Five-Year Cost-Effectiveness Modeling of Primary Care-Based, Nonmydriatic Automated Retinal Image Analysis Screening Among Low-Income Patients With Diabetes
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background: Artificial intelligence-based technology systems offer an alternative solution for diabetic retinopathy (DR) screening compared with standard, in-office dilated eye examinations. We performed a cost-effectiveness analysis of Automated Retinal Image Analysis System (ARIAS)-based DR screening in a primary care medicine clinic that serves a low-income patient population. Methods: A model-based, cost-effectiveness analysis of two DR screening systems was created utilizing data from a recent study comparing adherence rates to follow-up eye care among adults ages 18 or older with a clinical diagnosis of diabetes. In the study, the patients were prescreened with an ARIAS-based, nonmydriatic (undilated), point-of-care tool in the primary care setting and were compared with patients with diabetes who were referred for dilated retinal screening without prescreening, as is the current standard of care. Using a Markov model with microsimulation resulting in a total of 600 000 simulated patient experiences, we calculated the incremental cost-utility ratio (ICUR) of the two screening approaches, with regard to five-year cost-effectiveness of DR screening and treatment of vision-threatening DR. Results: At five years, ARIAS-based screening showed similar utility as the standard of care screening systems. However, ARIAS reduced costs by 23.3%, with an ICUR of $258 721.81 comparing the current practice to ARIAS. Conclusions: Primary care-based ARIAS DR screening is cost-effective when compared with standard of care screening methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Prevalence of Diabetic Retinopathy in the United States, 2005-2008
Zhang, X., Saaddine, J. B., Chou, C.-F., Cotch, M. F., Cheng, Y. J., Geiss, L. S., Gregg, E. W., Albright, A. L., Klein, B. E. K., & Klein, R. (2010) · JAMA · doi:10.1001/jama.2010.1111 · Cited by 1,196
Guidelines on Diabetic Eye Care
Wong, T. Y., Sun, J., Kawasaki, R., Ruamviboonsuk, P., Gupta, N., Lansingh, V. C., Maia, M., Mathenge, W., Moreker, S., Muqit, M. M. K., et al. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.04.007 · Cited by 839
Elman, M. J., Ayala, A., Bressler, N. M., Browning, D., Flaxel, C. J., Glassman, A. R., Jampol, L. M., & Stone, T. W. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2014.08.047 · Cited by 562
Prevalence of and Risk Factors for Diabetic Macular Edema in the United States
Varma, R., Bressler, N. M., Doan, Q. V., Gleeson, M., Danese, M., Bower, J. K., Selvin, E., Dolan, C., Fine, J., Colman, S., et al. (2014) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.2854 · Cited by 423
Gross, J. G., Glassman, A. R., Liu, D., Sun, J. K., Antoszyk, A. N., Baker, C. W., Bressler, N. M., Elman, M. J., Ferris, F. L., Gardner, T. W., et al. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.3255 · Cited by 404
Automated Diabetic Retinopathy Image Assessment Software
Tufail, A., Rudisill, C., Egan, C., Kapetanakis, V. V., Salas-Vega, S., Owen, C. G., Lee, A., Louw, V., Anderson, J., Liew, G., et al. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.11.014 · Cited by 283
Bressler, S. B., Glassman, A. R., Almukhtar, T., Bressler, N. M., Ferris, F. L., Googe, J. M., Gupta, S. K., Jampol, L. M., Melia, M., & Wells, J. A. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.12.025 · Cited by 139
Liu, J., Gibson, E., Ramchal, S., Shankar, V., Piggott, K., Sychev, Y., Li, A. S., Rao, P. K., Margolis, T. P., Fondahn, E., et al. (2021) · Ophthalmology Retina · doi:10.1016/j.oret.2020.06.016 · Cited by 88
Self-citation
Research works printed but not linked: 28
- 10.1080/09286586.2016.1193618 · DOI · Paper page
- 10.1016/S0002-9394(02)01593-3 · doi:10.1016/s0002-9394(02)01593-3
- 10.1001/jamainternmed.2017.0204 · DOI · Paper page
- 10.1111/aos.12481 · DOI
- 10.1016/j.compbiomed.2016.01.027 · doi:10.1016/j.compbiomed.2016.01.027
- 10.1016/j.oret.2018.10.014 · DOI · Paper page
- 10.1177/1932296816628546 · DOI · Paper page
- 10.1016/j.ophtha.2012.01.049 · DOI
- 10.1001/jamaophthalmol.2016.1669 · DOI · Paper page
- 10.1001/jamaophthalmol.2017.0837 · DOI · Paper page
- 10.1001/jama.2015.15217 · DOI · Paper page
- 10.1016/j.ophtha.2010.02.031 · DOI · Paper page
- 10.1016/j.ophtha.2010.12.033 · DOI · Paper page
- 10.2337/dc09-0615 · DOI · Paper page
- 10.1016/j.ophtha.2012.08.022 · DOI · Paper page
- 10.2147/OPTH.S117958 · DOI
- 10.1167/iovs.12-11549 · doi:10.1167/iovs.12-11549
- 10.1016/S0161-6420(01)00764-3 · DOI
- 10.7326/0003-4819-113-2-147 · DOI · Paper page
- 10.1016/S0039-6257(02)00457-5 · DOI · Paper page
- 10.1016/j.ophtha.2016.02.022 · DOI · Paper page
- 10.1001/jama.2019.5790 · DOI · Paper page
- 10.1089/tmj.2005.11.641 · DOI · Paper page
- 10.1001/jamaophthalmol.2020.3237 · DOI
- Kuo J, 2020, Mo Med, 117, 258
- 10.1056/NEJMoa1917130 · DOI · Paper page
- 10.1097/ICU.0000000000000552 · DOI
- 10.1016/j.survophthal.2019.02.003 · DOI
Cited by
Voets, M. M., Veltman, J., Slump, C. H., Siesling, S., & Koffijberg, H. (2022) · Value in Health · doi:10.1016/j.jval.2021.11.1362 · Cited by 105
“20,21,28,29 , 27-30 , 32”
BackgroundMethodCost-effectiveness of artificial intelligence screening for diabetic retinopathy in rural China
Huang, X.-M., Yang, B.-F., Zheng, W.-L., Liu, Q., Xiao, F., Ouyang, P.-W., Li, M.-J., Li, X.-Y., Meng, J., Zhang, T.-T., et al. (2022) · BMC Health Services Research · doi:10.1186/s12913-022-07655-6 · Cited by 89
“It costs less to grade a fundus image by AI screening relative to oph-thalmologist screening ($1.447 per patient versus $3.213 Our results consist with the findings in previous literatures although the research settings are different [39–42].”
BackgroundResultInfluentialKHAN, Z., GAIDHANE, A. M., SINGH, M., GANESAN, S., KAUR, M., SHARMA, G. C., RANI, P., SHARMA, R., THAPLIYAL, S., KUSHWAHA, M., et al. (2025) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2025.02.022 · Cited by 49
Patel, D., Ananthakrishnan, A., Lin, T., Channa, R., Liu, T. Y. A., & Wolf, R. M. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11237120 · Cited by 43
“Adherence to regular DR examinations has been reported to be as low as 11% in adults [79], but implementation of universal screening programs, teleretinal screening programs, and more recently, AI screening programs, have shown success in improving screening rates and thereby reducing the risk of blindness from DR [80…”
BackgroundTeng, C. W., Patel, S. D., Barkmeier, A. J., Liu, T. Y. A., Myung, D., Henderer, J., Liu, J., Hansen, E., & Al-Aswad, L. A. (2026) · Ophthalmology Science · doi:10.1016/j.xops.2025.100935 · Cited by 36
“42,48,67 Among the 3 commercially available US FDA — cleared systems, both LumineticsCore and EyeArt have been implemented outside of trial conditions for 3 to 5 years with adequate levels of imageability and accuracy reported.”
InfluentialSelf-citation
Metadata
- Authors
- Fuller, S. D., Hu, J., Liu, J. C., Gibson, E., Gregory, M., Kuo, J., & Rajagopal, R.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2020-10-30
- Volume
- 16
- Issue
- 2
- Pages
- 415-427
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W3097024488
- Cited by
- 55
- References
- 9
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Five-Year Cost-Effectiveness Modeling of Primary Care-Based, Nonmydriatic Automated Retinal Image Analysis Screening Among Low-Income Patients With Diabetes. https://app.cochat.ai/papers/10.1177/1932296820967011
- The paper
- Fuller, S. D., Hu, J., Liu, J. C., Gibson, E., Gregory, M., Kuo, J., & Rajagopal, R. (2022). Five-Year Cost-Effectiveness Modeling of Primary Care-Based, Nonmydriatic Automated Retinal Image Analysis Screening Among Low-Income Patients With Diabetes. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296820967011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.