Analytic Evaluation of a New Glucose Meter System in 15 Different Critical Care Settings
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Background: Maintaining appropriate glycemic control in critically ill patients reduces morbidity and mortality. The use of point-of-care (POC) glucose devices is necessary to obtain rapid results at the patient's bedside. However, the devices should be thoroughly tested in the intended population before implementation. The use of POC glucose meters in critically ill patients has been questioned both in the literature and by regulatory agencies. The aim of this study was to determine if the ACCU-CHEK® Inform II system (Roche Diagnostics) POC glucose meter demonstrated the desired accuracy and precision, as defined by Clinical and Laboratory Standards Institute guideline POCT12-A3, in a large number of critically ill patients from multiple intensive care settings at two academic medical centers. Methods: A total of 1200 whole blood meter results from 600 patients were compared with central laboratory plasma values. Whole blood aliquots from venous samples were used to obtain duplicate meter results with the remaining sample being processed to obtain plasma for central laboratory testing within 5 min of meter testing. Results: A total of 1185 (98.8%) of the new meter's glucose values were within ±12.5% (±12 mg/dl for values ≥100 mg/dl) of the comparative laboratory glucose values, and 1198 (99.8%) were within ±20% (±20 mg/dl for values <100 mg/dl). Conclusions: Considering the large number of patients from numerous critical care units examined, the new glucose meter system appears to have sufficient analytic accuracy for use in critically ill patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Meters that are designed for professional use have been shown in published studies to be accurate on samples of whole blood (129-131).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [130]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977
Standards of Medical Care in Diabetes
Power, D. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,673
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639
Basevi, V., Di Mario, S., Morciano, C., Nonino, F., & Magrini, N. (2011) · Diabetes Care · doi:10.2337/dc11-0174 · Cited by 3,055
Standards of Medical Care in Diabetes—2012
(2012) · Diabetes Care · doi:10.2337/dc12-s011 · Cited by 2,240
Capes, S. E., Hunt, D., Malmberg, K., & Gerstein, H. C. (2000) · The Lancet · doi:10.1016/s0140-6736(99)08415-9 · Cited by 2,187
Standards of Medical Care in Diabetes–2006
American Diabetes Association (2006) · Diabetes Care · doi:10.2337/diacare.29.s1.06.s4 · Cited by 1,885
Capes, S. E., Hunt, D., Malmberg, K., Pathak, P., & Gerstein, H. C. (2001) · Stroke · doi:10.1161/hs1001.096194 · Cited by 1,824
Moghissi, E. S., Korytkowski, M. T., DiNardo, M., Einhorn, D., Hellman, R., Hirsch, I. B., Inzucchi, S. E., Ismail-Beigi, F., Kirkman, M. S., & Umpierrez, G. E. (2009) · Diabetes Care · doi:10.2337/dc09-9029 · Cited by 1,444
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Self-citation
Research works printed but not linked: 1
- Clinical and Laboratory Standards Institute, 2013, Point-of-Care Blood Glucose Testing in Acute and Chronic Care Facilities
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Self-citationSacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 203
Self-citationPre-morbid glycemic control modifies the interaction between acute hypoglycemia and mortality
Egi, M., Krinsley, J. S., Maurer, P., Amin, D., Kanazawa, T., Ghandi, S., Morita, K., Bailey, M., & Bellomo, R. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4216-8 · Cited by 105
Karon, B. S., Blanshan, C. T., Deobald, G. R., & Wockenfus, A. M. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0074 · Cited by 31
Zhang, R., Isakow, W., Kollef, M. H., & Scott, M. G. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002572 · Cited by 25
Self-citation
Metadata
- Authors
- Mitsios, J. V., Ashby, L. A., Haverstick, D. M., Bruns, D. E., & Scott, M. G.
- Affiliations
- Washington University in St. Louis (US)
- Barnes-Jewish Hospital (US)
- University of Virginia (US)
- Corresponding author
- Scott, Mitchell G.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2013-09
- Volume
- 7
- Issue
- 5
- Pages
- 1282-1287
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC3876372
- OpenAlex
- W2097128370
- Semantic Scholar
- 97b4bababe217278b08348c93aaacf4ceb66cd74
- Cited by
- 30
- References
- 28
- Citations by year
- 2025: 2 · 2023: 3 · 2021: 1 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 2 · 2014: 3 · 2013: 1
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Keywords
- point-of-care glucose testing, glucose meter accuracy, critically ill patients, glycemic control, intensive care unit, whole blood glucose
- MeSH terms
- Blood Glucose, Critical Care, Humans, Hyperglycemia, Intensive Care Units, Point-of-Care Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analytic Evaluation of a New Glucose Meter System in 15 Different Critical Care Settings. https://app.cochat.ai/papers/10.1177/193229681300700518
- The paper
- Mitsios, J. V., Ashby, L. A., Haverstick, D. M., Bruns, D. E., & Scott, M. G. (2013). Analytic Evaluation of a New Glucose Meter System in 15 Different Critical Care Settings. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681300700518
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.