CoChat

Analytic Evaluation of a New Glucose Meter System in 15 Different Critical Care Settings

Open access
Mitsios, John V., Ashby, Lori A., Haverstick, Doris M., Bruns, David E., Scott, Mitchell G. · 2013 · Journal of Diabetes Science and Technology

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Background: Maintaining appropriate glycemic control in critically ill patients reduces morbidity and mortality. The use of point-of-care (POC) glucose devices is necessary to obtain rapid results at the patient's bedside. However, the devices should be thoroughly tested in the intended population before implementation. The use of POC glucose meters in critically ill patients has been questioned both in the literature and by regulatory agencies. The aim of this study was to determine if the ACCU-CHEK® Inform II system (Roche Diagnostics) POC glucose meter demonstrated the desired accuracy and precision, as defined by Clinical and Laboratory Standards Institute guideline POCT12-A3, in a large number of critically ill patients from multiple intensive care settings at two academic medical centers. Methods: A total of 1200 whole blood meter results from 600 patients were compared with central laboratory plasma values. Whole blood aliquots from venous samples were used to obtain duplicate meter results with the remaining sample being processed to obtain plasma for central laboratory testing within 5 min of meter testing. Results: A total of 1185 (98.8%) of the new meter's glucose values were within ±12.5% (±12 mg/dl for values ≥100 mg/dl) of the comparative laboratory glucose values, and 1198 (99.8%) were within ±20% (±20 mg/dl for values <100 mg/dl). Conclusions: Considering the large number of patients from numerous critical care units examined, the new glucose meter system appears to have sufficient analytic accuracy for use in critically ill patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229681300700518

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Research works printed but not linked: 1

  1. Clinical and Laboratory Standards Institute, 2013, Point-of-Care Blood Glucose Testing in Acute and Chronic Care Facilities

Cited by

See all 30

Metadata

Authors
Mitsios, J. V., Ashby, L. A., Haverstick, D. M., Bruns, D. E., & Scott, M. G.
Affiliations
  • Washington University in St. Louis (US)
  • Barnes-Jewish Hospital (US)
  • University of Virginia (US)
Corresponding author
Scott, Mitchell G.
Venue
Journal of Diabetes Science and Technology
Published
2013-09
Volume
7
Issue
5
Pages
1282-1287
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2097128370
Cited by
30
References
28
Citations by year
2025: 2 · 2023: 3 · 2021: 1 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 2 · 2014: 3 · 2013: 1
FWCI
2.63
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
Keywords
point-of-care glucose testing, glucose meter accuracy, critically ill patients, glycemic control, intensive care unit, whole blood glucose
MeSH terms
Blood Glucose, Critical Care, Humans, Hyperglycemia, Intensive Care Units, Point-of-Care Systems

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analytic Evaluation of a New Glucose Meter System in 15 Different Critical Care Settings. https://app.cochat.ai/papers/10.1177/193229681300700518
The paper
Mitsios, J. V., Ashby, L. A., Haverstick, D. M., Bruns, D. E., & Scott, M. G. (2013). Analytic Evaluation of a New Glucose Meter System in 15 Different Critical Care Settings. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681300700518

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.