CoChat

Accuracy of a Point-of-Care Hemoglobin A1c Assay

Open access
Nathan, David M., Griffin, Amanda, Perez, Francesca M., Basque, Erica, Do, Lily, Steiner, Barbara · 2019 · Journal of Diabetes Science and Technology

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

Point-of-care test (POCT) HbA1c assays provide rapidly available results for clinical decision-making. Accuracy and precision must be established. Venous blood samples from 300 patients were assayed for HbA1c by a laboratory technician (“laboratory assessment”) with the POCT Alere Afinion™ assay and a laboratory (Premier Affinity TM ) assay. POCT results from 402 patients’ fingerstick samples assayed by nine nontechnician staff (“clinical assessment”) were compared with the laboratory assay. The laboratory assessment showed tight correlation ( r 2 = .977, P < .001) between the assays. Mean absolute and relative differences were 0.01 percentage points and 2.1%, respectively. CVs for the POCT and laboratory assays were <2% and <1%, respectively. The clinical assessment also showed a tight correlation between the assays ( r 2 = .978, P < .001), with mean absolute and relative differences of 0.2 percentage points and 3.41%, respectively. CV for the POCT assay was <2%. The POCT performed acceptably compared to the laboratory assay under realistic clinical conditions.

Overview

Integrity signals

Registry

Crossref · 10.1177/1932296819836101

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 26 references

Research works printed but not linked: 2

  1. Diabetes Control and Complications Trial Research Group, 1993, N Engl J Med, 329, 978
  2. Little RR, 2001, Clin Chem, 47, 1985

Cited by

See all 29

Metadata

Authors
Nathan, D. M., Griffin, A., Perez, F. M., Basque, E., Do, L., & Steiner, B.
Affiliations
  • Harvard University (US)
  • Massachusetts General Hospital (US)
  • Ponce Health Sciences University (PR)
  • Eastern Virginia Medical School (US)
Corresponding author
Nathan, David M.
Venue
Journal of Diabetes Science and Technology
Published
2019-04-03
Volume
13
Issue
6
Pages
1149-1153
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2934681203
Cited by
26
References
26
Citations by year
2026: 1 · 2025: 3 · 2024: 7 · 2023: 3 · 2022: 5 · 2021: 4 · 2020: 1 · 2019: 2
FWCI
2.06
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
alere (None)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Advanced Glycation End Products research
Keywords
point-of-care testing, HbA1c, fingerstick blood, venous blood, assay accuracy, assay precision, diabetes monitoring
MeSH terms
Point-of-Care Testing, Hematologic Tests, Glycated Hemoglobin, Humans, Sensitivity and Specificity, Point-of-Care Systems

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of a Point-of-Care Hemoglobin A1c Assay. https://app.cochat.ai/papers/10.1177/1932296819836101
The paper
Nathan, D. M., Griffin, A., Perez, F. M., Basque, E., Do, L., & Steiner, B. (2019). Accuracy of a Point-of-Care Hemoglobin A1c Assay. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296819836101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.