Advances in Microfluidic Cell Culture Systems for Studying Angiogenesis
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Angiogenesis, the formation of new blood vessels in the vasculature, is a major research topic in biology with implications in development, cancer, tissue engineering, and regenerative medicine. Although much knowledge has been acquired over many decades through application of various angiogenesis assays, these methods have various drawbacks that limit their overall utility. Given the importance of angiogenesis in our understanding of numerous biological processes and its potential as a therapeutic target in cancer and other diseases, there is need to develop useful tools with improved physiological relevance, accessibility, robustness, and throughput over existing assays. Recent developments in microfluidics have demonstrated enormous potential of microscale cell culture systems for biology studies, especially angiogenesis. This area is advancing rapidly, and it is important to remain up to date with the state of the art in technology and evaluate its current and future impact on angiogenesis research. This review examines the latest advances in microfluidic angiogenesis systems. Design and methodology of microscale systems are discussed, and biological insights obtained from the systems are examined. Importantly, physiological relevance, accessibility, and data output of microfluidic angiogenesis systems are compared with traditional angiogenesis assays, and next challenges facing researchers are presented with consideration of the potential integration of automated systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817 · cited 1×
“The most frequently cited limitation of existing in vitro assays, despite their recognized utility thus far in angiogenesis research, is their overall poor physiological context due to the use of nonmicrovascular endothelial cells (bovine aortic endothelial cells and HUVECs are the two most commonly used types); the i…”
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872 · cited 2×
“Other cell types, including pericytes, cancer cells, and leukocytes, were inoculated and cultured in one case to show the robustness of the system for enabling the study of heterotypic endothelial cell–stromal cell interactions.(41) Furthermore, morphological and biochemical characterization of the microvessel network…”
BackgroundMethodFundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Self-citationFluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498
Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
Sung, K. E., Yang, N., Pehlke, C., Keely, P. J., Eliceiri, K. W., Friedl, A., & Beebe, D. J. (2011) · Integr. Biol. · doi:10.1039/c0ib00063a · Cited by 226
Cited by
In Vitro Strategies to Vascularize 3D Physiologically Relevant Models
Dellaquila, A., Le Bao, C., Letourneur, D., & Simon‐Yarza, T. (2021) · Advanced Science · doi:10.1002/advs.202100798 · Cited by 115
Gioiella, F., Urciuolo, F., Imparato, G., Brancato, V., & Netti, P. A. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600772 · Cited by 112
Recapitulating the vasculature using ORGAN-ON-CHIP technology
Pollet, A. M. A. O., & den Toonder, J. M. J. (2020) · Bioengineering · doi:10.3390/bioengineering7010017 · Cited by 73
Metadata
- Authors
- Young, E. W. K.
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 18
- Issue
- 6
- Pages
- 427-436
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W2142566812
- Cited by
- 43
- References
- 7
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advances in Microfluidic Cell Culture Systems for Studying Angiogenesis. https://app.cochat.ai/papers/10.1177/2211068213495206
- The paper
- Young, E. W. K. (2013). Advances in Microfluidic Cell Culture Systems for Studying Angiogenesis. SLAS Technology. https://doi.org/10.1177/2211068213495206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.