Flow cytometric immunophenotyping for hematologic neoplasms
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Flow cytometric immunophenotyping remains an indispensable tool for the diagnosis, classification, staging, and monitoring of hematologic neoplasms. The last 10 years have seen advances in flow cytometry instrumentation and availability of an expanded range of antibodies and fluorochromes that have improved our ability to identify different normal cell populations and recognize phenotypic aberrancies, even when present in a small proportion of the cells analyzed. Phenotypically abnormal populations have been documented in many hematologic neoplasms, including lymphoma, chronic lymphoid leukemias, plasma cell neoplasms, acute leukemia, paroxysmal nocturnal hemoglobinuria, mast cell disease, myelodysplastic syndromes, and myeloproliferative disorders. The past decade has also seen refinement of the criteria used to identify distinct disease entities with widespread adoption of the 2001 World Health Organization (WHO) classification. This classification endorses a multiparametric approach to diagnosis and outlines the morphologic, immunophenotypic, and genotypic features characteristic of each disease entity. When should flow cytometric immunophenotyping be applied? The recent Bethesda International Consensus Conference on flow cytometric immunophenotypic analysis of hematolymphoid neoplasms made recommendations on the medical indications for flow cytometric testing. This review discusses how flow cytometric testing is currently applied in these clinical situations and how the information obtained can be used to direct other testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WHO Classification of Tumours of Haematopoietic and Lymphoid Tissues
Swerdlow, S. H. (2017) · Medical Entomology and Zoology · Cited by 12,933
World Health Organization Classification of Tumours
Fletcher, C., van den Berg, A., & Molenaar, I. (2002) · Cited by 7,079
Hans, C. P. (2004) · Blood · doi:10.1182/blood-2003-05-1545 · Cited by 3,703
Crespo, M., Bosch, F., Villamor, N., Bellosillo, B., Colomer, D., Rozman, M., Marcé, S., López-Guillermo, A., Campo, E., & Montserrat, E. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa023143 · Cited by 1,055
Rassenti, L. Z., Huynh, L., Toy, T. L., Chen, L., Keating, M. J., Gribben, J. G., Neuberg, D. S., Flinn, I. W., Rai, K. R., Byrd, J. C., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040857 · Cited by 745
Hamblin, T. J., Orchard, J. A., Ibbotson, R. E., Davis, Z., Thomas, P. W., Stevenson, F. K., & Oscier, D. G. (2002) · Blood · doi:10.1182/blood.v99.3.1023 · Cited by 618
Proposals for immunological classification of acute leukemias.
van Dongen, J. J. M. (1995) · PubMed · Cited by 544
Valent, P., Horny, H.-P., Bennett, J. M., Fonatsch, C., Germing, U., Greenberg, P., Haferlach, T., Haase, D., Kolb, H.-J., Krieger, O., et al. (2007) · Leukemia Research · doi:10.1016/j.leukres.2006.11.009 · Cited by 513
Schultz, K. R., Pullen, D. J., Sather, H. N., Shuster, J. J., Devidas, M., Borowitz, M. J., Carroll, A. J., Heerema, N. A., Rubnitz, J. E., Loh, M. L., et al. (2007) · Blood · doi:10.1182/blood-2006-01-024729 · Cited by 475
Flow Cytometric Immunophenotypic Analysis of 306 Cases of Multiple Myeloma
Lin, P. Y., Owens, R., Tricot, G. J. K., & Wilson, C. S. (2004) · American Journal of Clinical Pathology · doi:10.1309/74r4-tb90-buwh-27jx · Cited by 454
Cited by
Döhner, H., Estey, E. H., Amadori, S., Appelbaum, F. R., Büchner, T., Burnett, A. K., Dombret, H., Fenaux, P., Grimwade, D., Larson, R. A., et al. (2010) · Blood · doi:10.1182/blood-2009-07-235358 · Cited by 3,373
Data-Driven Phenotypic Dissection of AML Reveals Progenitor-like Cells that Correlate with Prognosis
Levine, J. H., Simonds, E. F., Bendall, S. C., Davis, K. L., Amir, E.-A. D., Tadmor, M. D., Litvin, O., Fienberg, H. G., Jager, A., Zunder, E. R., et al. (2015) · Cell · doi:10.1016/j.cell.2015.05.047 · Cited by 2,303
“Signaling phenotypes define functionally distinct subpopulations Surface markers have become standard tools for clinical diagnosis and monitoring of blood neoplasia (Craig and Foon, 2008).”
InfluentialB lymphocytes: how they develop and function
LeBien, T. W., & Tedder, T. F. (2008) · Blood · doi:10.1182/blood-2008-02-078071 · Cited by 1,400
Wong, K. L., Tai, J. J.-Y., Wong, W.-C., Han, H., Sem, X., Yeap, W.-H., Kourilsky, P., & Wong, S.-C. (2011) · Blood · doi:10.1182/blood-2010-12-326355 · Cited by 1,101
on behalf of the EuroFlow Consortium (EU-FP6, L.-C.-2.-0., van Dongen, J. J. M., Lhermitte, L., Böttcher, S., Almeida, J., van der Velden, V. H. J., Flores-Montero, J., Rawstron, A., Asnafi, V, Lécrevisse, Q., et al. (2012) · Leukemia · doi:10.1038/leu.2012.120 · Cited by 934
EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols
on behalf of the EuroFlow Consortium (EU-FP6, L.-C.-2.-0., Kalina, T., Flores-Montero, J., van der Velden, V. H. J., Martin-Ayuso, M., Böttcher, S., Ritgen, M., Almeida, J., Lhermitte, L., Asnafi, V, et al. (2012) · Leukemia · doi:10.1038/leu.2012.122 · Cited by 783
A deep profiler's guide to cytometry
Bendall, S. C., Nolan, G. P., Roederer, M., & Chattopadhyay, P. K. (2012) · Trends in Immunology · doi:10.1016/j.it.2012.02.010 · Cited by 656
Tumour heterogeneity and metastasis at single-cell resolution
Lawson, D. A., Kessenbrock, K., Davis, R. T., Pervolarakis, N., & Werb, Z. (2018) · Nature Cell Biology · doi:10.1038/s41556-018-0236-7 · Cited by 606
Mass-spectrometric identification and relative quantification of N-linked cell surface glycoproteins
Wollscheid, B., Bausch-Fluck, D., Henderson, C., O'Brien, R., Bibel, M., Schiess, R., Aebersold, R., & Watts, J. D. (2009) · Nature Biotechnology · doi:10.1038/nbt.1532 · Cited by 547
“Finally, the development of a new CD assay is time consuming and expensive: in each case, an optimal antibody needs to be selected, and cell surface expression for the target protein needs to be tested and validated by flow cytometry or immunohistochemistr”
MethodAntibody-Drug Conjugates for Cancer Therapy
Carter, P. J., & Senter, P. D. (2008) · The Cancer Journal · doi:10.1097/ppo.0b013e318172d704 · Cited by 429
Walter, R. B., Gooley, T. A., Wood, B. L., Milano, F., Fang, M., Sorror, M. L., Estey, E. H., Salter, A. I., Lansverk, E., Chien, J. W., et al. (2011) · Journal of Clinical Oncology · doi:10.1200/jco.2010.31.8121 · Cited by 405
Multiple Myeloma, Version 3.2021, NCCN Clinical Practice Guidelines in Oncology
Kumar, S. K., Callander, N. S., Adekola, K., Anderson, L., Baljevic, M., Campagnaro, E., Castillo, J. J., Chandler, J. C., Costello, C., Efebera, Y., et al. (2020) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2020.0057 · Cited by 277
Danilova, L., Anagnostou, V., Caushi, J. X., Sidhom, J.-W., Guo, H., Chan, H. Y., Suri, P., Tam, A., Zhang, J., Asmar, M. E., et al. (2018) · Cancer Immunology Research · doi:10.1158/2326-6066.cir-18-0129 · Cited by 168
Principles of minimal residual disease detection for hematopoietic neoplasms by flow cytometry
Wood, B. L. (2016) · Cytometry Part B: Clinical Cytometry · doi:10.1002/cyto.b.21239 · Cited by 166
Della Porta, M. G., Picone, C., Pascutto, C., Malcovati, L., Tamura, H., Handa, H., Czader, M., Freeman, S., Vyas, P., Porwit, A., et al. (2012) · Haematologica · doi:10.3324/haematol.2011.048421 · Cited by 165
“Flow cytometry immunophenotyping is a reliable method for quantitative and qualitative evaluation of hematopoietic cells and plays an increasingly crucial role in the diagnosis and management of hematologic malignancies.(1,6) Several studies have evaluated flow cytometry as a potential diagnostic tool for MDS.”
BackgroundMethodTranscription factor networks in B-cell differentiation link development to acute lymphoid leukemia
Somasundaram, R., Prasad, M. A. J., Ungerbäck, J., & Sigvardsson, M. (2015) · Blood · doi:10.1182/blood-2014-12-575688 · Cited by 135
Li, S., Li, Y., Yao, J., Chen, B., Song, J., Xue, Q., & Yang, X. (2021) · Cytometry Part A · doi:10.1002/cyto.a.24475 · Cited by 13
“Flow cytometry, as an alternative, could offer high sensitivity, and overcome the throughput limitation of microscopy [9].”
BackgroundMachine Learning Models Improve the Diagnostic Yield of Peripheral Blood Flow Cytometry
Zhang, M. L., Guo, A. X., Kadauke, S., Dighe, A. S., Baron, J. M., & Sohani, A. R. (2020) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqz150 · Cited by 10
Metadata
- Authors
- Craig, F. E., & Foon, K. A.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 2008-04-15
- Volume
- 111
- Issue
- 8
- Pages
- 3941-3967
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W2166355785
- Cited by
- 672
- References
- 58
- FWCI
- 41.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.