CoChat

Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size

Open access
Wang, Yan, Vaddiraju, Santhisagar, Gu, Bing, Papadimitrakopoulos, Fotios, Burgess, Diane J. · 2015 · Journal of Diabetes Science and Technology

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Background: Implantable biosensors for continuous glucose monitoring can greatly improve diabetes management. However, their applications are still associated with some challenges and one of these is the gradual functionality loss postimplantation as a consequence of the foreign body response (FBR). Sensor miniaturization in combination with drug-eluting biocompatible coatings is a promising strategy to enhance in vivo performance. However, limited study has been performed to understand the effect of initial trauma and implant size on foreign body reaction as well as in vivo performance of implantable glucose sensors. Methods: Different initial trauma was induced by implanting composite coated dummy sensors into rats using various sized needles and 3 different-sized dummy sensors were implanted to examine the size effect. Histological evaluation was performed to relate the inflammatory cell counts and foreign body capsule thickness with the implantation needle size and sensor size respectively. The effect of biocompatible coating on the performance of implantable glucose sensors was determined using both coated amperometric glucose sensors and microdialysis probes. Results: The results revealed that the degree of acute inflammation was mainly controlled by the extent of the initial trauma: the greater the trauma, the greater the acute inflammatory response. Implant size did not affect the acute inflammatory phase. However, the extent of chronic inflammation and fibrous encapsulation were affected by sensor size: the smaller the size the less the extent of chronic inflammation and fibrous encapsulation. Glucose sensors implanted using 14 gauge needles showed significantly lower initial in vivo response compared to those implanted using 16 gauge needles. This was not observed for sensors with dexamethasone-eluting biocompatible coatings since inflammation was suppressed. Conclusions: The results of the current study indicate that the extent of the inflammatory response post–sensor implantation varies as a function of the initial tissue trauma as well as the sensor size. Accordingly, miniaturization of implantable biosensors together with the utilization of a drug-eluting biocompatible composite coating may be a promising strategy to achieve long-term reliable continuous glucose monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1932296815601869

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 4

  1. 5. David JAS, Cunningham D. In Vivo Glucose Sensing . Hoboken, NJ: John Wiley; 2009.
  2. 7. Wang Y, Papadimitrakopoulos F, Burgess DJ. Polymeric 'smart' coatings to prevent foreign body response to implantable biosensors. J Control Release . 2013.
  3. 14. performance and the foreign body response-part I: theoretical framework. J Diabetes Sci Technol . 2011;5:632-646.
  4. 24. Villarreal G, Zagorski J, Wahl SM. Inflammation: Acute . Hoboken, NJ: John Wiley; 2001.

Cited by

See all 121

Metadata

Authors
Wang, Y., Vaddiraju, S., Gu, B., Papadimitrakopoulos, F., & Burgess, D. J.
Affiliations
  • University of Connecticut (US)
  • Biorasis (United States) (US)
Corresponding author
Burgess, Diane J.
Venue
Journal of Diabetes Science and Technology
Published
2015-08-25
Volume
9
Issue
5
Pages
966-977
ISSN
1932-2968 (ISSN-L)
OpenAlex
W1830091241
Cited by
107
References
25
Citations by year
2026: 12 · 2025: 16 · 2024: 13 · 2023: 10 · 2022: 8 · 2021: 10 · 2020: 7 · 2019: 8 · 2018: 15 · 2017: 4 · 2016: 4
FWCI
3.69
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Heart, Lung, and Blood Institute (R21-HL090458-01, R21HL090458)
  • National Institute of Biomedical Imaging and Bioengineering (R43EB011886)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
foreign body reaction, implantable glucose sensor, continuous glucose monitoring, diabetes management, implant size, chronic inflammation, fibrous encapsulation, sensor miniaturization, amperometric glucose sensor, microdialysis probe
MeSH terms
Animals, Foreign-Body Reaction, Male, Biosensing Techniques, Rats, Sprague-Dawley, Prostheses and Implants, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.