The Effect of Real-Time Continuous Glucose Monitoring on Glycemic Control in Patients with Type 2 Diabetes Mellitus
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Background: Real-time continuous glucose monitoring (RT-CGM) improves hemoglobin A1c (A1C) and hypoglycemia in people with type 1 diabetes mellitus and those with type 2 diabetes mellitus (T2DM) on prandial insulin; however, it has not been tested in people with T2DM not taking prandial insulin. We evaluated the utility of RT-CGM in people with T2DM on a variety of treatment modalities except prandial insulin. Methods: We conducted a prospective, 52-week, two-arm, randomized trial comparing RT-CGM ( n = 50) versus self-monitoring of blood glucose (SMBG) ( n = 50) in people with T2DM not taking prandial insulin. Real-time continuous glucose monitoring was used for four 2-week cycles (2 weeks on/1 week off). All patients were managed by their usual provider. This article reports on changes in A1C 0–12 weeks. Results: Mean (±standard deviation) decline in A1C at 12 weeks was 1.0% (±1.1%) in the RT-CGM group and 0.5% (±0.8%) in the SMBG group ( p = .006). There were no group differences in the net change in number or dosage of hypoglycemic medications. Those who used the RT-CGM for ±48 days (per protocol) reduced their A1C by 1.2% (±1.1%) versus 0.6% (±1.1%) in those who used it <48 days ( p = .003). Multiple regression analyses statistically adjusting for baseline A1C, an indicator for usage, and known confounders confirmed the observed differences between treatment groups were robust ( p = .009). There was no improvement in weight or blood pressure. Conclusions: Real-time continuous glucose monitoring significantly improves A1C compared with SMBG in patients with T2DM not taking prandial insulin. This technology might benefit a wider population of people with diabetes than previously thought.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, CGM use has been reported to reduce fear of hypoglycemia and increase confidence in avoiding/treating hypoglycemia.156,174,175”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [175]
In the citing paper
“Fonda and colleagues 59 reported on the cost‐effectiveness of the periodic rtCGM intervention previously reported by Ehrhardt et al. 33 Based on 2011 pricing, they found that intermittent rtCGM was a cost‐effective option, with incremental cost‐effectiveness ratios of $9319 and $13 030 per (life year) LY and (quality‐adjusted life year) QALY gained, substantially lower than typical ‘willingness‐to”
In the citing paper
“Randomized controlled trials of the use of rt-CGM, compared with standard blood glucose monitoring, in adults with type 2 diabetes have generally shown reductions in HbA 1c with no significant change in time in hypoglycemia (169-172).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [170]
In the citing paper
“RCT data on rtCGM use in individuals with type 2 diabetes on MDI (59), mixed therapies (10, 60), and basal insulin (61,62) have consistently shown reductions in A1C levels and increases in TIR (70-180 mg/dL [3.9-10 mmol/L]) but not a reduction in rates of hypoglycemia (63).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [60]
In the citing paper
“In these RCTs, people with type 2 diabetes not on intensive insulin therapy used CGM intermittently compared with those randomized to BGM.Both early (60) and late improvements in A1C levels were found (60,73).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [60]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Fitzmaurice, G. M., Laird, N. M., & Ware, J. H. (2011) · Wiley Series in Probability and Statistics · doi:10.1002/9781119513469 · Cited by 4,639
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Basevi, V., Di Mario, S., Morciano, C., Nonino, F., & Magrini, N. (2011) · Diabetes Care · doi:10.2337/dc11-0174 · Cited by 3,055
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
(2004) · Choice Reviews Online · doi:10.5860/choice.42-2265 · Cited by 1,384
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Research works printed but not linked: 1
- Towfgh A, 2008, Am J Manag Care., 14, 468
Cited by
6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
6. Glycemic Targets: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s006 · Cited by 744
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
6. Glycemic Targets: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
“RCT data on rtCGM use in individuals with type 2 diabetes on MDI (58), mixed therapies (59,60), and basal insulin (61,62) have consistently shown reductions in A1C but not a reduction in rates of hypoglycemia.”
BackgroundMethodSacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
Vigersky, R. A., Fonda, S. J., Chellappa, M., Walker, M. S., & Ehrhardt, N. M. (2012) · Diabetes Care · doi:10.2337/dc11-1438 · Cited by 301
Self-citation7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Current and Emerging Technology for Continuous Glucose Monitoring
Chen, C., Zhao, X.-L., Li, Z.-H., Zhu, Z.-G., Qian, S.-H., & Flewitt, A. (2017) · Sensors · doi:10.3390/s17010182 · Cited by 291
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Peters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250
“Evidence This recommendation is based on data from one wellperformed large-scale RCT performed by Vigersky and colleagues (101, 102) and one other smaller study (103) showing similar outcomes.”
Result7. Diabetes Technology: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s007 · Cited by 250
“The findings in studies withMDI alone (50) and in two studies in people using oral agents with or without insulin (48,49) showed significant reductions in A1C levels.”
BackgroundMethodRuedy, K. J., Parkin, C. G., Riddlesworth, T. D., & Graham, C. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817704445 · Cited by 225
“Hypoglycemia awareness Reduced awareness 11 (17) 7 (13) Uncertain 10 (16) 5 (9) Aware 42 (67) 41 (77)”
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
“Real-time CGM Use in Type 2 Diabetes Studies inpeoplewith type2diabetes are heterogeneous in design: in two, participants were using basal insulin with oral agents or oral agents alone (67,68); in one, individuals were on MDI alone (69).”
BackgroundMethodResultInfluentialContinuous glucose monitoring: A review of the evidence in type 1 and 2 diabetes mellitus
Lin, R., Brown, F., James, S., Jones, J., & Ekinci, E. (2021) · Diabetic Medicine · doi:10.1111/dme.14528 · Cited by 197
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-017-0255-6 · Cited by 188
“The value of continuous monitoring data for self-care modification rather than therapy adjustments has been noted previously for individuals with type 2 diabetes treated with oral therapies [18] and basal insulin [19].”
Poolsup, N., Suksomboon, N., & Kyaw, A. M. (2013) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-5-39 · Cited by 179
“Among four studies included, two studies used retrospective CGM [32,33] whereas other two studies used real-time CGM [31,34].”
BackgroundMethodResultInfluential7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
“diabetes on oral agents with or without insulin did not show reductions in rates of hypoglycemia (93,95).”
BackgroundClinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes
Carlson, A. L., Mullen, D. M., & Bergenstal, R. M. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0024 · Cited by 177
“The 12-week intervention was followed by a 40week follow-up.(7) They showed a decrease in the RT-CGM group’s mean unadjusted HbA1c of 1.”
7. Diabetes Technology: Standards of Care in Diabetes—2026
Bajaj, M. S., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Early, K. B., ChallaSivaKanaka, S., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc26-s007 · Cited by 293
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
Improving the clinical value and utility of CGM systems: issues and recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetologia · doi:10.1007/s00125-017-4463-4 · Cited by 149
Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
Use of Microneedle Array Devices for Continuous Glucose Monitoring: A Review
El-Laboudi, A., Oliver, N. S., Cass, A., & Johnston, D. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0188 · Cited by 131
2023 Clinical Practice Guidelines for Diabetes Mellitus of the Korean Diabetes Association
Choi, J. H., Lee, K. A., Moon, J. H., Chon, S., Kim, D. J., Kim, H. J., Kim, N. H., Seo, J. A., Kim, M. K., Lim, J. H., et al. (2023) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2023.0282 · Cited by 150
“GLP-1RAs that have shown effects can be used as first-line therapy for NAFLD in T2DM adults (RCT, Limited) [28-30].”
MethodInfluentialContinuous Glucose Monitoring: A Brief Review for Primary Care Practitioners
Ajjan, R., Slattery, D., & Wright, E. (2019) · Advances in Therapy · doi:10.1007/s12325-019-0870-x · Cited by 120
Seidu, S., Kunutsor, S. K., Ajjan, R. A., & Choudhary, P. (2024) · Diabetes Care · doi:10.2337/dc23-1520 · Cited by 124
Janapala, R. N., Jayaraj, J. S., Fathima, N., Kashif, T., Usman, N., Dasari, A., Jahan, N., & Sachmechi, I. (2019) · Cureus · doi:10.7759/cureus.5634 · Cited by 117
“However, some studies reported no significant difference in weight, blood pressure, Problem Areas in Diabetes (PAID) scores, or patient satisfaction [8-9,11].”
BackgroundResultRole of continuous glucose monitoring for type 2 in diabetes management and research
Vigersky, R. A., & Shrivastav, M. (2016) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2016.10.007 · Cited by 127
Self-citationKautzky‐Willer, A., Kosi, L., Lin, J., & Mihaljevic, R. (2015) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12449 · Cited by 112
“Continuous glucose monitoring systems in women may represent an important advancement in the management of both glycaemic control and hypoglycaemia, as use of these devices has improved control and safety [28].”
BackgroundBergenstal, R. M., Layne, J. E., Zisser, H., Gabbay, R. A., Barleen, N. A., Lee, A. A., Majithia, A. R., Parkin, C. G., & Dixon, R. F. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0396 · Cited by 110
Type 2 Diabetes and the Use of Real-Time Continuous Glucose Monitoring
Jackson, M. A., Ahmann, A., & Shah, V. N. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0007 · Cited by 106
“randomized 100 patients with T2D on various therapies, excluding prandial insulin to either usual care or four cycles of rtCGM (Dexcom SEVEN, 2 weeks on/1 week off) over 12 weeks.(23) After 12 weeks, all subjects were followed by their primary care providers for an additional 40 weeks.”
MethodEhrhardt, N., & Al Zaghal, E. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818790994 · Cited by 105
Self-citationTaylor, P. J., Thompson, C. H., & Brinkworth, G. D. (2018) · Journal of Diabetes Investigation · doi:10.1111/jdi.12807 · Cited by 105
Park, C., & Le, Q. A. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0177 · Cited by 104
“16,21,22 FIG.”
Klonoff, D. C., Blonde, L., Cembrowski, G., Chacra, A. R., Charpentier, G., Colagiuri, S., Dailey, G., Gabbay, R. A., Heinemann, L., Kerr, D., et al. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500630 · Cited by 97
Self-citationZahedani, A. D., McLaughlin, T., Veluvali, A., Aghaeepour, N., Hosseinian, A., Agarwal, S., Ruan, J., Tripathi, S., Woodward, M., Hashemi, N., et al. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00956-y · Cited by 96
“…control individuals showed notable TIR improvements, most signi fi cantly in healthy nondiabetics Time in range (TIR) refers to time spent in the following glucose ranges according to previous recommendations: 70 – 180 mg/dL for those with T2D, and 70 – 140 mg/dL for those without T2D 24,25,38 .”
CGMap: Characterizing continuous glucose monitor data in thousands of non-diabetic individuals
Keshet, A., Shilo, S., Godneva, A., Talmor‐Barkan, Y., Aviv, Y., Segal, E., & Rossman, H. (2023) · Cell Metabolism · doi:10.1016/j.cmet.2023.04.002 · Cited by 112
Ida, S., Kaneko, R., & Murata, K. (2019) · Journal of Diabetes Research · doi:10.1155/2019/4684815 · Cited by 86
“Two trials regarding systolic blood pressure were included in the meta-analysis [19, 21], with 77 and 75 pooled subjects in the CGM and SMBG groups, respectively.”
MethodResultThe Cost-Effectiveness of Real-Time Continuous Glucose Monitoring (RT-CGM) in Type 2 Diabetes
Fonda, S. J., Graham, C., Munakata, J., Powers, J. M., Price, D., & Vigersky, R. A. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816628547 · Cited by 81
“The testing data were used to guide health care providers’ decision making, rather than to guide patient decision making, which was the focus of the RT-CGM RCT.”
BackgroundMethodInfluentialSelf-citationPrice, D. A., Deng, Q., Kipnes, M., & Beck, S. E. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01086-y · Cited by 77
“Unlike the Vigersky study [27, 28], the observed HbA1c reduction diminished after rtCGM was withdrawn.”
BackgroundMethodResultUhl, S., Choure, A., Rouse, B., Loblack, A., & Reaven, P. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad652 · Cited by 76
Moon, J. S., Kang, S., Choi, J. H., Lee, K. A., Moon, J. H., Chon, S., Kim, D. J., Kim, H. J., Seo, J. A., Kim, M. K., et al. (2024) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2024.0249 · Cited by 90
Joseph, J. I. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820911919 · Cited by 82
Dehghani Zahedani, A., Shariat Torbaghan, S., Rahili, S., Karlin, K., Scilley, D., Thakkar, R., Saberi, M., Hashemi, N., Perelman, D., Aghaeepour, N., et al. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01081-3 · Cited by 62
“hyperglycemia [14, 23], was used to quantify short-term benefits in daylong glycemia, and clinical factors that predicted improvement in TIR were identified.”
MethodJoubert, M., & Reznik, Y. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.12.010 · Cited by 70
“[38] Ehrhardt NM, Chellappa M, Walker MS, Fonda SJ, Vigersky RA.”
BackgroundTaylor, P. J., Thompson, C. H., Luscombe-Marsh, N. D., Wycherley, T. P., Wittert, G., & Brinkworth, G. D. (2019) · Diabetes Therapy · doi:10.1007/s13300-019-0572-z · Cited by 69
Moon, S. J., Kim, K., Lee, W. J., Lee, M. Y., Vigersky, R., & Park, C. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14852 · Cited by 69
Self-citationContinuous Glucose Monitoring As a Behavior Modification Tool
Ehrhardt, N., & Al Zaghal, E. (2020) · Clinical Diabetes · doi:10.2337/cd19-0037 · Cited by 69
Self-citationWood, A., O'Neal, D., Furler, J., & Ekinci, E. I. (2018) · Internal Medicine Journal · doi:10.1111/imj.13770 · Cited by 67
Grace, T., & Salyer, J. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0212 · Cited by 64
Ji, L., Guo, X., Guo, L., Ren, Q., Yu, N., & Zhang, J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816662884 · Cited by 61
Choe, H. J., Rhee, E.-J., Won, J. C., Park, K. S., Lee, W.-Y., & Cho, Y. M. (2022) · Diabetes Care · doi:10.2337/dc22-0764 · Cited by 59
Majithia, A. R., Kusiak, C. M., Armento Lee, A., Colangelo, F. R., Romanelli, R. J., Robertson, S., Miller, D. P., Erani, D. M., Layne, J. E., Dixon, R. F., et al. (2020) · Journal of Medical Internet Research · doi:10.2196/21778 · Cited by 58
“During the 40-week follow-up period, RCT participants did not use RT-CGM, yet durable improvement in HbA1c was observed at the 52-week follow-up assessment in the RT-CGM group compared with the self-monitoring blood glucose group.”
BackgroundMethodResultInfluentialChamberlain, J. J., Doyle-Delgado, K., Peterson, L., & SKOLNIK, N. (2019) · Annals of Internal Medicine · doi:10.7326/m19-1638 · Cited by 60
Continuous Glucose Monitoring with Multiple Daily Insulin Treatment: Outcome Studies
McGill, J. B., & Ahmann, A. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0090 · Cited by 49
“studied 100 patients with type 2 diabetes using realtime CGM for 2 of every 3 weeks over a 12-week period in a randomized controlled trial.(68) The authors reported a 0.”
Dicembrini, I., Mannucci, E., Monami, M., & Pala, L. (2019) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13845 · Cited by 46
“The present analysis sought to include randomized clinical trials comparing CSII with MDI in type 2 diabetes, as well as those comparing CGM or FGM with SMBG, with a duration of at least 12 weeks of continuous use of CSII or real-time CGM/FGM. Animal studies were excluded.”
MethodInfluentialLu, J., Ying, Z., Wang, P., Fu, M., Han, C., & Zhang, M. (2024) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15328 · Cited by 39
Zhao, C., & Fu, Y. (2015) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2015.04.001 · Cited by 42
“Based on the above analysis, continuous glucose monitoring, as a crucial element of clinical care in diabetes, plays a very important role in glucose management and control[21,22].”
BackgroundIntermittent Use of Continuous Glucose Monitoring: Expanding the Clinical Value of CGM
Ziegler, R., Heinemann, L., Freckmann, G., Schnell, O., Hinzmann, R., & Kulzer, B. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820905577 · Cited by 39
Reddy, M., & Oliver, N. S. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15504 · Cited by 47
Kang, S., Kang, S. M., Choi, J. H., Ko, S., Koo, B. K., Kwon, H.-S., Kim, M. K., Kim, S. Y., Kim, S., Kim, Y., et al. (2025) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2025.0469 · Cited by 85
Tanaka, K., Takahashi, H., Hyogo, H., Ono, M., Oza, N., Kitajima, Y., Kawanaka, M., Chayama, K., Saibara, T., Anzai, K., et al. (2019) · Hepatology Research · doi:10.1111/hepr.13282 · Cited by 37
Sherrill, C. H., Houpt, C. T., Dixon, E. M., & Richter, S. J. (2020) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2020.26.5.600 · Cited by 55
Kong, S.-Y., & Cho, M.-K. (2024) · Healthcare · doi:10.3390/healthcare12050571 · Cited by 36
Kim, J. Y., Jin, S.-M., Sim, K. H., Kim, B.-Y., Cho, J. H., Moon, J. S., Lim, S., Kang, E. S., Park, C.-Y., Kim, S. G., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06152-1 · Cited by 36
Aleppo, G., Hirsch, I. B., Parkin, C. G., McGill, J., Galindo, R., Kruger, D. F., Levy, C. J., Forlenza, G. P., Umpierrez, G. E., Grunberger, G., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0268 · Cited by 34
“%) of the 29 studies reviewed here, investigators reported associations between CGM use and improvements in HbA1c 44–47,54,56–60,62,63,65,67,69,71,75 and/or key CGM metrics.”
BackgroundJohnston, A. R., Poll, J. B., Hays, E., & Jones, C. W. (2022) · Diabetes Epidemiology and Management · doi:10.1016/j.deman.2022.100068 · Cited by 41
García‐Lorenzo, B., Rivero‐Santana, A., Vallejo‐Torres, L., Castilla‐Rodríguez, I., García‐Pérez, S., García‐Pérez, L., & Perestelo‐Pérez, L. (2018) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.12987 · Cited by 39
“37; I(2) = 0%).(38,39,41,43-46,48,49) For T2DM, 5 studies with 2 to 3 months of follow‐up were included in the meta‐analysis (n = 227).”
Kalra, S., Shaikh, S. S., Priya, G., Baruah, M., Verma, A., Das, A. K., Shah, M., Das, S., Khandelwal, D., Sanyal, D., et al. (2020) · Diabetes Therapy · doi:10.1007/s13300-020-00973-0 · Cited by 37
Battelino, T., Lalic, N. M., Hussain, S., Ceriello, A., Majanović, S. K., Davies, S., Topsever, P., Heverly, J., Ulivi, F., Brady, K., et al. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112111 · Cited by 36
Volčanšek, Š., Lunder, M., & Janež, A. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0131 · Cited by 33
Davis, G. M., Bailey, R. J., Calhoun, P. M., Price, D. A., & Beck, R. W. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0489 · Cited by 37
“that modifications in diet, physical activity, and medication adherence motivated by ongoing CGM feedback are important factors in improving glycemic control in this population that may help reduce the need for intensification of treatment regimens.(7,8,11) The primary results of the MOBILE trial confirmed the utility…”
BackgroundResultNorman, G. J., Paudel, M. L., Parkin, C. G., Bancroft, T., & Lynch, P. M. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0525 · Cited by 37
Lau, D., Manca, D. P., Singh, P., Perry, T., Olu-Jordan, I., Ryan Zhang, J., Rahim, G., Hagen, E. M., & Yeung, R. O. (2024) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111899 · Cited by 32
Tan, Y. Y., Suan, E., Koh, G. C. H., Suhairi, S. B., & Tyagi, S. (2024) · Archives of Public Health · doi:10.1186/s13690-024-01459-2 · Cited by 35
Utility of Continuous Glucose Monitoring in Type 1 and Type 2 Diabetes
Toschi, E., & Wolpert, H. A. (2016) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2016.06.003 · Cited by 41
“There are even fewer data available on T2DM and the use of CGM.”
InfluentialAfandi, B. O., Hassanein, M. M., Roubi, S., & Nagelkerke, N. J. D. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.01.036 · Cited by 33
Ajjan, R. A., Abougila, K., Bellary, S., Collier, A., Franke, B., Jude, E. B., Rayman, G., Robinson, A., & Singh, B. M. (2016) · Diabetes and Vascular Disease Research · doi:10.1177/1479164115624680 · Cited by 30
Yingling, L., Allen, N. A., Litchman, M. L., Colicchio, V. D., & Gibson, B. (2019) · JMIR Diabetes · doi:10.2196/12936 · Cited by 33
Continuous glucose monitoring in persons with type 2 diabetes not using insulin
Cowart, K., Updike, W. H., & Franks, R. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1992274 · Cited by 27
“the study by Ehrhardt and colleagues [25] reported rates of hypoglycemia.”
BackgroundDiabetes: the role of continuous glucose monitoring
Kluemper, J. R., Smith, A. C., & Wobeter, B. R. (2022) · Drugs in Context · doi:10.7573/dic.2021-9-13 · Cited by 33
Time-restricted eating improves measures of daily glycaemic control in people with type 2 diabetes
Parr, E. B., Steventon-Lorenzen, N., Johnston, R., Maniar, N., Devlin, B. L., Lim, K., & Hawley, J. A. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110569 · Cited by 35
Fonda, S. J., Salkind, S. J., Walker, M. S., Chellappa, M., Ehrhardt, N. M., & Vigersky, R. A. (2013) · Diabetes Care · doi:10.2337/dc12-1225 · Cited by 29
Self-citationFonda, S. J., Lewis, D. G., & Vigersky, R. A. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700110 · Cited by 30
Self-citationAronson, R., Abitbol, A., Bajaj, H. S., Cheng, A. Y. Y., Christopoulos, S., Harris, S. B., Jain, A. B., & Goldenberg, R. M. (2025) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.70008 · Cited by 33
“Fonda and colleagues 59 reported on the cost-effectiveness of the periodic rtCGM intervention previously reported by Ehrhardt et al. 33 Based on 2011 pricing, they found that intermittent rtCGM was a cost-effective option, with incremental cost-effectiveness ratios of $9319 and $13 030 per (life…”
Zavitsanou, S., MASSA, J. S., Deshpande, S., Pinsker, J. E., Church, M. M., ANDRE, C. C., Doyle, F. J., Michelson, A., Creason, J., Dassau, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0109 · Cited by 28
Kruger, D. F., & Anderson, J. E. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0193 · Cited by 30
“49 In an economic analysis of this cohort, CGM was found to be cost-effective, and that repeated CGM use would likely result in additional cost savings.”
Glycaemic control in people with diabetes following acute myocardial infarction
Esdaile, H., Hill, N. E., Mayet, J., & Oliver, N. S. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110644 · Cited by 32
Isaacson, B., Kaufusi, S., Sorensen, J., Joy, E. A., Jones, C., Ingram, V., Mark, N., Phillips, M., & Briesacher, M. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820955228 · Cited by 26
Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes
Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D. (2023) · Endocrine Connections · doi:10.1530/ec-23-0085 · Cited by 22
Taylor, P. J., Thompson, C. H., Luscombe‐Marsh, N. D., Wycherley, T. P., Wittert, G., Brinkworth, G. D., & Zajac, I. T. (2019) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2019.107814 · Cited by 25
Cyclodextrin Host–Guest Recognition in Glucose-Monitoring Sensors
Javanbakht, S., Darvishi, S., Dorchei, F., Ghalehno, M. H., Dehghani, M., Pooresmaeil, M., Suzuki, Y., Ain, Q., Ruiz‐Rubio, L., Shaabani, A., et al. (2023) · ACS Omega · doi:10.1021/acsomega.3c03746 · Cited by 22
Reed, J., Dong, T., Eaton, E., Friswold, J., Porges, J., Al‐Kindi, S. G., Rajagopalan, S., & Neeland, I. J. (2024) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15608 · Cited by 22
Zou, Y. L., Zhao, S., Li, G., & Zhang, C. (2022) · Journal of General Internal Medicine · doi:10.1007/s11606-022-07864-z · Cited by 27
Tildesley, H. D., Wright, A. M., Chan, J. H. M., Mazanderani, A. B., Ross, S. A., Tildesley, H. G., Lee, A. M., Tang, T. S., & White, A. S. (2013) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2013.05.006 · Cited by 20
“Although the majority of studies have been conducted on patients with type 1 diabetes (8,15), RT-CGM has been shown to improve glycemic awareness even without clinical intervention (11) and also may convey additional benefits by reducing hypoglycemic exposure (8) and post-prandial hyperglycemic excursions (15).”
BackgroundRetracted
Metadata
- Authors
- Ehrhardt, N. M., Chellappa, M., Walker, M. S., Fonda, S. J., & Vigersky, R. A.
- Affiliations
- Walter Reed National Military Medical Center (US)
- Corresponding author
- Vigersky, Robert A.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2011-05
- Volume
- 5
- Issue
- 3
- Pages
- 668-675
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC3192632
- OpenAlex
- W2071796315
- Semantic Scholar
- ee10abe8dc890b07dc22a377ef7bb8da317eadb2
- Cited by
- 199
- References
- 30
- Citations by year
- 2026: 10 · 2025: 20 · 2024: 18 · 2023: 26 · 2022: 22 · 2021: 21 · 2020: 14 · 2019: 18 · 2018: 12 · 2017: 9 · 2016: 10 · 2015: 2 · 2013: 5 · 2012: 6
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- real-time continuous glucose monitoring, type 2 diabetes, glycemic control, HbA1c, self-monitoring of blood glucose, non-insulin-treated diabetes, hypoglycemia
- MeSH terms
- Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Insulin, Male, Middle Aged, Prospective Studies, Regression Analysis, Blood Glucose Self-Monitoring, Treatment Outcome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.