patel, R. S. (2025) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.2078 · Cited by 5
Clinical Impact of Continuous Glucose Monitoring in Noninsulin Treated Type 2 Diabetes: A Review
Aleppo, G., Carlson, A. L., McGill, J. B., Alshannaq, H. A., Galindo, R. J., Kruger, D. F., Levy, C. J., Matuoka, J. Y., Ilham, S., Umpierrez, G. E., et al. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251414980 · Cited by 6
“Overall, a trend toward improvement in diabetes empowerment, 29,51 diabetes-related stress, 35,53,54,56 and diabetes skills, con fi dence, and preparedness 30 was observed for CGM patients.”
Lind, N., Christensen, M. B., Hansen, D. L., Willaing, I., & Nørgaard, K. (2024) · Diabetic Medicine · doi:10.1111/dme.15321 · Cited by 6
Enhancing Type 2 Diabetes Care With CGM Integration: Insights From an Italian Expert Group
Irace, C., Avogaro, A., Bertuzzi, F., Buzzetti, R., Candido, R., Prato, S. D., Bartolo, P. D., Fiorina, P., Giorda, C. B., & Giorgino, F. (2025) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.70059 · Cited by 7
“…52‐week, two‐arm, randomized trial comparing rtCGM ( n = 50) used for four 2‐week cycles (2 weeks on/1 week off) versus SMBG ( n = 50) in people with T2D not taking prandial insulin, demonstrated a significant improvement in HbA1c at 12 weeks ( − 1.0% � 1.1% vs. − 0.5% � 0.8%, p = 0.006) [48].”
InfluentialNeue Therapieoptionen mit kontinuierlich gemessenen Glukosedaten – Empfehlungen für die Praxis
Seufert, J., Deiss, D., Gölz, S., Haak, T., Klausmann, G., Kroeger, J., Lobmann, R., Pfeiffer, A. F. H., Schnell, O., Seibold, A., et al. (2019) · Diabetologie und Stoffwechsel · doi:10.1055/a-0978-4537 · Cited by 4
“[33] Ehrhardt NM, Chellappa M, Walker MS et al.”
BackgroundArtificial intelligence-based decision support systems for diabetes
Contreras, I., Bertachi, A. H., Biagi, L., Oviedo, S., Ramkissoon, C. M., & Vehí, J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817133-2.00014-8 · Cited by 4
Continuous Glucose Monitoring: An Opportunity for Population-Based Diabetes Management
Skoufalos, A., Thomas, R., Patel, R. R., Mei, C., & Clarke, J. L. (2022) · Population Health Management · doi:10.1089/pop.2022.0196 · Cited by 5
“44 Ehrhardt et al., 45 and Cox et al. 46 rtCGM with coaching provides opportunities to positively impact other HEDIS measures (eg, Controlling High Blood Pressure , Transitions of Care between Inpatient and Out-patient Settings , reminders to obtain necessary screening such as Diabetes Care Eye…”
Continuous Glucose Monitoring in 2011
Battelino, T., & Bode, B. W. (2012) · Wiley eBooks · doi:10.1002/9781118321508.ch2 · Cited by 4
Addressing the Diabetes Tsunami Requires Expanded Access to Diabetes Technologies
Kruger, D. F., Parkin, C. G., Hirsch, I. B., Aleppo, G., McGill, J. B., Galindo, R. J., Levy, C. J., Umpierrez, G. E., Grunberger, G., & Bergenstal, R. M. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251332956 · Cited by 4
Continuous Glucose Monitoring in Non-Insulin Type 2 Diabetes
Kesavadev, J., Saboo, B., Makkar, B. M., Agarwal, S., Chawla, M. S., Chandran, V., Shankar, A., & Basanth, A. (2023) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_26_23 · Cited by 3
Nørlev, J. T. D., Kronborg, T., Jensen, M. H., Rana, P., Vestergaard, P., & Hangaard, S. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112191 · Cited by 4
Pedone, E., Laurenzi, A., Allora, A., Bolla, A. M., & Caretto, A. (2020) · Exploration of Medicine · doi:10.37349/emed.2020.00021 · Cited by 3
“Despite limited evidences and trials about the use of CGM in subjects with T2D, Italian recommendations agree with applying intermittent or CGM in T2D adults at risk of hypoglycemia, as a way to optimize glycemic variability [24, 27, 70].”
BackgroundHeitkemper, E., Wilcox, G. B., Zuniga, J. A., Kim, M. T., & Cuevas, H. E. (2023) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106231158828 · Cited by 4
“(3) communication channels, (4) time, and (5) a social system.”
BackgroundEmpowering People with Diabetes: Role of Continuous Glucose Monitor Systems
Srivastava, S. B. (2023) · American Journal of Lifestyle Medicine · doi:10.1177/15598276231158044 · Cited by 5
“Lifestyle Changes Improve Health Outcomes in Diabetes Patients Sufficiently intensive lifestyle interventions have shown to induce diabetes remission and it is recommended that intensive lifestyle changes be the primary modality for type 2 diabetes care with remission as the goal.7 The 2013 Obesity Guidelines describe…”
BackgroundJinnouchi, H., Yoshida, A., Taniguchi, M., Yamauchi, E., Kurosawa, D., Yachiku, K., Minoura, I., Kadowaki, T., Yamauchi, T., Aihara, M., et al. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01599-2 · Cited by 3
“Structured self-monitoring of blood glucose (SMBG) and continuous glucose monitoring (CGM) are known to be effective for glycemic management [8–10].”
BackgroundAdvancing Diabetes Quality Measurement in the Era of Continuous Glucose Monitoring
Khan, M., Wahid, N., Musser, T., Bergenstal, R. M., Ebekozien, O. A., Snow, K. J., Thomas, K., & Aprigliano, C. M. (2023) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106231163518 · Cited by 3
In Pursuit of an Ideal – A Perspective on Non-Invasive Continuous Glucose Monitoring
English, L. B., & Director of Scientific and Technological Affairs, C. M. (2010) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2012.08.01.18 · Cited by 3
Krishnamoorthy, U., Karthika, V., Mathumitha, M. K., Aakash, J. R., & Gokul, M. (2023) · International Conference on Electrical Energy Systems (ICEES) · doi:10.1109/icees57979.2023.10110151 · Cited by 3
“Type I and Type II diabetes are the two most common forms depending on the whether the body cannot synthesize insulin or it cannot use the insulin produced by the system respectively [3,4,5].”
BackgroundAllaire, J. C., Dennis, C., Wright, E. E., Edelman, S. V., & Masturzo, A. (2025) · Clinical Diabetes · doi:10.2337/cd24-0108 · Cited by 3
Scarlett, L. D., Solorzano, W. M., Khoshbin, K., Villanueva, G. P., Mangual, K. P. S., Tavares, M., Santana, C., Escobar, B., Borrell, J. A., Brumley, B., et al. (2025) · Journal of Diabetes Research · doi:10.1155/jdr/5724236 · Cited by 3
Евгеньевна, Р. Г. (2021) · Meditsinskiy sovet = Medical Council · doi:10.21518/2079-701x-2021-12-286-292 · Cited by 3
L’internista ospedaliero nella gestione del paziente diabetico complesso
Magnani, G. E. L., Beltramello, G., Brancato, D., Fontanella, A., & Nardi, R. (2018) · Italian Journal of Medicine · doi:10.4081/itjm.q.2018.2 · Cited by 2
Glucose Management Using Continuous Glucose Monitors
Kang, Y. (2019) · Journal of Korean Diabetes · doi:10.4093/jkd.2019.20.1.42 · Cited by 2
Insulin Pumps and Artificial Pancreas
Taleb, N., Gingras, V., & RABASA-LHORET, R. P. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.65407-7 · Cited by 3
2023 Clinical Practice Guidelines for Diabetes: Continuous Glucose Monitoring and Insulin Pumps
Jin, S. (2023) · Journal of Korean Diabetes · doi:10.4093/jkd.2023.24.3.141 · Cited by 2
“실시간으로 인슐린용량을 조정하는 인슐린치료와 달리, 식 전초단기작용인슐린을 사용하지 않고 기저인슐린만 사용하 는 2형당뇨병 성인, 혹은 비인슐린치료만 사용하는 2형당뇨 병 성인에서는 보다 간소한 수준의 교육과 함께 연속혈당측 정을 간헐적으로 사용하는 경우도 유의한 당화혈색소 감소 효과를 보여주었다[20,21].”
Cebada, A. B., Silva, J. B. Q., Escobar-Morreale, H. F., & Chávez, L. N. (2024) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/j.med.2024.10.010 · Cited by 5
Berthoumieux, A., Naqvi, J. B., Zion, S. R., Napoleone, J. M., McGuill, A., Cerrada, C. J., Lee, H. J., Dunn, T. C., Kerr, D. E., Jasik, C. B., et al. (2026) · Journal of Medical Internet Research · doi:10.2196/78321 · Cited by 2
“Previous research revealed that using CGM for 8 weeks helped people with diabetes significantly reduce their HbA 1c by an average 1-point reduction, which is consistent with our present study and demonstrates the importance of self-monitoring for diabetes management [38].”
Olu-Jordan, I., Singh, P. K., Zheng, J. R., Yeung, R. O., Manca, D. P., Perry, T., Rahim, G., Hagen, E., & Lau, D. (2025) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2025.10.174 · Cited by 3
Liu, A., Phoenix, A., Huggins, C. E., & Leung, V. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251387149 · Cited by 1
Almehthel, M. S., Al-Saeed, A., Alsabaan, F., Almalki, F., ZARIF, H. A., Al-Zubaidi, L., Al‐Sofiani, M. E., Abdulaal, O., Argan, R. A., Sifri, S. A., et al. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1738398 · Cited by 2
Kesavadev, J., Toh, S. A., Kong, A. P.-S., McGill, M. J., Ashik, A., Lee, M. H., Chun Kwan, O., & Twigg, S. M. (2026) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_40_25 · Cited by 1
Crowe, D. J. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500517 · Cited by 1
Continuous glucose monitoring in 2011
Battelino, T., & Bode, B. W. (2012) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2011.02848.x · Cited by 1
Continuous Glucose Monitoring in a Patient With Insulin-Treated Type 2 Diabetes
Joyce, M., & Pick, A. J. (2013) · Clinical Diabetes · doi:10.2337/diaclin.31.2.79 · Cited by 1
Paul, D. P., Ashworth, S., Salyers, L., Saldanha, S., & Coustasse, A. (2016) · Cited by 1
Cheng, K. K., Cruz, M. F. V., Tylee, T. S., & Kelly, M. S. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251320122 · Cited by 1
“9,21 While this study is not a randomized controlled trial and we cannot solely attribute the reduction in HbA 1c to the implementation of the CGM, the lack of demonstrated effect of confounding factors that could influence glycemic control provides additional support for the impact of CGM…”
Type 2 Diabetes Melittus–A Pathology on the Rise How do we Monitor it?
Lucia, F. E. S. M. (2013) · Pharmaceutica Analytica Acta · doi:10.4172/2153-2435.1000e160
“Volume 4 • Issue 10 • 1000e160 Pharmaceut Anal Acta ISSN: 2153-2435 PAA, an open access journal maintaining optimal glycemic profile over a long period of time [7,8].”
BackgroundAvancées technologiques et traitement du diabète
Roy‐Fleming, A., & Taleb, N. (2018) · Nutrition, science en évolution · doi:10.7202/1048943ar · Cited by 1
“En présence d’insulinothérapie intensive, elle est associée à une baisse de l’HbA1C tant dans le DbT1 que le DbT2 [12, 13].”
InfluentialRole of Continuous Glucose Monitoring Technology for Type 2 Diabetes Management
Taylor, P. (2019) · Adelaide Research & Scholarship (AR&S) (University of Adelaide)
Tildesley, H. D., Wright, A. M., Chan, J. H. M., Mazanderani, A. B., Ross, S. A., Tildesley, H. G., Lee, A. M., Tang, T. S., & White, A. S. (2016) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2016.04.003
RetractedClinical and economic benefits of continuous blood glucose monitoring devices
Rahman, R. S., Salamah, H. E., Alshair, F. M., Alsawadi, A. A., Alghamdi, O. M., Alalasi, A. B., Mufarrihi, A. M., Alalawi, A. O., Alzahrani, O. M., Alanazi, H. O., et al. (2022) · International Journal of Community Medicine and Public Health · doi:10.18203/2394-6040.ijcmph20220053
“A previous investigation that included both T1DM and T2DM reported that using flash CGM in these patients was significantly associated with more reduction in HbA1c levels than SMBG.”
ResultInfluentialKerekovska, V., Boyadzhieva, M., Zlatarova, Z. I., & Hristozov, K. (2022) · Scripta Scientifica Medica · doi:10.14748/ssm.v0i0.8120
Choe, H. J., Rhee, E., Won, J. C., Park, K. S., Lee, W., & Cho, Y. M. (2022) · doi:10.2337/figshare.20382915.v1
Choe, H. J., Rhee, E., Won, J. C., Park, K. S., Lee, W., & Cho, Y. M. (2022) · doi:10.2337/figshare.20382915
Application of Continuous Glucose Monitoring Systems in Patients With Type 2 Diabetes Mellitus
(2022) · European Journal of Medicine · doi:10.13187/ejm.2022.1.12 · Cited by 1
Il monitoraggio in continuo della glicemia: stato dell’arte
Irace, C., & Molfetta, S. D. (2022) · il Diabete · doi:10.30682/ildia2204g · Cited by 1
Saxena, R. K., Singh, A. B., & .Singh, N. P. (2023) · International Journal of Life Science and Pharma Research · doi:10.22376/ijlpr.2023.13.4.sp6.l87-l99
What Do You Need to Know About Continuous Glucose Monitoring?
Cedeno, A., & Carmichael, K. A. (2021) · Consultant · doi:10.25270/con.2021.01.00006
Alvina, A., & Pusparini, P. (2023) · Rwanda medical journal · doi:10.4314/rmj.v80i3.3
Seidu, S., Kunutsor, S. K., Ajjan, R., & Choudhary, P. (2023) · doi:10.2337/figshare.24291334.v1
Comité de Innovación. Uso de los sistemas de infusión continua de insulina en personas con DM1
Carnero, R., Saleme, A., Lequi, L., Daín, A., Campos, F. S., Sosa, L., Flores, A., & Kabakian, L. (2024) · Revista de la Sociedad Argentina de Diabetes · doi:10.47196/diab.v58i1sup.763 · Cited by 1
Chaubey, A., Chaubey, D., Dwivedi, A., Dwivedi, S., & Mishra, T. (2024) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_1950_23
“[6,7] The follow‑up was done for 3 months, and the parameters were recorded and compared with the baseline parameters.”
MethodChapter 8: Self-Management Practices: Problem Solving
Hinnen, D. A., & Guthrie, R. A. (2017) · American Diabetes Association eBooks · doi:10.2337/9781580405690.ch08
Mahfuza, U., Meyerowitz‐Katz, G., Rasheed, R. A., Dick, H., MABERLY, G. F., & Jayaballa, R. (2025) · JMIR Diabetes · doi:10.2196/64832
“Ehrhard NM [12] in a 52-week randomized controlled trial (RCT) showed HbA 1c reduced by 1% at 12 weeks with CGM compared with 0.5% with self-monitoring of blood glucose (SMBG).”
InfluentialEer, A., Hachem, M., Hearn, T., Koye, D. N., Atkinson‐Briggs, S., Jones, J. L., Eades, S., Braat, S., Twigg, S. M., Sinha, A. K., et al. (2025) · Pilot and Feasibility Studies · doi:10.1186/s40814-025-01607-7
“There are increasing numbers of RCTs demonstrating that FGM/ CGM use leads to improvements in diabetes management in type 2 diabetes without reducing HbA1c [15, 16, 20, 45–51].”
Koo, D., Bang, Y., Kim, D., Im, I., Kim, P., & Park, D. (2025) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-025-01948-6 · Cited by 1
“However, some earlier studies have indicated the limited effectiveness of CGM-based interventions on BMI reduction alone [19, 20].”
Eer, A., Ho, R. C. Y., Hearn, T., Hachem, M., Freund, M., Burchill, L. J., Atkinson‐Briggs, S., Singh, S., Eades, S., O’Brien, R. C., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26651241
Gilbert, J., Reichert, S. M., Cadieux, T., & Senior, P. A. (2026) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2026.04.007
Solorzano, W. M., Scarlett, L. D., Villanueva, G. P., Mangual, K. P. S., Santana, C., Escobar, B., Rubio, A., JACKSON, N. J., Tavares, M., Borrell, J. A., et al. (2026) · Journal of Primary Care & Community Health · doi:10.1177/21501319261433345
Park-Chong, H., Benrimon, M., & Smaldone, A. M. (2026) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106261451194
“Likewise, Ehrhardt et al 46 reported early results (3 month) of the 12-month CGM intervention study reported by Vigersky et al. 45 The trials were conducted in the United States (n = 2) and Australia (n = 2) between 2011 46 and 2021, 43 with participant size ranging from 92 35 to 299.”
Gadd, S., Willis, C., Rashid, I., Park, K. Y., Holland, K., Beal, A., Asche, C. V., Ghule, P., & Brixner, D. I. (2026) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2026.32.10.1215
Freckmann, G., König, I. R., Grube, H. C. B., Vens, M., Witt, O., Kappelmeier, V., Pethahn, K. L., Sina, C., Moser, O., & Schröder, T. (2026) · Diabetologia · doi:10.1007/s00125-026-06880-6
Hayek, A. A., Zahrani, W. M. A., Alotaibi, H. F., Jammal, M. E., & Dawish, M. A. A. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261489265
Metadata
- Authors
- Ehrhardt, N. M., Chellappa, M., Walker, M. S., Fonda, S. J., & Vigersky, R. A.
- Affiliations
- Walter Reed National Military Medical Center (US)
- Corresponding author
- Vigersky, Robert A.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2011-05
- Volume
- 5
- Issue
- 3
- Pages
- 668-675
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC3192632
- OpenAlex
- W2071796315
- Semantic Scholar
- ee10abe8dc890b07dc22a377ef7bb8da317eadb2
- Cited by
- 199
- References
- 30
- Citations by year
- 2026: 10 · 2025: 20 · 2024: 18 · 2023: 26 · 2022: 22 · 2021: 21 · 2020: 14 · 2019: 18 · 2018: 12 · 2017: 9 · 2016: 10 · 2015: 2 · 2013: 5 · 2012: 6
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- real-time continuous glucose monitoring, type 2 diabetes, glycemic control, HbA1c, self-monitoring of blood glucose, non-insulin-treated diabetes, hypoglycemia
- MeSH terms
- Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Insulin, Male, Middle Aged, Prospective Studies, Regression Analysis, Blood Glucose Self-Monitoring, Treatment Outcome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.