Effective stimulation of donors for granulocyte transfusions with recombinant methionyl granulocyte colony-stimulating factor [see comments]
Open accessThe DOI matches its Crossref record.
Abstract
Effective granulocyte transfusion (GT) therapy has been hampered by the low yield of neutrophil granulocytes (PMN) obtainable from normal donors even by use of corticosteroid prestimulation, hydroxyethyl starch (HES), and modern leukapheresis (LA) techniques. To increase the PMN yield we performed LA in 22 healthy volunteer donors after a single subcutaneous administration of 300 micrograms of granulocyte colony- stimulating factor (G-CSF) 12 to 16 hours before LA. Five to 7 L of blood was processed within 1.9 to 3 hours using the standard CS- 3000Plus (Baxter, Deerfield, IL) LA protocol including HES. The mean number of PMN harvested was 44.32 +/- 15.5 x 10(9), corresponding to 6.88 +/- 2.1 x 10(9)/L of blood processed. In the final product PMN functions (in vitro: chemotaxis, phagocytosis, chemiluminescence, superoxide anion production; in vivo: chemiluminescence, half-life) were at least normal. In all donors G-CSF induced a consistent increase of white blood cell (mean 16.46 +/- 3.8 x 10(9)/L) and PMN counts (15.94 +/- 3.6 x 10(9)/L). No G-CSF-related side effects were observed and LA was well tolerated. G-CSF prestimulation allows to harvest three to five times higher numbers of functionally normal PMN by LA compared with corticosteroid pretreatment. This may help to overcome one of the major limitations of an effective PMN support.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Groll, A. H., Piscitelli, S. C., & Walsh, T. J. (1998) · Advances in pharmacology · doi:10.1016/s1054-3589(08)60129-5 · Cited by 377
Stroncek, D. F., Clay, M. E., Petzoldt, M. L., Smith, J., Jaszcz, W., Oldham, F. B., & McCullough, J. (1996) · Transfusion · doi:10.1046/j.1537-2995.1996.36796323059.x · Cited by 232
Dale, D. C., Liles, W. C., Llewellyn, C., Rodger, E., & Price, T. H. (1998) · Transfusion · doi:10.1046/j.1537-2995.1998.38898375509.x · Cited by 124
Fan, Y., Teng, Y., Loison, F., Pang, A., Kasorn, A., Shao, X., Zhang, C., Ren, Q., Yu, H., Zheng, Y., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abb1069 · Cited by 36
Hubel, K., Rodger, E., Gaviria, J. M., Price, T. H., Dale, D. C., & Liles, W. C. (2005) · Transfusion · doi:10.1111/j.1537-2995.2005.00636.x · Cited by 34
Metadata
- Authors
- Caspar, C., Seger, R., Burger, J., & Gmur, J.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 1993-06-01
- Volume
- 81
- Issue
- 11
- Pages
- 2866-2871
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W2301701890
- Cited by
- 170
- References
- 0
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effective stimulation of donors for granulocyte transfusions with recombinant methionyl granulocyte colony-stimulating factor [see comments]. https://app.cochat.ai/papers/10.1182/blood.v81.11.2866.2866
- The paper
- Caspar, C., Seger, R., Burger, J., & Gmur, J. (1993). Effective stimulation of donors for granulocyte transfusions with recombinant methionyl granulocyte colony-stimulating factor [see comments]. Blood. https://doi.org/10.1182/blood.v81.11.2866.2866
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.