Clinical Recommendations for the Use of the Ambulatory Glucose Profile in Diabetes Care
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Background: The ambulatory glucose profile (AGP) uses the wealth of data that are generated by continuous glucose monitoring, including flash glucose monitoring technologies, to provide a visual representation of glucose levels over a typical standard day of usually the most recent two weeks for a person with diabetes and helps to identify patterns and trends in glucose control. The AGP allows certain patterns of glucose levels to be identified and analyzed, such that treatment adjustments can be made, and new individual treatment goals can be defined. This helps to ensure increased treatment satisfaction and adherence, quality of life, and an improvement in metabolic management for people with diabetes. Objective: To date, a range of approaches exists for interpreting the information contained in an AGP, with different priorities given to identifying and targeting patterns of hypoglycemia and the degree of variability and stability underlying the glucose levels. The objective of the present recommendation is to describe the steps for assessing an AGP in detail and to illustrate these steps using visual examples. Conclusion: This paper describes the consensus recommendations from a group of German expert diabetologists on the necessary steps for assessing an AGP in a structured and detailed way and to explain these steps using practical clinical examples.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“To make these metrics actionable, standardized reports with visual summaries have been implemented (33) and help individuals with diabetes and health care professionals interpret the data to guide treatment decisions (27,30).”
From 6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026. (2026) · cites this paper as [30]
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237 · cited 2×
“The expert group currently recommends a target for TIR of ≥70% for people with type 1 diabetes of all ages and for people with type 2 diabetes, which is in concordance with the newly published recommendation of the International Consensus on Time in Range.20 This target should be considered as a minimum requirement, s…”
ResultAnalysis of serial measurements in medical research.
Matthews, J. N., Altman, D. G., Campbell, M. J., & Royston, P. (1990) · BMJ · doi:10.1136/bmj.300.6719.230 · Cited by 3,136 · cited 1×
“trapezoidal rule.(2,35) This value is dependent on the peak in the median values and on the glucose stability.”
BackgroundInternational consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · cited 5×
“At least 70% of sensor data should be captured during this period, provided that data gaps are not concentrated within a certain time period.(12) In the case of extensive gaps in the data at certain times of the day (for example, due to longer intervals between scans or transmitter dysfunction), the data can only be e…”
BackgroundMethodInfluentialState of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907 · cited 1×
“A possible correlation between HbA1c and TIR has been investigated in initial studies of type 1 diabetes.(18,19) Although the correlation between TIR and HbA1c is moderate, suggestions for TIR goals can be derived from HbA1c values.”
Background6. Glycemic Targets: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s006 · Cited by 655
International Hypoglycaemia Study Group (2017) · Diabetes Care · doi:10.2337/dc16-2215 · Cited by 608
Long-term Glycemic Variability and Risk of Adverse Outcomes: A Systematic Review and Meta-analysis
Gorst, C., Kwok, C. S., Aslam, S., Buchan, I., Kontopantelis, E., Myint, P. K., Heatlie, G., Loke, Y., Rutter, M. K., & Mamas, M. A. (2015) · Diabetes Care · doi:10.2337/dc15-1188 · Cited by 530
Lu, J., Ma, X., Zhou, J., Zhang, L., Mo, Y., Ying, L., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1131 · Cited by 517 · cited 1×
“There is evidence of an association between the TIR and clinical trial outcomes.(13,16,17,36,37) However, the evidence associating TIR with diabetes outcomes is still limited, meaning that additional reports on clinical experience with this measure of glycemic control will be important for verifying these recommendati…”
BackgroundThe relationships between time in range, hyperglycemia metrics, and HbA1c
Beck, R. W., Bergenstal, R. M., Cheng, P., Kollman, C., Carlson, A. L., Johnson, M. L., & Rodbard, D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818822496 · Cited by 479 · cited 1×
“There is evidence of an association between the TIR and clinical trial outcomes.(13,16,17,36,37) However, the evidence associating TIR with diabetes outcomes is still limited, meaning that additional reports on clinical experience with this measure of glycemic control will be important for verifying these recommendati…”
BackgroundThe relationship of hemoglobin A1C to time-in-range in patients with diabetes
Vigersky, R. A., & McMahon, C. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0310 · Cited by 464 · cited 1×
“A possible correlation between HbA1c and TIR has been investigated in initial studies of type 1 diabetes.(18,19) Although the correlation between TIR and HbA1c is moderate, suggestions for TIR goals can be derived from HbA1c values.”
BackgroundAgiostratidou, G., Anhalt, H., Ball, D., Blonde, L., Gourgari, E., Harriman, K. N., Kowalski, A. J., Madden, P., McAuliffe-Fogarty, A. H., McElwee-Malloy, M., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1624 · Cited by 397
Toward Defining the Threshold Between Low and High Glucose Variability in Diabetes
Monnier, L., Colette, C., Wojtusciszyn, A., Dejager, S., Renard, E., Molinari, N., & Owens, D. R. (2017) · Diabetes Care · doi:10.2337/dc16-1769 · Cited by 390 · cited 3×
“0 mmol/L) rarely occur (Figure 4).(32,33) A comparison of the glucose profiles for a metabolically healthy person (Figure 4) and those of a person with diabetes (Figure 2) illustrate and emphasize the high glucose variability seen in people with diabetes.”
BackgroundThe International Hypoglycaemia Study Group (2017) · Diabetologia · doi:10.1007/s00125-016-4146-6 · Cited by 360
Optimal Sampling Duration for Continuous Glucose Monitoring to Determine Long-Term Glycemic Control
Riddlesworth, T. D., Beck, R. W., Gal, R. L., Connor, C. G., Bergenstal, R. M., Lee, S., & Willi, S. M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0455 · Cited by 266 · cited 3×
“diabetes that is sufficient to generate a reliable profile for identification of patterns.(8) A 14-day AGP has been shown to accurately predict the anticipated glucose control profile for up to 30 days under typical everyday conditions.”
BackgroundMethodMonnier, L., & Colette, C. (2008) · Diabetes Care · doi:10.2337/dc08-s241 · Cited by 263
Glucose Variability: Where It Is Important and How to Measure It
DeVries, J. H. (2013) · Diabetes · doi:10.2337/db12-1610 · Cited by 235
Mazze, R. S., Strock, E., Wesley, D., Borgman, S., Morgan, B., Bergenstal, R., & Cuddihy, R. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0293 · Cited by 182 · cited 4×
“trapezoidal rule.(2,35) This value is dependent on the peak in the median values and on the glucose stability.”
BackgroundMethodInfluentialBergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700234 · Cited by 166 · cited 3×
“Time in range can be shown both as a percentage and also as the number of hours that the measured glucose values are in the target range.(3) A number of protocols have been suggested in recent years to optimize analysis of the AGP (see Table 1).”
BackgroundThe importance of hypoglycemia in diabetic patients
Shafiee, G., Mohajeri-Tehrani, M., Pajouhi, M., & Larijani, B. (2012) · Journal of Diabetes & Metabolic Disorders · doi:10.1186/2251-6581-11-17 · Cited by 163 · cited 1×
“A fundamental task of adjusting treatment is to avoid hypoglycemia(21) and this is one of the biggest challenges in diabetes management.(22) Even slight hypoglycemia can be responsible for increased glucose instability (endogenous glucose release/exogenous carbohydrate delivery).”
BackgroundImproving the clinical value and utility of CGM systems: issues and recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetologia · doi:10.1007/s00125-017-4463-4 · Cited by 149
Ambulatory Glucose Profile: Representation of Verified Self-Monitored Blood Glucose Data
Mazze, R. S., Lucido, D., Langer, O., Hartmann, K., & Rodbard, D. (1987) · Diabetes Care · doi:10.2337/diacare.10.1.111 · Cited by 144 · cited 2×
“The AGP was originally developed by Mazze et al to plot the glucose data measured by patient self-monitoring of blood glucose (SMBG).(1) With the arrival of real-time continuous glucose monitoring (rtCGM) and intermittently scanned CGM (isCGM), also called flash glucose monitoring,(7) the AGP method was accordingly ad…”
MethodImproving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
Gandhi, G. Y., Kovalaske, M., Kudva, Y., Walsh, K., Elamin, M. B., Beers, M., Coyle, C., Goalen, M., Murad, M. S., Erwin, P. J., et al. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500419 · Cited by 134
Sartore, G., Chilelli, N. C., Burlina, S., Stefano, P. D., Piarulli, F., Fedele, D., Mosca, A., & Lapolla, A. (2012) · Acta Diabetologica · doi:10.1007/s00592-012-0391-4 · Cited by 90
Association of time in blood glucose range with outcomes following cardiac surgery
Omar, A. S., Salama, A., Allam, M., Elgohary, Y., Mohammed, S., Tuli, A. K., & Singh, R. (2015) · BMC Anesthesiology · doi:10.1186/1471-2253-15-14 · Cited by 78
Rickels, M. R., Peleckis, A. J., Markmann, E., Dalton-Bakes, C., Kong, S. M., Teff, K. L., & Naji, A. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-1649 · Cited by 60 · cited 1×
“There is evidence of an association between the TIR and clinical trial outcomes.(13,16,17,36,37) However, the evidence associating TIR with diabetes outcomes is still limited, meaning that additional reports on clinical experience with this measure of glycemic control will be important for verifying these recommendati…”
BackgroundVariation of fasting plasma glucose: A predictor of mortality in patients with type 2 diabetes
Lin, C.-C., Li, C.-I., Yang, S.-Y., Liu, C.-S., Chen, C.-C., Fuh, M. M.-T., Chen, W., & Li, T.-C. (2012) · The American Journal of Medicine · doi:10.1016/j.amjmed.2011.07.027 · Cited by 59
Wan, E. Y. F., Fung, C. S. C., Fong, D., & Lam, C. L. K. (2016) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2016.05.024 · Cited by 55
Trajectories of fasting plasma glucose variability and mortality in type 2 diabetes
Lee, C.-L., Sheu, W. H., Lee, I., Lin, S., Liang, W., Wang, J., & Li, Y. (2017) · Diabetes & Metabolism · doi:10.1016/j.diabet.2017.09.001 · Cited by 54
Distiller, L. A., Cranston, I., & Mazze, R. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816648165 · Cited by 45
Bonke, F. C., Donnachie, E., Schneider, A., & Mehring, M. (2015) · Diabetologia · doi:10.1007/s00125-015-3797-z · Cited by 38
Consensus recommendations for the use of Ambulatory Glucose Profile in clinical practice
Matthaei, S., DeAlaiz, R. A., Bosi, E., Evans, M., Geelhoed-Duijvestijn, N., & Joubert, M. (2014) · British Journal of Diabetes · doi:10.15277/bjdvd.2014.046 · Cited by 38 · cited 2×
“Therefore, an essential component of any AGP evaluation is to assess the variability in glucose values.(2,5,6) Glucose fluctuations within a day (intraday) and from one day to another (interday) must both be taken into account here.”
BackgroundWightman, S., Sainsbury, C. A. R., & Jones, G. C. (2018) · Diabetes Obesity and Metabolism · doi:10.1111/dom.13193 · Cited by 36
Assessing the value of the Ambulatory Glucose Profile in clinical practice
Matthaei, S. (2014) · British Journal of Diabetes · doi:10.15277/bjdvd.2014.045 · Cited by 27 · cited 1×
“For example, if the AGP shows patterns in which the IQR reaches the hypoglycemic range, then adjusting the insulin dose before this time point can be recommended.(4) What must be noted is that irregular routines and unplanned meals can also lead to a change in the IQR.”
BackgroundAmbulatory glucose profile (AGP): utility in UK clinical practice
Evans, M. L., CRANSTON, I. C., & Bailey, C. J. (2017) · British Journal of Diabetes · doi:10.15277/bjd.2017.121 · Cited by 19 · cited 1×
“In the AGP, glucose levels over several days or weeks are graphically displayed in the context of a typical 24-hour day.(10) This reflects the changes in glucose levels and displays the actual variability and stability over the selected period.”
BackgroundPraxisbezogene Empfehlungen zum Ambulanten Glukoseprofil
Kroeger, J., Reichel, A., Siegmund, T., & Ziegler, R. (2018) · Diabetologie und Stoffwechsel · doi:10.1055/a-0576-6497 · Cited by 11 · cited 1×
“These recommendations were previously documented in a German-language publication.(11)”
BackgroundSelf-citationCharacterization of Glucose Metabolism
Mazze, R. S., APRN-BC, F. E. S. S., Bergenstal, R. M., Criego, A. B., Cuddihy, R. M., Langer, O., Simonson, G. D., & Powers, M. A. (2011) · Wiley eBooks · doi:10.1002/9781119950424.ch3 · Cited by 2
Research works printed but not linked: 2
- Siegmund T, 2015, Diabetes Stoffwechsel und Herz, 24, 115
- Marks V, Hypoglycemia, 1987, 19
Cited by
6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
“1), are recommended (34) and may help the patient and the provider better interpret the data to guide treatment decisions (23,26).”
Background6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
“better interpret the data to guide treatment decisions (16,19).”
BackgroundContinuous glucose monitoring and metrics for clinical trials: an international consensus statement
Battelino, T., Alexander, C. M., Amiel, S. A., Arreaza-Rubin, G., Beck, R. W., Bergenstal, R. M., Buckingham, B. A., Carroll, J., Ceriello, A., Chow, E., et al. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(22)00319-9 · Cited by 831
6. Glycemic Targets: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684
6. Glycemic Goals and Hypoglycemia: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s006 · Cited by 486
Metadata
- Authors
- Kröger, J., Reichel, A., Siegmund, T., & Ziegler, R.
- Affiliations
- Centre for Diabetology, Hamburg Bergedorf, Germany
- University Hospital Carl Gustav Carus (DE)
- TUM Klinikum (DE)
- Diabetes Clinic for Children and Adolescents, Munster, Germany
- Corresponding author
- Kröger, Jens
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2019-11-13
- Volume
- 14
- Issue
- 3
- Pages
- 586-594
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC7576939
- OpenAlex
- W2983510380
- Cited by
- 51
- References
- 37
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 6 · 2023: 13 · 2022: 12 · 2021: 4 · 2020: 4
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- abbott diabetes care
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- ambulatory glucose profile, continuous glucose monitoring, flash glucose monitoring, diabetes management, glycemic variability, treatment goal setting
- MeSH terms
- Glycemic Control, Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Humans, Hypoglycemic Agents, Predictive Value of Tests, Blood Glucose Self-Monitoring, Reproducibility of Results, Biomarkers, Treatment Outcome, Evidence-Based Medicine, Consensus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.