CoChat

CGM Versus FGM; or, Continuous Glucose Monitoring Is Not Flash Glucose Monitoring

Open access
Heinemann, Lutz, Freckmann, Guido · 2015 · Journal of Diabetes Science and Technology
Cited by 126

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

It remains to be seen as to what share of the market FGM will achieve if the manufacturer can supply any amount desired.Will a significant portion of the glucose monitoring market then be taken over by FGM? The availability of FGM as anew option for glucose monitoring can basically be evaluated positively and it does indeed clearly show the benefit of“more information” on the glucose trend. The relatively low price for glucose monitoring using FGM and the unusual market introduction (not first via the National Association of Statutory Health Insurance Funds, as was the case with CGM) have given increased attention to the use of more glucose information. It will likely take a certain amount of time before other providers are able to bring different FGM systems to the market.The option of coupling a CGM system with an insulin pump offers the perspective of an automated insulin application,that is, a closed-loop system. Such systems are currently being tested under everyday conditions, although it is not possible to predict when they will actually reach the market.There are, however, such couplings where algorithms are responsible for shutting off insulin delivery when the glucose concentration reaches a defined level or if it will be reached in the foreseeable future. This significantly helps prevent hypoglycemia. These options are only available with CGM. The aim of this commentary is to present the differences between CGM and FGM, including the advantages and disadvantages of both approaches. We see significant benefits in both options based on the different positioning of the approaches and the different user groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1932296815603528

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 126

Metadata

Authors
Heinemann, L., & Freckmann, G.
Venue
Journal of Diabetes Science and Technology
Published
2015-09-01
Volume
9
Issue
5
Pages
947-950
ISSN
1932-2968 (ISSN-L)
OpenAlex
W1867710651
Cited by
126
References
4
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CGM Versus FGM; or, Continuous Glucose Monitoring Is Not Flash Glucose Monitoring. https://app.cochat.ai/papers/10.1177/1932296815603528
The paper
Heinemann, L., & Freckmann, G. (2015). CGM Versus FGM; or, Continuous Glucose Monitoring Is Not Flash Glucose Monitoring. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296815603528

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.