Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background: Implantable biosensors for continuous glucose monitoring can greatly improve diabetes management. However, their applications are still associated with some challenges and one of these is the gradual functionality loss postimplantation as a consequence of the foreign body response (FBR). Sensor miniaturization in combination with drug-eluting biocompatible coatings is a promising strategy to enhance in vivo performance. However, limited study has been performed to understand the effect of initial trauma and implant size on foreign body reaction as well as in vivo performance of implantable glucose sensors. Methods: Different initial trauma was induced by implanting composite coated dummy sensors into rats using various sized needles and 3 different-sized dummy sensors were implanted to examine the size effect. Histological evaluation was performed to relate the inflammatory cell counts and foreign body capsule thickness with the implantation needle size and sensor size respectively. The effect of biocompatible coating on the performance of implantable glucose sensors was determined using both coated amperometric glucose sensors and microdialysis probes. Results: The results revealed that the degree of acute inflammation was mainly controlled by the extent of the initial trauma: the greater the trauma, the greater the acute inflammatory response. Implant size did not affect the acute inflammatory phase. However, the extent of chronic inflammation and fibrous encapsulation were affected by sensor size: the smaller the size the less the extent of chronic inflammation and fibrous encapsulation. Glucose sensors implanted using 14 gauge needles showed significantly lower initial in vivo response compared to those implanted using 16 gauge needles. This was not observed for sensors with dexamethasone-eluting biocompatible coatings since inflammation was suppressed. Conclusions: The results of the current study indicate that the extent of the inflammatory response post–sensor implantation varies as a function of the initial tissue trauma as well as the sensor size. Accordingly, miniaturization of implantable biosensors together with the utilization of a drug-eluting biocompatible composite coating may be a promising strategy to achieve long-term reliable continuous glucose monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“It is therefore unsurprising that the degree of implantation trauma is linked to the degree of FBR (Wang et al., 2015).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Wang et al., 2015
The cited source says what the claim attributes to it.
In the citing paper
“FBR is fundamentally tied to tissue trauma (Wang et al., 2015; Klopfleisch and Jung, 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Wang et al., 2015
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theoharides, T. C., Alysandratos, K.-D., Angelidou, A., Delivanis, D.-A., Sismanopoulos, N., Zhang, B., Asadi, S., Vasiadi, M., Weng, Z., Miniati, A., et al. (2012) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2010.12.014 · Cited by 680
Effect of acidic pH on PLGA microsphere degradation and release
Zolnik, B. S., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.05.034 · Cited by 560
Self-citationA Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390 · cited 1×
“The glucose concentration in the interstitial fluid is generally considered to be equal to the blood glucose level, although a short lag phase is reported.(27) Tissue injuries caused during the implantation process induce acute inflammation with associated edema.”
BackgroundEmerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Self-citationWard, W. K. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200504 · Cited by 325
Evaluation of in vivo–in vitro release of dexamethasone from PLGA microspheres
Zolnik, B. S., & Burgess, D. J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.004 · Cited by 286
Self-citationHickey, T., Kreutzer, D., Burgess, D. J., & Moussy, F. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00291-5 · Cited by 268
Self-citationElevated temperature accelerated release testing of PLGA microspheres
Zolnik, B. S., Leary, P. E., & Burgess, D. J. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.02.015 · Cited by 233
Self-citationConcurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis
Patil, S. D., Papadmitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.013 · Cited by 230 · cited 1×
“In addition, coatings that codeliver growth factors and dexamethasone to control FBR and promote blood vessel growth simultaneously have also been reported.(10,12) Accordingly, miniaturization of the implantable biosensor in combination with the utilization of a drug-eluting biocompatible coatings would be promising t…”
BackgroundSelf-citationImplantable enzyme amperometric biosensors
Kotanen, C. N., Moussy, F. G., Carrara, S., & Guiseppi‐Elie, A. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.03.016 · Cited by 185
Research works printed but not linked: 4
- 5. David JAS, Cunningham D. In Vivo Glucose Sensing . Hoboken, NJ: John Wiley; 2009.
- 7. Wang Y, Papadimitrakopoulos F, Burgess DJ. Polymeric 'smart' coatings to prevent foreign body response to implantable biosensors. J Control Release . 2013.
- 14. performance and the foreign body response-part I: theoretical framework. J Diabetes Sci Technol . 2011;5:632-646.
- 24. Villarreal G, Zagorski J, Wahl SM. Inflammation: Acute . Hoboken, NJ: John Wiley; 2001.
Cited by
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“It is therefore unsurprising that the degree of implantation trauma is linked to the degree of FBR (Wang et al., 2015).”
BackgroundPiech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Mayer, M., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00719 · Cited by 300
Domesticating the foreign body response: recent advances and applications
Veiseh, O., & Vegas, A. J. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.08.010 · Cited by 245
Challenges for successful implantation of biofuel cells
Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.05.011 · Cited by 224
Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review
Rodrigues, D., Barbosa, A. I., Rebelo, R., Kwon, I. K., Reis, R. L., & Correlo, V. M. (2020) · Biosensors · doi:10.3390/bios10070079 · Cited by 220
“The negative FBR of the body involves a cascade of events, including typical wound healing response, acute inflammation, chronic inflammation, and the formation of granulomatous tissue and eventually excessive fibrosis [69,70].”
BackgroundRibet, F., Stemme, G., & Roxhed, N. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0349-6 · Cited by 181
“The size of a transdermally implanted device affects the tissue trauma during insertion and the degree of inflammation over time, both of which cause an increased foreign body reaction that can be detrimental for long-termmeasurements (El-Laboudi et al. 2013;Wang et al. 2015).”
Yogev, D., Goldberg, T., Arami, A., Tejman‐Yarden, S., Winkler, T. E., & Maoz, B. M. (2023) · APL Bioengineering · doi:10.1063/5.0152290 · Cited by 166
Recent Progress and Challenges of Implantable Biodegradable Biosensors
Alam, F., Ahmed, M. A., Jalal, A. H., Siddiquee, I., Adury, R. Z., Hossain, G. M. M., & Pala, N. (2024) · Micromachines · doi:10.3390/mi15040475 · Cited by 128
Scholten, K., & Meng, E. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.02.022 · Cited by 102
In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility
Soto, R. J., Hall, J. R., Brown, M. D., Taylor, J. B., & Schoenfisch, M. H. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04251 · Cited by 95
Modulating the foreign body response of implants for diabetes treatment
Kharbikar, B. N., Chendke, G. S., & Desai, T. A. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.01.011 · Cited by 90
Joseph, J. I. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820911919 · Cited by 82
Long-term implantable glucose biosensors
Bobrowski, T., & Schuhmann, W. W. (2018) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2018.05.004 · Cited by 78
Continuous Glucose Monitoring Enabled by Fluorescent Nanodiamond Boronic Hydrogel
Zhang, J., Zheng, Y., Lee, J., Hoover, A., King, S. A., Chen, L., Zhao, J., Lin, Q., Yu, C., Zhu, L., et al. (2023) · Advanced Science · doi:10.1002/advs.202203943 · Cited by 70
Ribet, F., Stemme, G., & Roxhed, N. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.007 · Cited by 69
Jin, L., Yuan, F., Chen, C., Wu, J., Gong, R., Yuan, G., Zeng, H., Jia, P., & Chen, T. (2018) · Inflammation · doi:10.1007/s10753-018-0923-3 · Cited by 63
A Survey on Smart Wearables in the Application of Fitness
Qiu, H., Wang, X., & Xie, F. (2017) · IEEE Intl Conf on Dependable, Autonomic and Secure Computing, Intl Conf on Pervasive Intelligence and Computing, Intl Conf on Cloud and Big Data Computing, Intl Conf on Cyber Science and Technology Congress (DASC/PiCom/CBDCom/CyberSciTech) · doi:10.1109/dasc-picom-datacom-cyberscitec.2017.64 · Cited by 61
Towards a flexible electrochemical biosensor fabricated from biocompatible Bombyx mori silk
Molinnus, D., Drinic, A., Iken, H., Kröger, N., Zinser, M. J., Smeets, R., Köpf, M., Kopp, A., & Schöning, M. J. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113204 · Cited by 61
High-Strength Fiber-Reinforced Composite Hydrogel Scaffolds as Biosynthetic Tendon Graft Material
No, Y. J., Tarafder, S., Reischl, B., Ramaswamy, Y., Dunstan, C. R., Friedrich, O., Lee, C., & Zreiqat, H. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.9b01716 · Cited by 59
Malone‐Povolny, M. J., & Schoenfisch, M. H. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b19236 · Cited by 59
Bruschi, A., Donati, D. M., Choong, P., Lucarelli, E., & Wallace, G. G. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100041 · Cited by 55
Pandey, G., Chaudhari, R. D., Joshi, B., Choudhary, S., Kaur, J., & Joshi, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-41326-7 · Cited by 52
Use of Silk Proteins to Form Organic, Flexible, Degradable Biosensors for Metabolite Monitoring
Xu, M., Jiang, Y., Pradhan, S., & Yadavalli, V. K. (2019) · Frontiers in Materials · doi:10.3389/fmats.2019.00331 · Cited by 51
Developing an electrochemical sensor for the in vivo measurements of dopamine
Delmo, N., Mostafiz, B., Ross, A. E., Suni, J., & Peltola, E. (2023) · Sensors & Diagnostics · doi:10.1039/d2sd00230b · Cited by 49
In Situ Sensor Advancements for Osteoporosis Prevention, Diagnosis, and Treatment
Liu, L., & Webster, T. J. (2016) · Current Osteoporosis Reports · doi:10.1007/s11914-016-0339-7 · Cited by 47
BioMEMS for biosensors and closed-loop drug delivery
Coffel, J., & Nuxoll, E. E. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.01.030 · Cited by 46
Biointerfaced sensors for biodiagnostics
Zohar, O., Khatib, M., Omar, R., Vishinkin, R., Broza, Y. Y., & Haick, H. (2021) · View · doi:10.1002/viw.20200172 · Cited by 37
A novel semiconductor based wireless electrochemical sensing platform for chronic disease management
Mujeeb-U-Rahman, M., Nazari, M. H., & SENCAN, M. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.077 · Cited by 35
Hossain, A., Manik, M. H., Rakib, M. S., Mahmud, N., Khan, S., Ahsan, Z., Md, S. I., Hossain, N., & Akter, M. A. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100678 · Cited by 30
Pakshir, P., Younesi, F. S., Wootton, K.-A., Battiston, K. G., Whitton, G., Ilagan, B., Louka, D., Statham, M., Mackey, G., Daley, A. B., et al. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121586 · Cited by 30
Goncharov, A., Göröcs, Z. S., Pradhan, R., Ko, B. S., Ajmal, A., Rodriguez, A. F., Baum, D., Veszpremi, M., Yang, X., Pindrys, M., et al. (2024) · ACS Nano · doi:10.1021/acsnano.4c06527 · Cited by 27
Blenkuš, U., Gerós, A., Carpinteiro, C., Aguiar, P., Olsson, I. A. S., & Franco, N. H. (2022) · Animals · doi:10.3390/ani12020177 · Cited by 27
Biocompatibility of common implantable sensor materials in a tumor xenograft model
Gray, M., Meehan, J., Blair, E. O., Ward, C., Langdon, S. P., Morrison, L. R., Marland, J. R. K., Tsiamis, A., Kunkler, I. H., Murray, A., et al. (2018) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34254 · Cited by 28
Lucke, S., Walschus, U., Hoene, A., Schnabelrauch, M., Nebe, J. B., Finke, B., & Schlosser, M. (2018) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36500 · Cited by 25
Antifouling Immunomodulatory Copolymer Architectures That Inhibit the Fibrosis of Implants
Jeang, W. J., Wong, B. M., Zhao, Y., Manan, R. S., Jiang, A. L., Bose, S., Collins, E., McMullen, P., Rosenboom, J., Lathwal, S., et al. (2024) · Advanced Materials · doi:10.1002/adma.202414743 · Cited by 25
Farzin, M. A., Naghib, S. M., & Rabiee, N. (2025) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2025.118345 · Cited by 24
Beyond wearables and implantables: a scoping review of insertable medical devices
Barbone, A. S., Meftah, M., Markiewicz, K., & Dellimore, K. H. J. (2019) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ab4b32 · Cited by 24
Rigla, M., Pons, B., Rebasa, P., Luna, A., del Pozo, F. J. D., Caixàs, A., Villaplana, M., Subías, D., Bella-Cueto, M. R., & Combalía, N. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0321 · Cited by 23
Joseph, J. I., EISLER, G. J., Diaz, D., Khalf, A., Loeum, C., & Torjman, M. C. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0106 · Cited by 22
Pradhan, R., Chimene, D., Ko, B. S., Goncharov, A., Özcan, A., & McShane, M. J. (2024) · ACS Sensors · doi:10.1021/acssensors.4c01926 · Cited by 22
Beyond Encapsulation: Exploring Macrophage-Fibroblast Cross Talk in Implant-Induced Fibrosis
Sudarsanam, P. K., Alsema, E. C., Beijer, N. R. M., van Kooten, T. G., & de Boer, J. (2024) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2023.0300 · Cited by 20
Evolution of the digital biomarker ecosystem
Wright, J. M., Regele, O. B., Kourtis, L. C., Pszenny, S. M., Sirkar, R., Kovalchick, C., & Jones, G. B. (2017) · Digital Medicine · doi:10.4103/digm.digm_35_17 · Cited by 19
The role of Toll-like receptor signaling in the macrophage response to implanted materials
McKiel, L. A., Woodhouse, K. A., & Fitzpatrick, L. E. (2020) · MRS Communications · doi:10.1557/mrc.2019.154 · Cited by 18
Fabrication and in vitro performance of a dual responsive lactate and glucose biosensor
Kotanen, C. N., Karunwi, O., Alam, F., UYEHARA, C. F. T., & Guiseppi‐Elie, A. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.02.042 · Cited by 18
EISLER, G. J., Kastner, J. R., Torjman, M. C., Khalf, A., Diaz, D., Dinesen, A. R., Loeum, C., Thakur, M. L., Strasma, P. J., & Joseph, J. I. (2019) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-000881 · Cited by 18
Recent Advances in Implantable Neural Interfaces for Multimodal Electrical Neuromodulation
Wang, L., Liu, S., Zhao, W., Li, J., Zeng, H., Kang, S., Sheng, X., Wang, L., Fan, Y., & Yin, L. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303316 · Cited by 16
Qin, C., Yue, Z., Wallace, G. G., & Chen, J. (2022) · ACS Applied Bio Materials · doi:10.1021/acsabm.2c00679 · Cited by 16
An Antimicrobial and Antifibrotic Coating for Implantable Biosensors
Wareham‐Mathiassen, S., Jolly, P., Shanmugam, N. R., Jagannath, B., Prabhala, P., Zhai, Y., Özkan, A., Naziripour, A., Singh, R., Bengtsson, H. L., et al. (2025) · Biosensors · doi:10.3390/bios15030171 · Cited by 15
He, J., Renard, É., Lord, P., Cohen, D., Cem-Duranty, E., Place, J., Gu, B., Wang, X., Yenduri, G., & Burgess, D. J. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.06.005 · Cited by 15
Self-citationRibet, F., Stemme, G., & Roxhed, N. (2018) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2018.8346574 · Cited by 15
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1807.07590 · Cited by 14
Muhs, A., Bobrowski, T., Lielpētere, A., & Schuhmann, W. W. (2022) · Angewandte Chemie International Edition · doi:10.1002/anie.202211559 · Cited by 13
Chan, A., Moore, M., Grant, A. J., Lam, Y. T., Darnell, M. V., Michael, P. L., Wise, S. G., & Tan, R. P. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202301571 · Cited by 12
Advances in bioinspired polymer hydrogel systems with biomedical functionalities
Ishihara, K. (2025) · Science and Technology of Advanced Materials · doi:10.1080/14686996.2025.2469490 · Cited by 12
Intermittent actuation attenuates fibrotic behaviour of myofibroblasts
Ward, N. A., Hanley, S. A., Tarpey, R., Schreiber, L. H. J., O’Dwyer, J., Roche, E. T., Duffy, G. P., & Dolan, E. B. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.11.017 · Cited by 12
Zhang, Q., & Meyerhoff, M. E. (2021) · Electroanalysis · doi:10.1002/elan.202100174 · Cited by 12
Taylor, G. V., Shallenberger, J. R., Tint, S., Fones, A., Hamilton, H., Yu, L., Amini, S., & Hettinger, J. D. (2021) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2021.127803 · Cited by 12
Preliminary Evaluation of a Long-Term Intraperitoneal Glucose Sensor With Flushing Mechanism
Huyett, L. M., Mittal, R., Zisser, H., Luxon, E., Yee, A., Dassau, E., Doyle, F. J., & Burnett, D. R. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816640542 · Cited by 12
Chan, A., Xu, X. S., Chin, I. L., Grant, A. J., Lau, K., Hu, Y., Michael, P. L., Lam, Y. T., Wise, S. G., & Tan, R. P. (2024) · Journal of Materials Chemistry B · doi:10.1039/d4tb00705k · Cited by 11
Mechanotherapy: Modulating immune cell function in tissue regeneration and fibrosis
Ward, N. A., Prendeville, H., Wallace, E. J., Shokrani, P., Trask, L., Dillon, R., Beatty, R., Roche, E. T., Duffy, G. P., & Dolan, E. B. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.08.048 · Cited by 11
Dynamic and living devices for overcoming fibrosis of implanted biomaterials
Jackson, J. M., Testu, L., & Abramson, A. (2025) · Bioengineering & Translational Medicine · doi:10.1002/btm2.70048 · Cited by 9
Insights into development of long-acting injectable suspensions
Malavia, N., & Burgess, D. J. (2026) · Journal of Controlled Release · doi:10.1016/j.jconrel.2026.114721 · Cited by 9
Self-citationZhan, W., & Lu, F. (2017) · Cell Biology International · doi:10.1002/cbin.10731 · Cited by 8
Brain Chemistry: Neurotransmitters
Berger, S. N., & Hashemi, P. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.12682-4 · Cited by 8
Janus, K. A., Achtsnicht, S., Drinic, A., Kopp, A., Keusgen, M., & Schöning, M. J. (2023) · Applied Research · doi:10.1002/appl.202300102 · Cited by 8
Strategies for extended lifetime of implantable intraperitoneal insulin catheters
He, J., Renard, É., Lord, P., Cohen, D., Gu, B., Wang, X., Yenduri, G., & Burgess, D. J. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.11.038 · Cited by 7
Self-citationImpact of biomaterials’ physical properties on cellular and molecular responses
He, J., & Burgess, D. J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-08-102967-1.00005-0 · Cited by 6
Self-citationMarradi, M., van Griensven, M., Beijer, N. R. M., de Boer, J., & Carlier, A. (2025) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2025.07.022 · Cited by 6
Jindal, S., Bisharat, M., Khamaisi, B., Ghosal, K., Nassar‐Marjiya, E., Wu, Q., Daoud, S., Redenski, I., Srouji, S., & Farah, S. (2025) · Advanced Materials · doi:10.1002/adma.202503351 · Cited by 5
Nayak, K. K., & Bhat, N. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3449388 · Cited by 5
VCSEL-Based CMOS Integrated Optical Telemetry Link for Miniaturized Implants
Mujeeb-U-Rahman, M., & Scherer, A. (2018) · IEEE Communications Letters · doi:10.1109/lcomm.2018.2848627 · Cited by 5
Fojt, J., Průchová, E., & Hybášek, V. (2023) · Journal of Applied Electrochemistry · doi:10.1007/s10800-023-01911-1 · Cited by 6
Mena-Lapaix, J. L., Chibuko, C., Kyaw, M. H., & Prausnitz, M. R. (2025) · iScience · doi:10.1016/j.isci.2025.113741 · Cited by 4
Implantable Drug Delivery Systems
Chamgordani, N. Z. (2024) · Wiley eBooks · doi:10.1002/9781119852476.ch7 · Cited by 3
Szabo, B., Helmerich, J., Schaechtle, T., Rey, A. B. A., Rupitsch, S. J., & Stieglitz, T. (2025) · Advanced Intelligent Systems · doi:10.1002/aisy.202500121 · Cited by 4
Pencil‐Lead‐Based Quasi‐Equilibrium Glucose Biosensors
Shachneva, S., Lielpētere, A., & Schuhmann, W. W. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202400024 · Cited by 3
Laser Direct Writing of Dual-Scale 3D Structures for Cell Repelling at High Cellular Density
Păun, I. A., Călin, B. Ş., Popescu, R. C., Tanasă, E., & Moldovan, A. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23063247 · Cited by 3
Biological response to implanted intraneural electrodes
de la Oliva, N. (2018) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 3
Tian, X., Spyrou, A., Köhler, M., Kavand, H., Berggren, P., Stemme, G., & Roxhed, N. (2026) · Device · doi:10.1016/j.device.2026.101121 · Cited by 2
Cai, H., He, Y. F., Wang, C., Zhao, Y., & Yang, C. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1885022 · Cited by 2
Garhyan, P., Pratt, E. J., Klein, O., Famulla, S., Zijlstra, E., Lalonde, A., Swinney, M. R., KAZDA, C. M., & Dassau, E. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221145200 · Cited by 2
Introduction to immune responses toward medical implants
Babykutty, S., Suboj, P., & Udayan, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-99690-7.00002-9 · Cited by 2
Biomedical Devices Adopting Energy-Harvesting Schemes
Saravanan, M., Parthasarathy, E., Ajayan, J., Shanmugaraja, T., Mercy, J., Lawanya, R., & Jaishankar, B. (2023) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-031-35965-1_4 · Cited by 2
Aggas, J. R. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100676 · Cited by 2
Trocchio, L. D., Pérez-Nicoli, P., Bichon, S., Raimbault, V., Lachaud, J.-L., Gounel, S., Déjous, C., Kuhn, A., Boiziau, C., Mano, N., et al. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117970 · Cited by 2
Impaction of a continuous glucose monitoring sensor
Park, K. C., & Choi, H. J. (2021) · Archives of Plastic Surgery · doi:10.5999/aps.2021.00178 · Cited by 2
Microelectrode Biosensors for In Vivo Functional Monitoring of Biological Molecules
Marinesco, S. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-409547-2.13879-x · Cited by 2
Monahan, D. S. (2020) · Arrow@dit (Dublin Institute of Technology) · doi:10.13025/15903 · Cited by 2
Development of 3D printed enzymatic biofuel cells for powering implantable biomedical devices
Jodeiri, K. (2023) · Cited by 2
Shim, J., Heo, D. G., Oh, S., Park, J., Seo, S., You, J., Wei, Y., Kim, W., Seo, I., Kim, J., et al. (2026) · Small · doi:10.1002/smll.75269 · Cited by 1
Amireddy, K. K., Reddy, P. V. R. R., Reddy, C. N., & Reddy, P. P. (2026) · Frontiers in Sensors · doi:10.3389/fsens.2026.1968999 · Cited by 1
Scoring for Hemorrhage Severity in Traumatic Injury
Shickel, B., Balch, J. A., Aggas, J. R., Loftus, T. J., Kotanen, C. N., Rashidi, P., & Guiseppi‐Elie, A. (2022) · Biomarkers in disease · doi:10.1007/978-3-030-87302-8_58-1 · Cited by 1
Scoring for Hemorrhage Severity in Traumatic Injury
Shickel, B., Balch, J. A., Aggas, J. R., Loftus, T. J., Kotanen, C. N., Rashidi, P., & Guiseppi‐Elie, A. (2023) · Biomarkers in disease · doi:10.1007/978-3-031-07395-3_58 · Cited by 1
Magnetic microactuators for self-clearing implantable catheters
Enríquez, Á., & Lee, H. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-823294-1.00009-9 · Cited by 1
Glucose monitoring through nanoparticles: differences between optical and electrochemical analysis
Díaz, C. I. E., Tapia, M. M., Bustos, C., Coronel, M. A., Piña, G., Oñate, I., Llanganate, B., Portacio, J., Campaña, A., Burgos, M., et al. (2023) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.8364236 · Cited by 1
Ribet, F. (2020) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 1
Taylor, G. V. (2021) · Rowan Digitals Works (Rowan University) · Cited by 1
Impact of Sensing and Actuation Characteristics on Artificial Pancreas Design
Huyett, L. M. (2016) · eScholarship (California Digital Library)
Metadata
- Authors
- Wang, Y., Vaddiraju, S., Gu, B., Papadimitrakopoulos, F., & Burgess, D. J.
- Affiliations
- University of Connecticut (US)
- Biorasis (United States) (US)
- Corresponding author
- Burgess, Diane J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2015-08-25
- Volume
- 9
- Issue
- 5
- Pages
- 966-977
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC4667354
- OpenAlex
- W1830091241
- Cited by
- 107
- References
- 25
- Citations by year
- 2026: 12 · 2025: 16 · 2024: 13 · 2023: 10 · 2022: 8 · 2021: 10 · 2020: 7 · 2019: 8 · 2018: 15 · 2017: 4 · 2016: 4
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (R21-HL090458-01, R21HL090458)
- National Institute of Biomedical Imaging and Bioengineering (R43EB011886)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- foreign body reaction, implantable glucose sensor, continuous glucose monitoring, diabetes management, implant size, chronic inflammation, fibrous encapsulation, sensor miniaturization, amperometric glucose sensor, microdialysis probe
- MeSH terms
- Animals, Foreign-Body Reaction, Male, Biosensing Techniques, Rats, Sprague-Dawley, Prostheses and Implants, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.