CoChat

Lupus anticoagulants: improved diagnosis with a kaolin clotting time using rabbit brain phospholipid in standard and high concentrations

Rosove, MH, Ismail, M, Koziol, BJ, Runge, A, Kasper, CK · 1986 · Blood
Cited by 76

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

We utilized a kaolin-activated partial thromboplastin time (APTT) using rabbit brain phospholipid, in which the capacity of a fourfold increased “high” phospholipid concentration (PC) to normalize the abnormal “standard” PC-APTT in patients with lupus anticoagulants is assessed. This system was also used to measure factors VIIIC, IX, and XI. The tissue thromboplastin inhibition test (TTI), a prothrombin time system in which the activity of a lupus anticoagulant is unmasked by the use of dilute thromboplastin, was simultaneously evaluated. Test sensitivity was defined by results on 31 consecutive patients with standard PC-APTT inhibitors and no bleeding tendency. Specificity was based on 94 patients with various other coagulopathies, including coagulation factor inhibitors, severe congenital factor deficiencies, hepatic insufficiency, and warfarin and heparin treatment. Twenty-one patients with lupus erythematosus and standard PC-APTT results within normal limits were also tested. Sensitivity of the APTT system was superior to that of the TTI (97% v 58%); high PC normalized clotting time ratios and factor levels. Positive results were common with both assays in the group of 20 heparinized patients. The APTT system had superior specificity in remaining cases; there were no positive tests among 74 patients. The lupus erythematosus group had a significant decrease in the clotting time ratio with high PC, indicating that low- level lupus anticoagulants are quite prevalent in this group. The kaolin clotting time using rabbit brain phospholipid in standard and high concentrations is a simple, sensitive, and specific technique for diagnosis of lupus anticoagulants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood.v68.2.472.472

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 76

Metadata

Authors
Rosove, M., Ismail, M., Koziol, B., Runge, A., & Kasper, C.
Venue
Blood
Published
1986-08-01
Volume
68
Issue
2
Pages
472-478
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W134017157
Cited by
76
References
3
FWCI
7.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lupus anticoagulants: improved diagnosis with a kaolin clotting time using rabbit brain phospholipid in standard and high concentrations. https://app.cochat.ai/papers/10.1182/blood.v68.2.472.472
The paper
Rosove, M., Ismail, M., Koziol, B., Runge, A., & Kasper, C. (1986). Lupus anticoagulants: improved diagnosis with a kaolin clotting time using rabbit brain phospholipid in standard and high concentrations. Blood. https://doi.org/10.1182/blood.v68.2.472.472

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.