System Accuracy Evaluation of 43 Blood Glucose Monitoring Systems for Self-Monitoring of Blood Glucose according to DIN EN ISO 15197
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Background: The accuracy of systems for self-monitoring of blood glucose is important, as reliable measurement results are a prerequisite for therapeutic decisions. Methods: This system accuracy evaluation study was performed according to DIN EN ISO 15197:2003 for 43 Conformité Européenne (CE)-labeled blood glucose (BG) monitoring systems. Measurement results of each system were compared with results of the designated comparison method (manufacturer's measurement procedure): glucose oxidase method (YSI 2300 glucose analyzer) or hexokinase method (Hitachi 917/ cobas 501). Results: Complete assessment according to the International Organization for Standardization (ISO) standard was performed for 34 out of 43 systems, and 27 (79.4%) meet the requirements of the standard, i.e., ≥95% of their results showed at least the minimum acceptable accuracy. For 9 of the 43 systems, complete accuracy assessment was not performed due to an oxygen sensitivity (manufacturer's labeling). The bias (according to Bland and Altman) of all 43 evaluated systems ranged from −14.1% to +12.4%. Conclusions: From the 34 systems completely assessed, 7 systems did not fulfill the minimal accuracy requirements of the ISO standard. The CE mark apparently does not guarantee that all BG systems provide accuracy according to the standard. Because inaccurate systems bear the risk of false therapeutic decisions, regular and standardized evaluation of BG meters and test strips should be requested in order to ensure adherence to quality standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The current requirement of traceability according to ISO 17511 as stated by ISO 15197, without specifying further requirements or performance goals, might be insufficient in light of the considerable systematic differences between measurement procedures observed in this and other studies.21,33”
From Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems (2022) · cites this paper as [33]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Yet, only a few studies investigated possible systematic differences between different comparison methods (GOD or HK) or measurement procedures up to now, whereas a bias of up to 8% between the different comparison measurement procedures has been reported.21,31-35”
From Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems (2022) · cites this paper as [33]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Nevertheless, several evaluation or surveillance studies within recent years repeatedly revealed that a non-negligible number of CE-marked BGMS, which do not fulfill the minimum accuracy criteria of ISO 15197, had been or currently still are on sale on the European market.12–14”
From System accuracy evaluation of 18 CE-marked current-generation blood glucose monitoring systems based on EN ISO 15197:2015 (2020) · cites this paper as [13]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
(2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 699
Global guideline for type 2 diabetes: recommendations for standard, comprehensive, and minimal care
IDF Clinical Guidelines Task Force (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2006.01918.x · Cited by 433
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Petersen, B., Schweitzer, M., & Wagner, R. S. (2011) · Diabetes Care · doi:10.2337/dc10-1732 · Cited by 429
Factors affecting blood glucose monitoring: sources of errors in measurement
Ginsberg, B. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300438 · Cited by 348
Martin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284
Approved IFCC recommendation on reporting results for blood glucose (abbreviated)
D'Orazio, P. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051979 · Cited by 208
Research works printed but not linked: 2
- 17. Bundesärztekammer. Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen. Dtsch Ärztebl. 2008;105(7):341-55.
- 23. Freckmann G, Haug C, Heinemann L. Blutzuckerselbstmessung heute: Sind alle Geräte gleich? Diabetes Stoffwechsel Herz. 2011;20(4):235-41.
Cited by
Items 201–244 of 244
Freedom of Science – Can Industry Influence What Scientists Publish?
Ziegler, R., Schnell, O., Kulzer, B., Gilbart, J., Heinemann, L., & Chief Executive Officer, S. &. C. (2010) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2014.10.01.i · Cited by 1
How to evaluate over 60 million blood glucose data — The design of the MÉRY Diabetes Database
Hermányi, Z., Csiki, V., Menyhárt, A., Osgyán, K., Körei, A. E., Istenes, I., Putz, Z., Benhamida, A., Berey, A., Hetthéssy, J. R., et al. (2023) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2023.108586 · Cited by 1
Paper‐Based Device for Phenolic Content Determination in Tea Extracts
Silver, R. A., Noviana, E., Shiddiq, M. A. A., Wardani, N. K., Windarsih, A., Indrasyah, F. S., Fakhrudin, N., Indrianingsih, A. W., & Henry, C. S. (2024) · Phytochemical Analysis · doi:10.1002/pca.3494 · Cited by 1
Quality, control and validation of glucometers and CGM systems. Status overview
Friedecky, B., Kratochvíla, J., & Springer, D. (2016) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2016.013 · Cited by 2
The Standard of Analytical Quality of Glucometers
Friedecky, B., Springer, D., & Kratochvíla, J. (2014) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2014.015 · Cited by 2
Freedom of Speech and Science: Can Companies Force Us to Withdraw Data They Don't Like?
Heinemann, L., & Klonoff, D. C. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700501 · Cited by 1
Approaches to Display of Multiple-Point Glucose Profiles: A UK Patient’s Perspective
Kay, D. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814541245
On the Bus or Under the Bus? The Current Healthcare System is Endangering Elderly Diabetes Patients
Parkin, C. G. (2015) · Journal of Diabetes Metabolic Disorders & Control · doi:10.15406/jdmdc.2015.02.00028
Grunberger, G., Abelseth, J. M., Bailey, T. S., Bode, B. W., Handelsman, Y., Hellman, R., Lane, W. S., Raskin, P., Tamborlane, W. V., & Rothermel, C. (2014)
In search of accuracy for blood glucose monitoring
Meetoo, D. D. (2016) · British Journal of Healthcare Management · doi:10.12968/bjhc.2016.22.2.52
Romo-Cárdenas, G. S., Sanchez-Lopez, J. D., Hipólito, J. I. N., Cosío-León, M. D. L. Á., Luque, P. A., & Vázquez-Briseño, M. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2235805
“Besides, a recent study found that some of these devices might not comply with the requirements for the acquisition of a safe blood glucose concentration measurements [8].”
BackgroundIn search of accuracy for blood glucose monitoring
Meetoo, D. D. (2016) · Independent Nurse · doi:10.12968/indn.2016.16.22
Андрианова, Е. А., Il'yin, A. V., Kuraeva, T. L., & Peterkova, V. A. (2017) · Problems of Endocrinology · doi:10.14341/probl201763117-22
Potenziale für POCT im Internet of Things (IoT)
Rode-Schubert, C., Norgall, T., & Bietenbeck, A. (2017) · Springer eBooks · doi:10.1007/978-3-662-54196-8_42
The reliability of blood glucose point-of-care testing (POCT) system in China teaching hospital
Ma, J. (2017) · International Journal of Hematology and Therapy · doi:10.15436/2381-1404.17.1546
Almarshad, H. A. (2017) · JOURNAL OF ADVANCES IN BIOTECHNOLOGY · doi:10.24297/jbt.v6i3.6262
“Previous stud-ies [16],[17] & [18] indicated that the accuracy variations of glucose measurements Hypoglyce mia 3%”
Význam četnosti kalibrace systému pro kontinuální monitorování glykémie na přesnost výsledků měření
Folwarczny, M. (2017) · DSpace VŠB-TUO (VŠB-TUO)
GlucoPush: A Do-It-Yourself Add-On for Online Tracking of Personal Glucometer UsePreprint
Soenksen, L. R., & Mamat, Z. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/296293
“Current clinical guidelines recommend frequent SMBG for most diabetic patients to guide insulin control therapy, physical activity and food intake [2].”
BackgroundAlgorithm for offline recalibration of recorded CGM traces
Reiterer, F., Zeindl, H. P., & del Re, L. (2018) · Middle East Conference on Biomedical Engineering · doi:10.1109/mecbme.2018.8402439
“[27] for information about measurement errors of BG meters).”
BackgroundThe next steps in diabetes care for the UK: The White Paper
Phillips, A. (2018) · Practice Nursing · doi:10.12968/pnur.2018.29.12.584
AVALIAÇÃO DE TRÊS SENSORES PORTÁTEIS VETERINÁRIOS PARA A MENSURAÇÃO DE GLICEMIA EM FELINOS
Pellegrino, M., Passos, S. K. P., Alves, G., Paes, P., & Bicalho, A. P. D. C. V. (2020) · Enciclopédia Biosfera · doi:10.18677/encibio_2020b10
Kochin, I. V., Khandoga, E. V., & Остапенко, А. (2020) · EMERGENCY MEDICINE · doi:10.22141/2224-0586.8.103.2019.192366
Consequences of SMBG systems inaccuracy
Campos-Náñez, E., & Fortwaengler, K. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816714-4.00004-1
Self-monitoring of blood glucose as an essential component of exerting total control over diabetes
Biryukova, E. V. (2014) · Cardiosomatics · doi:10.26442/cs45069
Freire, Y. A., Silva, C. A., Macêdo, G. A. D., Browne, R. A. V., de Oliveira, B. M., Martins, G. F. C., Farias-Junior, L. F., Brito, L. C., & Costa, E. C. (2021) · Journal of Aging and Physical Activity · doi:10.1123/japa.2020-0418
Diagnosis and Management of Pediatric Diseases
Sergi, C. M. (2019) · MDPI eBooks · doi:10.3390/books978-3-03921-967-4
Valenza clinica delle norme ISO per i device per l’autocontrollo glicemico
Ceriello, A. (2015) · MEDIA - Aggiornamento e formazione in diabetologia e malattie metaboliche
Hypoglycemia Detection in Diabetes
Richardson, J. M., & Shaginian, R. M. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.103137
Дмитриевич, З. В., & Mustafina, V. R. (2022) · Medical Herald of the South of Russia · doi:10.21886/2219-8075-2022-13-1-43-51
“Современные портативные тест-системы дают возможность людям с диабетом самостоятельно оценивать важнейшие параметры обмена веществ в условиях повседневной жизни с точностью, близкой к лабораторной [2], что имеет большое значение для подбора терапии.”
Viele Blutzuckermessgeräte erfüllen Mindestanforderungen an Messqualität nicht
(2013) · Info Diabetologie · doi:10.1007/s15034-013-0364-x
Rott, H., & Koschinsky, T. (2017) · Springer eBooks · doi:10.1007/978-3-662-54196-8_33
da Luz, C. M. (2022) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.17.2022.tde-11042023-092004
de Souza, A. B. C. (2022) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.5.2022.tde-17042023-113357 · Cited by 1
Medical device standardisation for diabetes: a 6–year evaluation of cost savings
Swift, J., Abed, S., Hall, J. J., Cheung, J., Pearson, K., & Baker, C. (2023) · British Journal of Healthcare Management · doi:10.12968/bjhc.2021.0160
MESA 2: INNOVACIONES TECNOLÓGICAS EN EL TRATAMIENTO DE LA DIABETES MELLITUS TIPO 1
Morosini, M. L. R., PROIETTI, A. E., Ré, M., Schindler, A., Medek, G., Dios, A. D., Larreburo, S. V., Mengoni, K., González, L. S., Méndez, J., et al. (2023) · Revista de la Sociedad Argentina de Diabetes · doi:10.47196/diab.v49i3.634
Jenie, R. P., Adibah, R., Aridarma, A., Rahayu, S., Dahrul, M., Irzaman, I., & Alatas, H. (2025) · Journal of Advanced Research in Applied Sciences and Engineering Technology · doi:10.37934/araset.64.2.119
“EGA measures use the EGA, R, Rstudio and LibreOffice Calc libraries, according to research [14].”
InfluentialCosmas, F. N., Urioa, F. H., & Mbugi, E. V. (2025) · East Africa Science · doi:10.24248/easci.v7i1.122
Multi-Radar Bio-Sensor Fusion for Real-Time, Distributed Sensing
Bagheri, M. O., Chow, J., Ramahi, O. M., & Shaker, G. S. A. (2025) · Digest - IEEE Antennas and Propagation Society. International Symposium · doi:10.1109/ap-s/cnc-usnc-ursi55537.2025.11266204
“This delay, coupled with the dynamic nature of glucose transport, can lead to variability even between consecutive measurements on the same meter [19].”
Patientenselbsttestung – Blutzucker und kontinuierliches Glukosemonitoring
Freckmann, G., Luppa, P. B., & Waldenmaier, D. (2025) · Springer eBooks · doi:10.1007/978-3-662-71315-0_32
Self-citationAutomatic Processing of Stimuli in Relation to Short-Term Hunger
Vare, R. (2026) · DSpace repository (University of Tartu)
Baghous, H., Aouiche, S., & AZZOUG, S. (2026) · IOSR Journal of Dental and Medical Sciences · doi:10.9790/0853-2503024960
Kaczmarski, M., Kamiński, P., Surdacka, L., Jagiełło, J. K., Jakubas, A., Iwanicka, K. A., Pawelec, K., & Jóźwiak, S. M. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.2(50).2026.5663
Abbott, K. C. (2014) · Scholarship@Western (Western University)
Metadata
- Authors
- Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C.
- Affiliations
- Universität Ulm (DE)
- Corresponding author
- Freckmann, Guido
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2012-09
- Volume
- 6
- Issue
- 5
- Pages
- 1060-1075
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC3570840
- OpenAlex
- W2153556745
- Semantic Scholar
- f51002e49bd0efca6a14d70d53eb7f2e22fb03d4
- Cited by
- 237
- References
- 36
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 9 · 2023: 13 · 2022: 8 · 2021: 11 · 2020: 16 · 2019: 19 · 2018: 30 · 2017: 28 · 2016: 23 · 2015: 22 · 2014: 31 · 2013: 20 · 2012: 1
- FWCI
- 18.99
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- self-monitoring of blood glucose, blood glucose meters, test strips, measurement accuracy, CE marking, glucose oxidase method, hexokinase method, bias, diabetes management
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Blood Glucose, Diabetes Mellitus, Equipment and Supplies, European Union, Female, Humans, Insulin Infusion Systems, Male, Middle Aged, Oxygen, Reference Standards, Blood Glucose Self-Monitoring, Reproducibility of Results, Device Approval, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.