Biocompatibility of an Enzyme-Based, Electrochemical Glucose Sensor for Short-Term Implantation in the Subcutis
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Continuous glucose measurements provide improved glycemic control and may prevent hypoglycemia and long-term complications of diabetes. One of the most promising techniques is the short-term implantation of electrochemical glucose sensors in subcutis. However, the inflammatory reaction to these sensors may lead to bioinstability of sensor measurements. The purpose of the present investigation was to examine factors contributing to the observed subcutaneous inflammatory reaction to an enzyme-based electrochemical glucose sensor for continuous glucose measurements. The sensor biocompatibility was assessed in vitro and in vivo. METHODS: A toxicological assessment was performed on sensor materials and leachables, and the endotoxin content of sensors was determined by a Limulus amoebocyte lysate (LAL) test. Moreover, as a consequence of permanent penetration of the skin by the sensor the role of bacterial migration to the tissue was investigated. In vivo biocompatibility was investigated through histological examination of implanted sensor membranes for 3 days in pigs. Additionally, the effect of needle size and type (normal vs. inserter needle) on tissue trauma at sensor insertion was evaluated, and the healing of subcutis was assessed histologically from 3 to 14 days after removal of sensors. RESULTS: The toxicological assessment and the LAL test showed no concerns in a 3-day implantation scenario, and bacterial migration to the subcutis could not be detected. The histological examination showed that a reduction in needle size reduced the extent of inflammation to very low levels, and that the different sensor membranes showed similar extent and type of inflammation. Additionally, the extent of subcutaneous tissue reaction after removal of sensors declined gradually over time and returned to near-normal levels after 2 weeks. CONCLUSION: The electrochemical enzyme-based glucose sensor for continuous glucose measurements in subcutis is acceptable from a biocompatibility point of view. Reducing the inserter needle in size reduces the trauma induced at sensor implantation to neglible levels. Furthermore, the tissue reaction to the sensor returns to near-normal 2 weeks after the sensor has been removed following a 3-day implantation period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The pig as a model for human wound healing
Sullivan, T. P., Eaglstein, W. H., Davis, S. C., & Mertz, P. (2001) · Wound Repair and Regeneration · doi:10.1046/j.1524-475x.2001.00066.x · Cited by 1,091 · cited 2×
“…model for human wound healing because of high degree of similarities in growth factors between human and pig studies as reviewed by Sullivan et al. 41 However, it should be emphasized that despite superiority of the pig as an animal model to investigate the biocompatibility of sensors, the in…”
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660 · cited 1×
“Several different invasive and noninvasive techniques for continous glucose measurements are available, 2–7 and one of the most promising continuous glucose monitoring systems is an implantable electrochemical sensor.”
Meyer, W., Schwarz, R., & Neurand, K. (2015) · Current Problems in Dermatology · doi:10.1159/000401274 · Cited by 454
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434 · cited 1×
“10,16,17 The sensor was based on two electrodes running as a dipole at constant voltage of 0.6 V where the reference electrode also acts as a counter electrode.”
InfluentialFinal Report on the Safety Assessment of BHT
(2002) · International Journal of Toxicology · doi:10.1080/10915810290096513 · Cited by 243
In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring
Pickup, J., McCartney, L., Rolinski, O., & Birch, D. (1999) · BMJ · doi:10.1136/bmj.319.7220.1289 · Cited by 66
Cited by
Electrochemical Sensors for Clinic Analysis
Wang, Y., Xu, H., Zhang, J., & Li, G. (2008) · Sensors · doi:10.3390/s8042043 · Cited by 398
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Metadata
- Authors
- Kvist, P. H., Iburg, T., Aalbaek, B., Gerstenberg, M., Schoier, C., Kaastrup, P., Buch-Rasmussen, T., Hasselager, E., & Jensen, H. E.
- Venue
- Diabetes Technology & Therapeutics
- Publisher
- SAGE Publications
- Published
- 2006-10
- Volume
- 8
- Issue
- 5
- Pages
- 546-559
- ISSN
- 1520-9156 (ISSN-L)
- 1557-8593
- OpenAlex
- W1993174623
- Cited by
- 38
- References
- 6
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility of an Enzyme-Based, Electrochemical Glucose Sensor for Short-Term Implantation in the Subcutis. https://app.cochat.ai/papers/10.1089/dia.2006.8.546
- The paper
- Kvist, P. H., Iburg, T., Aalbaek, B., Gerstenberg, M., Schoier, C., Kaastrup, P., Buch-Rasmussen, T., Hasselager, E., & Jensen, H. E. (2006). Biocompatibility of an Enzyme-Based, Electrochemical Glucose Sensor for Short-Term Implantation in the Subcutis. Diabetes Technology & Therapeutics. https://doi.org/10.1089/dia.2006.8.546
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.