Psychosocial Aspects of Continuous Glucose Monitoring: Connecting to the Patients’ Experience
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Continuous glucose monitoring (CGM) systems provide people with diabetes with valuable real-time information on glucose trajectories and trends, thus offering opportunities for improving diabetes self-management. Ample evidence from clinical trials underscores CGM effectiveness for biomedical outcomes including HbA1C and hypoglycemia. However, interindividual variability in CGM uptake seems to be substantial: Neither do all individuals with diabetes adopt CGM readily in their diabetes self-management, nor do all of them benefit from CGM. In this article, we focus on CGM effects on quality of life and the potential role of psychosocial patient characteristics for determining the uptake and outcomes of CGM. After providing a brief overview on existing evidence on psychosocial factors in CGM use, gaps in existing research are identified and directions for future research are proposed that could answer key research questions and offer guidance for clinical diabetes care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U.S. Department of Health and Human Services FDA Center for Drug Evaluation and Research, U.S. Department of Health and Human Services FDA Center for Biologics Evaluation and Research, & U.S. Department of Health and Human Services FDA Center for Devices and Radiological Health (2006) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-4-79 · Cited by 2,856
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541 · cited 1×
“In terms of biomedical outcomes, CGM was found to be effective only when people with diabetes used CGM intensively, in a continuous manner and in a day-to-day fashion.(8,9) Surprisingly, even in when study participants were supplied with CGM devices for free and without additional costs for the patients (like in the J…”
Backgroundthe SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Ly, T. T., Nicholas, J. A., Retterath, A., Lim, E. M., Davis, E. A., & Jones, T. W. (2013) · JAMA · doi:10.1001/jama.2013.277818 · Cited by 411 · cited 1×
“In addition to stand-alone CGM systems, integrated systems that combine insulin pumps for insulin delivery with CGM and allow for an automatic suspension of insulin delivery in case of impeding hypoglycemia, offer new therapeutic options and were shown to be effective in terms of avoiding or reducing nocturnal hypogly…”
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Barnard, K. D., Wysocki, T., Allen, J. M., Elleri, D., Thabit, H., Leelarathna, L., Gulati, A., Nodale, M., Dunger, D. B., Tinati, T., et al. (2014) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2014-000025 · Cited by 159
Self-citation
Cited by
Natale, P., Chen, S., Chow, C. K., Cheung, N. W., Martinez‐Martin, D., Caillaud, C., Scholes‐Robertson, N., Kelly, A., Craig, J. C., Strippoli, G., et al. (2023) · Journal of Diabetes · doi:10.1111/1753-0407.13454 · Cited by 63
Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes
Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D. (2023) · Endocrine Connections · doi:10.1530/ec-23-0085 · Cited by 22
Mendez, C., Kaykayoglu, C. A., Bähler, T., Künzler, J., Lizoain, A., Rothenbühler, M., Schmidt, M. H., Laimer, M., & Witthauer, L. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251319800 · Cited by 10
Metadata
- Authors
- Kubiak, T., Mann, C. G., Barnard, K. C., & Heinemann, L.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2016-05-27
- Volume
- 10
- Issue
- 4
- Pages
- 859-863
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2407489406
- Cited by
- 49
- References
- 6
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Psychosocial Aspects of Continuous Glucose Monitoring: Connecting to the Patients’ Experience. https://app.cochat.ai/papers/10.1177/1932296816651450
- The paper
- Kubiak, T., Mann, C. G., Barnard, K. C., & Heinemann, L. (2016). Psychosocial Aspects of Continuous Glucose Monitoring: Connecting to the Patients’ Experience. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296816651450
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.