System Accuracy Evaluation of 43 Blood Glucose Monitoring Systems for Self-Monitoring of Blood Glucose according to DIN EN ISO 15197
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Background: The accuracy of systems for self-monitoring of blood glucose is important, as reliable measurement results are a prerequisite for therapeutic decisions. Methods: This system accuracy evaluation study was performed according to DIN EN ISO 15197:2003 for 43 Conformité Européenne (CE)-labeled blood glucose (BG) monitoring systems. Measurement results of each system were compared with results of the designated comparison method (manufacturer's measurement procedure): glucose oxidase method (YSI 2300 glucose analyzer) or hexokinase method (Hitachi 917/ cobas 501). Results: Complete assessment according to the International Organization for Standardization (ISO) standard was performed for 34 out of 43 systems, and 27 (79.4%) meet the requirements of the standard, i.e., ≥95% of their results showed at least the minimum acceptable accuracy. For 9 of the 43 systems, complete accuracy assessment was not performed due to an oxygen sensitivity (manufacturer's labeling). The bias (according to Bland and Altman) of all 43 evaluated systems ranged from −14.1% to +12.4%. Conclusions: From the 34 systems completely assessed, 7 systems did not fulfill the minimal accuracy requirements of the ISO standard. The CE mark apparently does not guarantee that all BG systems provide accuracy according to the standard. Because inaccurate systems bear the risk of false therapeutic decisions, regular and standardized evaluation of BG meters and test strips should be requested in order to ensure adherence to quality standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The current requirement of traceability according to ISO 17511 as stated by ISO 15197, without specifying further requirements or performance goals, might be insufficient in light of the considerable systematic differences between measurement procedures observed in this and other studies.21,33”
From Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems (2022) · cites this paper as [33]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Yet, only a few studies investigated possible systematic differences between different comparison methods (GOD or HK) or measurement procedures up to now, whereas a bias of up to 8% between the different comparison measurement procedures has been reported.21,31-35”
From Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems (2022) · cites this paper as [33]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Nevertheless, several evaluation or surveillance studies within recent years repeatedly revealed that a non-negligible number of CE-marked BGMS, which do not fulfill the minimum accuracy criteria of ISO 15197, had been or currently still are on sale on the European market.12–14”
From System accuracy evaluation of 18 CE-marked current-generation blood glucose monitoring systems based on EN ISO 15197:2015 (2020) · cites this paper as [13]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
(2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 699
Global guideline for type 2 diabetes: recommendations for standard, comprehensive, and minimal care
IDF Clinical Guidelines Task Force (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2006.01918.x · Cited by 433
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Petersen, B., Schweitzer, M., & Wagner, R. S. (2011) · Diabetes Care · doi:10.2337/dc10-1732 · Cited by 429
Factors affecting blood glucose monitoring: sources of errors in measurement
Ginsberg, B. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300438 · Cited by 348
Martin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284
Approved IFCC recommendation on reporting results for blood glucose (abbreviated)
D'Orazio, P. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051979 · Cited by 208
Research works printed but not linked: 2
- 17. Bundesärztekammer. Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen. Dtsch Ärztebl. 2008;105(7):341-55.
- 23. Freckmann G, Haug C, Heinemann L. Blutzuckerselbstmessung heute: Sind alle Geräte gleich? Diabetes Stoffwechsel Herz. 2011;20(4):235-41.
Cited by
Universal mobile electrochemical detector designed for use in resource-limited applications
Nemiroski, A., Christodouleas, D. C., Hennek, J. W., Kumar, A. A., Maxwell, E. J., Fernández-Abedul, M. T., & Whitesides, G. M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1405679111 · Cited by 285
“Although useful in a variety of settings, these methods— with the important exception of blood glucose meters (3, 4)—are generally limited to well-resourced laboratories run by skilled personnel.”
MethodWadwa, R. P., Laffel, L. M., Shah, V. N., & Garg, S. K. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0150 · Cited by 198
Hybrid nanostructures for SERS: materials development and chemical detection
Fateixa, S., Nogueira, H. I. S., & Trindade, T. (2015) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp01032b · Cited by 197
Klonoff, D. C., Lias, C., Vigersky, R., Clarke, W., Parkes, J. L., Sacks, D. B., Kirkman, M. S., Kovatchev, B., Panel, T. E. G., Aurand, L., et al. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814539589 · Cited by 174
Directed evolution 2.0: improving and deciphering enzyme properties
Cheng, F., Zhu, L., & Schwaneberg, U. (2015) · Chemical Communications · doi:10.1039/c5cc01594d · Cited by 177
Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168
Factory-Calibrated Continuous Glucose Sensors: The Science Behind the Technology
Hoss, U., & Budiman, E. S. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0025 · Cited by 142
Challenges and perspectives in continuous glucose monitoring
van Enter, B. J., & von Hauff, E. (2018) · Chemical Communications · doi:10.1039/c8cc01678j · Cited by 154
Significance and Reliability of MARD for the Accuracy of CGM Systems
Reiterer, F., Polterauer, P., Schoemaker, M., Schmelzeisen-Redecker, G., Freckmann, G., Heinemann, L., & del Re, L. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816662047 · Cited by 124
Self-citationBailey, T. S., Grunberger, G., Bode, B. W., Handelsman, Y., Hirsch, I. B., Jovanovič, L., Roberts, V. L., Rodbard, D., Tamborlane, W. V., & Walsh, J. S. A. (2016) · Endocrine Practice · doi:10.4158/ep151124.cs · Cited by 151
Comparative accuracy of 17 point-of-care glucose meters
Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816672237 · Cited by 127
Ajjan, R. A., Cummings, M. H., Jennings, P., Leelarathna, L., Rayman, G., & Wilmot, E. G. (2018) · Diabetes and Vascular Disease Research · doi:10.1177/1479164118756240 · Cited by 111
Glucose Sensing Using Surface-Enhanced Raman-Mode Constraining
Yang, D., Afroosheh, S., Lee, J. O., Cho, H., Kumar, S., Siddique, R. H., Narasimhan, V., Yoon, Y.-Z., Zayak, A. T., & Choo, H. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03420 · Cited by 111
Klatman, E. L., Jenkins, A. J., Ahmedani, M. Y., & Ogle, G. D. (2019) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(18)30074-3 · Cited by 100
Review of present method of glucose from human blood and body fluids assessment
Fiedorova, K., Augustýnek, M., Kubíček, J., Kudrna, P., & Bibbo, D. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114348 · Cited by 103
Tu, H., Li, H., Wang, Y., Niyyati, M., Wang, Y., Leshin, J., & Levine, M. (2015) · EBioMedicine · doi:10.1016/j.ebiom.2015.09.049 · Cited by 89
“Values between methods used for mouse and human samples are within 10% (Freckmann et al., 2012).”
MethodRajendran, R., & Rayman, G. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814538940 · Cited by 84
“Of greater concern was once approved (by Communauté Européenne [CE] in Europe or FDA in the United States) many of the existing meters (both hospital and outpatient use) failed to maintain the original standard.(60-65) Most clinicians and patients are unaware of this.”
BackgroundLuppa, P. B., Bietenbeck, A., Beaudoin, C. A., & Giannetti, A. E. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.01.003 · Cited by 104
Baumstark, A., Pleus, S., Schmid, C., Link, M., Haug, C., & Freckmann, G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600511 · Cited by 90
Self-citationContinuous Glucose Monitoring: Evidence and Consensus Statement for Clinical Use
Liebl, A., Henrichs, H. R., Heinemann, L., Freckmann, G., Biermann, E., Thomas, A., & for the Continuous Glucose Monitoring Working Group of the Working Group Diabetes Technology of the German Diabetes Association (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700227 · Cited by 77
Self-citationMassa, G. G., Gys, I., Op ‘t Eyndt, A., Bevilacqua, E., Wijnands, A., Declercq, P., & Zeevaert, R. (2018) · Hormone Research in Paediatrics · doi:10.1159/000487361 · Cited by 73
Current Diabetes Technology: Striving for the Artificial Pancreas
Allen, N., & Gupta, A. (2019) · Diagnostics · doi:10.3390/diagnostics9010031 · Cited by 65
“With typical home glucometer use, there is approximately a 20% margin of error for BG measurements [16].”
BackgroundPleus, S., Baumstark, A., Jendrike, N., Mende, J., Link, M., Zschornack, E., Haug, C., & Freckmann, G. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001067 · Cited by 63
Self-citationCould Age, Sex and Physical Fitness Affect Blood Glucose Responses to Exercise in Type 1 Diabetes?
Yardley, J. E., Brockman, N. K., & Bracken, R. M. (2018) · Frontiers in Endocrinology · doi:10.3389/fendo.2018.00674 · Cited by 67
“Improvements in the accuracy of hand-held glucose monitors to meet ISO criteria (5) and continuous glucose monitoring systems (CGM) (6, 7) have made this progress possible.”
BackgroundMalhotra, S., Cheriff, A. D., Gossey, J. T., Cole, C. L., Kaushal, R., & Ancker, J. S. (2016) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv192 · Cited by 68
Nanditha, A., Snehalatha, C., Satheesh, K., Susairaj, P., Simon, M., Vijaya, L., Raghavan, A., Vinitha, R., & Ramachandran, A. (2019) · Diabetes Care · doi:10.2337/dc18-1559 · Cited by 74
“cose was measured at fasting and at 2 h after consumption of 75 g oral glucose, using venous blood and Accu-Chek Performa (Roche Diagnostics, GmbH, Germany) by the hexokinase method and calibrated to read plasma glucose (24).”
MethodPerformance of Cleared Blood Glucose Monitors
Klonoff, D. C., & Prahalad, P. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815584797 · Cited by 59
Reengineered glucose oxidase for amperometric glucose determination in diabetes analytics
Gutierrez, E. A., Mundhada, H., Meier, T., Duefel, H., Bocola, M., & Schwaneberg, U. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.06.029 · Cited by 62
“(E. Arango Gutierrez), er.tm4@roche.com (T. Meier), erg). glucose dehydrogenases (GDH's) are most commonly used in diabetes care due to their specificity and activity (Freckmann et al., 2012; Hoenes et al., 2008).”
BackgroundFottner, C., Ferrata, M., & Weber, M. M. (2017) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-017-9438-8 · Cited by 70
“stressed that the accuracy of systems for self-monitoring of blood glucose have been proven not to be optimal and laboratory measurement may be desirable in all cases [38].”
BackgroundFeasibility of Factory Calibration for Subcutaneous Glucose Sensors in Subjects With Diabetes
Hoss, U., Budiman, E. S., Liu, H., & Christiansen, M. P. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813511747 · Cited by 53
General-purpose passive wireless point–of–care platform based on smartphone
Escobedo, P., Erenas, M. M., Martínez-Olmos, A., Carvajal, M. A., González-Chocano, S., Capitán-Vallvey, L. F., & Palma, A. J. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111360 · Cited by 54
Blackwell, M., & Wheeler, B. J. (2016) · Acta Diabetologica · doi:10.1007/s00592-016-0907-4 · Cited by 56
Variability of capillary blood glucose monitoring measured on home glucose monitoring devices
Kotwal, N., & Pandit, A. (2012) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/2230-8210.104052 · Cited by 54
“In a recent study in 2012 of 43 glucose meters, only 34 systems met ISO standards.[4] A recent study in April 2012 of two new glucometers demonstrated high accuracy compared to Mini Review”
ResultThe vast repertoire of carbohydrate oxidases: An overview
Savino, S., & Fraaije, M. W. (2020) · Biotechnology Advances · doi:10.1016/j.biotechadv.2020.107634 · Cited by 56
“mate with dehydrogenases (Freckmann et al., 2012), which have also been studied and enhanced to be used as biosensors (Arango Gutierrez et al.”
BackgroundGlucose monitoring in neonates: need for accurate and non-invasive methods
Woo, H. C., Tolosa, L. M., El‐Metwally, D., & Viscardi, R. M. (2013) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2013-304682 · Cited by 49
Detection of saliva-range glucose concentrations using organic thin-film transistors
Elkington, D. C., Belcher, W. J., Dastoor, P. C., & Zhou, X. (2014) · Applied Physics Letters · doi:10.1063/1.4892012 · Cited by 48
Computing the Surveillance Error Grid Analysis: Procedure and Examples
Kovatchev, B. P., Wakeman, C. A., Breton, M. D., Kost, G. J., Louie, R. F., Tran, N. K., & Klonoff, D. C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814539590 · Cited by 47
“674 Journal of Diabetes Science and Technology 8(4)”
BackgroundMethodInfluentialKirchsteiger, H., Heinemann, L., Freckmann, G., Lodwig, V., Schmelzeisen-Redeker, G., Schoemaker, M., & del Re, L. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815586013 · Cited by 45
“The latter also differ significantly themselves in their measurement error.(18) As this error is included in the computed MARD value but has no relationship to the CGM system studied, it is important to know this error to be able to make a statement about the real accuracy of the CGM system.”
BackgroundResultSelf-citationHiraka, K., Kojima, K., Lin, C.-E., Tsugawa, W., Asano, R., Belle, J. T. L., & Sode, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.12.018 · Cited by 49
Klaff, L. J., Brazg, R., Hughes, K., Tideman, A. M., Schachner, H. C., Stenger, P., Pardo, S., Dunne, N., & Parkes, J. L. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0069 · Cited by 46
Limits to the Evaluation of the Accuracy of Continuous Glucose Monitoring Systems by Clinical Trials
Schrangl, P., Reiterer, F., Heinemann, L., Freckmann, G., & Del Re, L. (2018) · Biosensors · doi:10.3390/bios8020050 · Cited by 46
“extracted from a finger tip (see [2] for an overview on the current market).”
BackgroundSelf-citationLo, J. C., Twan, D. C. K., Karamchedu, S., Lee, X. K., Ong, J. L., Van Rijn, E., Gooley, J. J., & Chee, M. W. L. (2019) · Sleep · doi:10.1093/sleep/zsz037 · Cited by 44
“The meter meets the ISO 15197 requirements for in vitro diagnostic test systems for blood-glucose monitoring systems for self-testing in managing diabetes (≥95% of the system measurement results must fall within ±15 mg/dL of the results of the manufacturer’s measurement procedure at glucose concentrations <100 mg/dL a…”
BackgroundRSSDI consensus on self-monitoring of blood glucose in types 1 and 2 diabetes mellitus in India
Rao, P., Makkar, B. M., Kumar, A., Das, A. K., Singh, A. K., Mithal, A., Bhansali, A., Misra, A., Maheshwari, A., Gupta, A., et al. (2018) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-018-0677-3 · Cited by 49
Alyami, J., Whitehouse, E., Yakubov, G. E., Pritchard, S. E., Hoad, C. L., Blackshaw, E., Heissam, K., Cordon, S. M., Bligh, H. F. J., Spiller, R. E., et al. (2019) · British Journal Of Nutrition · doi:10.1017/s0007114519001880 · Cited by 42
“2) via fingerpricking using single-use lancets (Unistix Owen Mumford) andmeasured using a hand-held device (Accu-Check; Roche Diagnostics)(48).”
MethodReusch, C. E. (2015) · Elsevier eBooks · doi:10.1016/b978-1-4557-4456-5.00007-9 · Cited by 51
A review of blood glucose monitor accuracy
King, F., Ahn, D., Hsiao, V., Porco, T., & Klonoff, D. C. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0232 · Cited by 37
Alyami, J., Ladd, N., Pritchard, S. E., Hoad, C. L., Sultan, A. A., Spiller, R. E., Gowland, P. A., Macdonald, I. A., Aithal, G. P., Marciani, L., et al. (2017) · Food Research International · doi:10.1016/j.foodres.2017.11.071 · Cited by 38
Boettcher, C., Dost, A., Wudy, S. A., Flechtner-Mors, M., Borkenstein, M., Schiel, R., Weitzel, D., Bechtold-Dalla Pozza, S., Wolf, J., Holl, R. W., et al. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0262 · Cited by 35
Ranamukhaarachchi, S. A., Padeste, C., Häfeli, U. O., Stoeber, B., & Cadarso, V. J. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa9c9c · Cited by 35
“2 the blood glucose concentration target for most diabetic patients ranges from 4 to 7 mM [6], and is monitored in capillary blood samples [7].”
BackgroundNanopatterned Bulk Metallic Glass Biosensors
Kinser, E. R., Padmanabhan, J., Yu, R., Corona, S. L., Li, J., Vaddiraju, S., Legassey, A., Loye, A. M., Balestrini, J. L., Solly, D. A., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00455 · Cited by 36
Shafouri, N. S. T. A., Narvey, M. R., Srinivasan, G., Vallance, J. K., & Hansen, G. (2015) · Journal of Neonatal-Perinatal Medicine · doi:10.3233/npm-15814107 · Cited by 34
Nanditha, A., Susairaj, P., Satheesh, K., Raghavan, A., Snehalatha, C., & Ramachandran, A. (2024) · Journal of Diabetes · doi:10.1111/1753-0407.13576 · Cited by 34
Current concepts in blood glucose monitoring
Khadilkar, K., Bandgar, T., Shivane, V. K., Lila, A. R., & Shah, N. S. (2013) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/2230-8210.123556 · Cited by 34
“The ISO: 15197 standards discuss quality standards in blood glucose monitoring devices and the accuracy requirements for glucometers.[24] This standard states that 95% of comparative results between a laboratory reference and the glucometer must fall within a bias of 15% for results greater than 100 mg%.”
Hassan, N. A., El‐Bassossy, H. M., Fahmy, A., & Mahmoud, M. F. (2018) · Phytomedicine · doi:10.1016/j.phymed.2018.03.044 · Cited by 32
Accuracy Evaluation of Five Blood Glucose Monitoring Systems: The North American Comparator Trial
Halldorsdottir, S., Warchal-Windham, M. E., Wallace, J. F., Pardo, S., Parkes, J. L., & Simmons, D. A. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700520 · Cited by 31
Ostafe, R., Fontaine, N., Frank, D., Chong, M. N. F., Prodanović, R., Pandjaitan, R., Offmann, B., Cadet, F., & Fischer, R. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27169 · Cited by 31
Near-optimal insulin treatment for diabetes patients: A machine learning approach
Shifrin, M., & Siegelmann, H. T. (2020) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2020.101917 · Cited by 35
Evaluation of a flash glucose monitoring system in dogs with diabetic ketoacidosis
Silva, D. D., Cecci, G. R. M., Biz, G., Chiaro, F. N., & Zanutto, M. D. S. (2020) · Domestic Animal Endocrinology · doi:10.1016/j.domaniend.2020.106525 · Cited by 31
Budiman, E. S., Samant, N., & Resch, A. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700213 · Cited by 30
ISO-Based Assessment of Accuracy and Precision of Glucose Meters in Dogs
Brito‐Casillas, Y., Figueirinhas, P., Wiebe, J. C., López-Ríos, L., Perez-Barreto, D., Melián, C., & Wägner, A. M. (2014) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12397 · Cited by 34
“Most of the devices analyzed in this study fulfill the ISO 15197:2003 and 2013 for human capillary blood.(12,13) We are not aware of a known explanation for this interspecies gap in accuracy, but given the difference in performance between WB and plasma samples, we suggest that the cellular fraction must contain the s…”
MethodKermani, S. K., Khatony, A., Jalali, R., Rezaei, M., & Abdi, A. (2017) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2017/23926.9613 · Cited by 37
Mean Absolute Relative Difference of Blood Glucose Monitoring Systems and Relationship to ISO 15197
Freckmann, G., Mende, J., Pleus, S., Waldenmaier, D., Baumstark, A., Jendrike, N. R. M., & Haug, C. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211001402 · Cited by 32
Self-citationAccuracy Evaluation of CONTOUR®PLUS Compared With Four Blood Glucose Monitoring Systems
Dunne, N., Viggiani, M. T., Pardo, S. A., Robinson, C., & Parkes, J. L. (2015) · Diabetes Therapy · doi:10.1007/s13300-015-0121-3 · Cited by 31
Smart nano-actuators for electrochemical sensing of Metformin in human plasma
Haq, I., García‐Cruz, Á., Masi, S. D., Cowen, T., Allcock, N., Malitesta, C., Mujahid, A., Hussain, T., Piletska, E. V., & Piletsky, S. A. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132928 · Cited by 28
Recommendations for self-monitoring in pediatric diabetes: a consensus statement by the ISPED
Diabetes Study Group of the Italian Society for Pediatric Endocrinology and Diabetology, Scaramuzza, A. E., Cherubini, V., Tumini, S., Bonfanti, R., Buono, P., Cardella, F., d’Annunzio, G., Frongia, A. P., Lombardo, F., et al. (2013) · Acta Diabetologica · doi:10.1007/s00592-013-0521-7 · Cited by 29
Almabadi, M. H., Truta, F. M., Adamu, G., Cowen, T., Tertiş, M., Drăgan, A.-M., Alanazi, K. D., Ștefan, M.-G., Piletska, E. V., Kiss, B., et al. (2023) · Electrochimica Acta · doi:10.1016/j.electacta.2023.142009 · Cited by 25
Effect of BGM Accuracy on the Clinical Performance of CGM: An In-Silico Study
Campos-Náñez, E., & Breton, M. D. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817710476 · Cited by 26
Freire, Y. A., Macêdo, G. A. D., Browne, R. A. V., Farias-Junior, L. F., Bezerra, Á. D. D. L., Fayh, A. P. T., Júnior, J. C. D. F., Boreskie, K. F., Duhamel, T. A., & Costa, E. C. (2019) · Journal of Physical Activity and Health · doi:10.1123/jpah.2018-0492 · Cited by 27
Baumstark, A., Jendrike, N., Pleus, S., Haug, C., & Freckmann, G. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0408 · Cited by 22
“Previous studies showed that there are a number of BGMS that do not fulfill these criteria; 24–28 therefore the possible insulin dosing errors are likely higher than those found in this study.”
Self-citationHasslacher, C., Kulozik, F., & Platten, I. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814522804 · Cited by 22
“9%) reached the minimum accuracy requirement if the new ISO criteria were applied.(12) In our study using a clinical setting, only 12 devices (44%) met these requirements, which is in line with Freckmann et al’s results and confirms our previous study with a smaller number of devices.”
ResultClinical impact of blood glucose monitoring accuracy: an in-silico study
Campos-Náñez, E., Fortwaengler, K., & Breton, M. D. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817710474 · Cited by 22
“In this study, we aim to quantify the clinical impact of BG monitoring system accuracy using the latest UVA/Padova simulation platform by (1) constructing models that replicate the characteristics of commercially available BG monitoring systems, (2) modeling type 1 subject behavior related to meals and self-treatment,…”
MethodFreckmann, G., Baumstark, A., Jendrike, N. R. M., Rittmeyer, D., Pleus, S., & Haug, C. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0341 · Cited by 23
Self-citationCurrent and future therapies to treat impaired awareness of hypoglycemia
Macon, E. L., DEVORE, M. H., Lin, Y. K., MUSIC, M. B., WOOTEN, M., McMullen, C. A., Woodcox, A. M., MARKSBURY, A. R., Beckner, Z., Patel, B. V., et al. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1271814 · Cited by 23
El‐Bassossy, H. M., Al-Thubiani, W. S., Elberry, A. A., Mujallid, M. I., Ghareib, S. A., Azhar, A. S., Banjar, Z. M., & Watson, M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0189074 · Cited by 22
How to engineer glucose oxidase for mediated electron transfer
Gutierrez, E. A., Wallraf, A., Balaceanu, A., Bocola, M., Davari, M. D., Meier, T., Duefel, H., & Schwaneberg, U. (2018) · Biotechnology and Bioengineering · doi:10.1002/bit.26785 · Cited by 22
“Electrochemical sensors of the second generation are most commonly used in diabetes care (Freckmann et al., 2012; Hoenes et al., 2008).”
MethodAccuracy of the CONTOUR® Blood Glucose Monitoring System
Harrison, B., Leazenby, C., & Halldorsdottir, S. S. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500425 · Cited by 24
Grunberger, G., Bailey, T. S., Camacho, P. M., EINHORN, D. F., Garber, A. J., Handelsman, Y., Harrell, R. M., Lando, H. M., Law, B., Leffert, J. D., et al. (2015) · Endocrine Practice · doi:10.4158/ep15653.cs · Cited by 22
“However, at least 6 studies evaluating the performance of blood GM devices published between 2010 and 2014 have demonstrated that only 40 to 83% met ISO 2003 standards, and only 14 to 67% met ISO 2013 standards (19-24).”
Enhancing Glycemic Control via Detection of Insulin Using Electrochemical Impedance Spectroscopy
Malkoc, A., Probst, D., Lin, C., Khanwalker, M., Beck, C., Cook, C. B., & Belle, J. T. L. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817699639 · Cited by 21
Hansen, R., Andersen, J., Vinther, A. S., Pielmeier, U., & Larsen, R. G. (2016) · International Journal of Sports Medicine · doi:10.1055/s-0042-113466 · Cited by 22
Ardilouze, A., Bouchard, P., Hivert, M., Simard, C., Allard, C., Lapointe‐Garant, M., Ménard, J., Ouellet, A., Houde, G., Pesant, M.-H., et al. (2019) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2019.02.004 · Cited by 22
Choukem, S. P., Sih, C., Nebongo, D. N., Tientcheu, P., & Kengne, A. P. (2019) · Pan African Medical Journal · doi:10.11604/pamj.2019.32.118.15553 · Cited by 26
“They used similar methods in 2012 [25] to assess 43 glucometers with the CE label, using 100 capillary samples spanning across concentrations of 50 to 400 mg/dL.”
MethodLópez-Jiménez, D., Espinosa-Chaurand, L. D., Maeda-Martínez, A. N., & Peraza-Gómez, V. (2023) · Aquaculture · doi:10.1016/j.aquaculture.2023.740283 · Cited by 20
Heinemann, L., Deiss, D., Hermanns, N., Graham, C., Kaltheuner, M., Liebl, A., & Price, D. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815575999 · Cited by 19
“” However, in case a patient uses a meter that is shown in respective evaluation studies to have an insufficient measurement quality, this might be switched to one with an adequate quality.(56) Statistics A statistical analysis plan (SAP) will be established for this study.”
MethodIncreasing awareness of hypoglycaemia in patients with Type 2 diabetes treated with oral agents
Barnett, A. H., Brice, R., Hanif, W., James, J., & Langerman, H. (2013) · Current Medical Research and Opinion · doi:10.1185/03007995.2013.834250 · Cited by 20
A Model of Self-Monitoring Blood Glucose Measurement Error
Vettoretti, M., Facchinetti, A., Sparacino, G., & Cobelli, C. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817698498 · Cited by 21
An anti-HCT-interference glucose sensor based on a fiber paper-based screen-printed carbon electrode
He, X., Chang, S. J., Settu, K., Chen, C.-J., & Liu, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.126763 · Cited by 19
Dickson, L. M., Buchmann, E., van Rensburg, C. J., & Norris, S. A. (2018) · Journal of Clinical & Translational Endocrinology · doi:10.1016/j.jcte.2018.12.003 · Cited by 20
“There are independent reports of suboptimal glucometer fulfilment of ISO recommendations post-marketing [13].”
BackgroundMethodThe financial impact of inaccurate blood glucose monitoring systems
Fortwaengler, K., Campos-Náñez, E., Parkin, C. G., & Breton, M. D. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817731423 · Cited by 17
“For nine out of the 43 assessed systems, a complete system accuracy assessment could not be performed because of a sensitivity to blood oxygen.(24) For these systems, we used the existing data (180 instead of 200 measurements) and assumed the same performance for the missing data.”
MethodFang, Z., Hu, X., Chen, Z., Xie, J., Wu, D., Yin, Y., & You, L. (2020) · Saudi Pharmaceutical Journal · doi:10.1016/j.jsps.2020.04.009 · Cited by 17
“The blood glucose (BG) of type 2 diabetes patients and animals were measured using the BG meter with test strips (Bayer, Lev-erkusen, Germany), as described in previous study (Freckmann et al. 2012).”
Monitoring Glycemia in Diabetes
Healy, S. J., & Dungan, K. M. (2014) · Medical Clinics of North America · doi:10.1016/j.mcna.2014.08.017 · Cited by 23
Sultson, H., Vainik, U., & Kreegipuu, K. (2018) · Appetite · doi:10.1016/j.appet.2018.11.031 · Cited by 19
“Glucometer Accu-Check Performa Nano that has proven to be relatively reliable among glucometers (Freckmann et al., 2012) was also used to measure blood glucose level in order to attain an additional measure of hunger.”
MethodBlood glucose monitoring techniques: recent advances, challenges and future perspectives
Gamessa, T. W., Suman, D., & Tadesse, Z. K. (2018) · International Journal of Advanced Technology and Engineering Exploration · doi:10.19101/ijatee.2018.546008 · Cited by 20
“A system accuracy of CE approved invasive blood glucose monitors was evaluated where some devices failed to meet minimum accuracy requirements of DIN EN ISO 15197:2003 and ISO 15197:2013 standards [64, 65].”
MethodBest, T., Clarke, C., Nuzum, N. D., & Teo, W. (2019) · Nutritional Neuroscience · doi:10.1080/1028415x.2019.1690288 · Cited by 18
“Chek Performa glucometer has been shown to meet the accuracy and reliability standards for glucose testing [23].”
MethodYu-Fei, W., Wei-Ping, J., Ming-Hsun, W., Miao-O, C., Ming-Chang, H., Chi-Pin, W., & Ming-Shih, L. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817705143 · Cited by 15
Huang, T.-Y., Chang, H.-W., Tsao, M.-F., Chuang, S.-M., Ni, C.-C., Sue, J.-W., Lin, H.-C., & Hsu, C.-T. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.02.023 · Cited by 15
LMI-Based Approaches for the Calibration of Continuous Glucose Measurement Sensors
Kirchsteiger, H., Zaccarian, L., Renard, É., & del Re, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2341703 · Cited by 15
“2341703 for example [3], for a performance comparison of 43 SMBG devices and [4] for a head-to-head comparison of three CGM”
BackgroundGiessmann, L. C., & Kann, P. H. (2018) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-0654-5134 · Cited by 17
Evaluation of portable blood glucose meters using canine and feline pooled blood samples
Mori, A., Oda, H., Onozawa, E., Shono, S., Takahashi, T., Yamashita, S., Fujimoto, H., & Sako, T. (2016) · Polish Journal of Veterinary Sciences · doi:10.1515/pjvs-2016-0089 · Cited by 15
“However, the ISO 15197:2013 requirements are considered strict clinical indices according to previous studies (Freckmann et al. 2012, Brito-Casillas et al. 2014, Khositseth et al. 2015).”
MethodMoreira, F. D., Mendes, G. F., Nascimento, G. D. M., Reis, C. E. G., Gallassi, A. D., & Welker, A. F. (2023) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2023.09.013 · Cited by 15
Endosperm structure and Glycemic Index of Japonica Italian rice varieties
Haxhari, F., Savorani, F., Rondanelli, M., Cantaluppi, E., Campanini, L., Magnani, E., Simonelli, C., Gavoci, G., Chiadò, A., Sozzi, M., et al. (2024) · Frontiers in Plant Science · doi:10.3389/fpls.2023.1303771 · Cited by 14
Metadata
- Authors
- Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C.
- Affiliations
- Universität Ulm (DE)
- Corresponding author
- Freckmann, Guido
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2012-09
- Volume
- 6
- Issue
- 5
- Pages
- 1060-1075
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC3570840
- OpenAlex
- W2153556745
- Cited by
- 237
- References
- 36
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 9 · 2023: 13 · 2022: 8 · 2021: 11 · 2020: 16 · 2019: 19 · 2018: 30 · 2017: 28 · 2016: 23 · 2015: 22 · 2014: 31 · 2013: 20 · 2012: 1
- FWCI
- 18.99
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- self-monitoring of blood glucose, blood glucose meters, test strips, measurement accuracy, CE marking, glucose oxidase method, hexokinase method, bias, diabetes management
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Blood Glucose, Diabetes Mellitus, Equipment and Supplies, European Union, Female, Humans, Insulin Infusion Systems, Male, Middle Aged, Oxygen, Reference Standards, Blood Glucose Self-Monitoring, Reproducibility of Results, Device Approval, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.