Dexcom G4AP: An Advanced Continuous Glucose Monitor for the Artificial Pancreas

Open access
Garcia, Arturo, Rack-Gomer, Anna Leigh, Bhavaraju, Naresh C., Hampapuram, Haripriyan, Kamath, Apurv, Peyser, Thomas, Facchinetti, Andrea, Zecchin, Chiara, Sparacino, Giovanni, Cobelli, Claudio · 2013 · Journal of Diabetes Science and Technology
Cited by 47

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Input from continuous glucose monitors (CGMs) is a critical component of artificial pancreas (AP) systems, but CGM performance issues continue to limit progress in AP research. While G4 PLATINUM has been integrated into AP systems around the world and used in many successful AP controller feasibility studies, this system was designed to address the needs of ambulatory CGM users as an adjunctive use system. Dexcom and the University of Padova have developed an advanced CGM, called G4AP, to specifically address the heightened performance requirements for future AP studies. The G4AP employs the same sensor and transmitter as the G4 PLATINUM but contains updated denoising and calibration algorithms for improved accuracy and reliability. These algorithms were applied to raw data from an existing G4 PLATINUM clinical study using a simulated prospective procedure. The results show that mean absolute relative difference (MARD) compared with venous plasma glucose was improved from 13.2% with the G4 PLATINUM to 11.7% with the G4AP. Accuracy improvements were seen over all days of sensor wear and across the plasma glucose range (40–400 mg/dl). The greatest improvements occurred in the low glucose range (40–80 mg/dl), in euglycemia (80–120 mg/dl), and on the first day of sensor use. The percentage of sensors with a MARD <15% increased from 69% to 80%. Metrics proposed by the AP research community for addressing specific AP requirements were also computed. The G4AP consistently exhibited improved sensor performance compared with the G4 PLATINUM. These improvements are expected to enable further advances in AP research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229681300700604

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 47

Metadata

Authors
Garcia, A., Rack-Gomer, A. L., Bhavaraju, N. C., Hampapuram, H., Kamath, A., Peyser, T., Facchinetti, A., Zecchin, C., Sparacino, G., & Cobelli, C.
Venue
Journal of Diabetes Science and Technology
Published
2013-11
Volume
7
Issue
6
Pages
1436-1445
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2170547493
Cited by
47
References
2
Type
conference abstract
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dexcom G4AP: An Advanced Continuous Glucose Monitor for the Artificial Pancreas. https://app.cochat.ai/papers/10.1177/193229681300700604
The paper
Garcia, A., Rack-Gomer, A. L., Bhavaraju, N. C., Hampapuram, H., Kamath, A., Peyser, T., Facchinetti, A., Zecchin, C., Sparacino, G., & Cobelli, C. (2013). Dexcom G4AP: An Advanced Continuous Glucose Monitor for the Artificial Pancreas. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681300700604

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.