Saliva cotinine levels in users of electronic cigarettes
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
To the Editors: Electronic nicotine delivery systems (ENDS or electronic cigarettes) look like cigarettes but do not contain or burn tobacco. Instead, they comprise a battery-powered atomiser that produces a vapour for inhalation from cartridges containing humectants (propylene glycol or glycerol), flavours ( e.g. tobacco, mint or fruit) and nicotine. Many smokers report using ENDS to quit smoking or to substitute for tobacco in smoke-free places [1, 2]. ENDS do attenuate craving for tobacco, but appear to deliver little nicotine to the blood [3, 4]. Two studies have evaluated nicotine administration with different ENDS brands in ENDS-naive smokers [3, 4]. In one study, 32 smokers completed two 10-puff “vaping” bouts or smoked a cigarette [3]. In contrast to tobacco cigarettes, ENDS did not increase plasma nicotine reliably (plasma nicotine: 1.4 ng·mL−1 and 0.5 ng·mL−1, respectively, for two ENDS brands). In the other study, smokers used ENDS with a 16-mg nicotine cartridge for 5 min, a nicotine inhaler for 20 min or their usual cigarette for 5 min [4]. Nicotine concentration in plasma, measured after 60 min, was 1.3 ng·mL−1 for ENDS, 2.1 ng·mL−1 for inhalers and 13.4 ng·mL−1 for tobacco cigarettes, but one-third of participants showed no increase in blood nicotine while using the ENDS [4]. The time to maximum concentration of serum nicotine was shorter for ENDS (19.6 min) than for the nicotine inhaler (32.0 min), suggesting some absorption via the respiratory tract [4]. It is possible that serum nicotine levels would have been similar in ENDS and inhaler users, had ENDS users been allowed to use the devices for 20 min as for the inhaler. However, regular ENDS users may draw 120–175 puffs·day−1 on …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of tests used to distinguish smokers from nonsmokers
Jarvis, M. J., Tunstall-Pedoe, H., Feyerabend, C., Vesey, C., & Saloojee, Y. (1987) · American Journal of Public Health · doi:10.2105/ajph.77.11.1435 · Cited by 994
Bullen, C., McRobbie, H., Thornley, S., Glover, M., Lin, R., & Laugesen, M. (2010) · Tobacco Control · doi:10.1136/tc.2009.031567 · Cited by 515
Self-citation
Cited by
E-Cigarettes: A Scientific Review
Grana, R., Benowitz, N., & Glantz, S. A. (2014) · Circulation · doi:10.1161/circulationaha.114.007667 · Cited by 1,194
Caponnetto, P., Campagna, D., Cibella, F., Morjaria, J. B., Caruso, M., Russo, C., & Polosa, R. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066317 · Cited by 711
Etter, J.-F., & Bullen, C. (2011) · Addiction · doi:10.1111/j.1360-0443.2011.03505.x · Cited by 677
Self-citationNicotine Levels in Electronic Cigarettes
Goniewicz, M. L., Kuma, T., Gawron, M., Knysak, J., & Kosmider, L. (2013) · Nicotine & Tobacco Research · doi:10.1093/ntr/nts103 · Cited by 590
Hajek, P., Etter, J., Benowitz, N., Eissenberg, T., & McRobbie, H. (2014) · Addiction · doi:10.1111/add.12659 · Cited by 546
“levels which are close to those obtained from smoking, but only after extended EC use (up to 14 ng/ml after 60 minutes of ad libitum use [33,65,72,94] compared with 10–20 ng/ml after smoking a cigarette) [95,96].”
BackgroundSelf-citationWilliams, M., Villarreal, A., Bozhilov, K., Lin, S., & Talbot, P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057987 · Cited by 530
A systematic review of health effects of electronic cigarettes
Pisinger, C., & Døssing, M. (2014) · Preventive Medicine · doi:10.1016/j.ypmed.2014.10.009 · Cited by 484
Brown, J., Beard, E., Kotz, D., Michie, S., & West, R. (2014) · Addiction · doi:10.1111/add.12623 · Cited by 478
Overview of Electronic Nicotine Delivery Systems: A Systematic Review
Glasser, A. M., Collins, L., Pearson, J. L., Abudayyeh, H., Niaura, R. S., Abrams, D. B., & Villanti, A. C. (2017) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2016.10.036 · Cited by 473
‘Vaping’ profiles and preferences: an online survey of electronic cigarette users
Dawkins, L., Turner, J., Roberts, A., & Soar, K. (2013) · Addiction · doi:10.1111/add.12150 · Cited by 461
Pepper, J. K., & Brewer, N. T. (2014) · Tobacco Control · doi:10.1136/tobaccocontrol-2013-051122 · Cited by 418
Secondhand Exposure to Vapors From Electronic Cigarettes
Czogala, J., Goniewicz, M. L., Fidelus, B., Zielinska-Danch, W., Travers, M. J., & Sobczak, A. (2014) · Nicotine & Tobacco Research · doi:10.1093/ntr/ntt203 · Cited by 401
Chemical hazards present in liquids and vapors of electronic cigarettes
Hutzler, C., Paschke, M., Kruschinski, S., Henkler, F., Hahn, J., & Luch, A. (2014) · Archives of Toxicology · doi:10.1007/s00204-014-1294-7 · Cited by 348
Electronic Cigarettes: Effective Nicotine Delivery After Acute Administration
Vansickel, A. R., & Eissenberg, T. (2013) · Nicotine & Tobacco Research · doi:10.1093/ntr/ntr316 · Cited by 346
Nicotine delivery, retention and pharmacokinetics from various electronic cigarettes
St.Helen, G., Havel, C., Dempsey, D. A., Jacob, P., & Benowitz, N. L. (2016) · Addiction · doi:10.1111/add.13183 · Cited by 276
Hitchman, S. C., Brose, L. S., Brown, J., Robson, D., & McNeill, A. (2015) · Nicotine & Tobacco Research · doi:10.1093/ntr/ntv078 · Cited by 274
A longitudinal study of electronic cigarette users
Etter, J.-F., & Bullen, C. (2014) · Addictive Behaviors · doi:10.1016/j.addbeh.2013.10.028 · Cited by 263
Self-citationBrown, J., West, R., Beard, E., Michie, S., Shahab, L., & McNeill, A. (2014) · Addictive Behaviors · doi:10.1016/j.addbeh.2014.03.009 · Cited by 242
Analysis of refill liquids for electronic cigarettes
Etter, J., Zäther, E., & Svensson, S. (2013) · Addiction · doi:10.1111/add.12235 · Cited by 232
Self-citationAdriaens, K., Van Gucht, D., Declerck, P., & Baeyens, F. (2014) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph111111220 · Cited by 224
The emerging phenomenon of electronic cigarettes
Caponnetto, P., Campagna, D., Papale, G., Russo, C., & Polosa, R. (2012) · Expert Review of Respiratory Medicine · doi:10.1586/ers.11.92 · Cited by 210
Palazzolo, D. L. (2013) · Frontiers in Public Health · doi:10.3389/fpubh.2013.00056 · Cited by 197
“According to Bullen et al. (59), serum levels of nicotine were similar after use of either the Nicotrol® inhaler or a Ruyan® e-cigarette.”
BackgroundInfluentialElectronic Cigarette Aerosol Modulates the Oral Microbiome and Increases Risk of Infection
Pushalkar, S., Paul, B., Li, Q., Yang, J., Vasconcelos, R., Makwana, S., González, J. M., Shah, S., Xie, C., Janal, M. N., et al. (2020) · iScience · doi:10.1016/j.isci.2020.100884 · Cited by 173
Paek, H.-J., Kim, S., Hove, T., & Huh, J. Y. (2014) · Journal of Health Communication · doi:10.1080/10810730.2013.821560 · Cited by 162
Clinical laboratory assessment of the abuse liability of an electronic cigarette
Vansickel, A. R., Weaver, M. F., & Eissenberg, T. (2012) · Addiction · doi:10.1111/j.1360-0443.2012.03791.x · Cited by 160
Kaur, G., Muthumalage, T., & Rahman, I. (2018) · Toxicology Letters · doi:10.1016/j.toxlet.2018.02.025 · Cited by 159
“Although carcinogens appear to be reduced or eliminated in e-cigarettes (Cahn and Siegel, 2011; Cobb and Abrams, 2011; Etter and Bullen, 2011), health concerns of ecigarette aerosols with flavoring chemicals including their enhancers based on toxicological effects on the lungs are not well…”
BackgroundElectronic cigarettes and nicotine clinical pharmacology
Schroeder, M. J., & Hoffman, A. C. (2014) · Tobacco Control · doi:10.1136/tobaccocontrol-2013-051469 · Cited by 158
“Nevertheless, these data suggest that e-cigarettes are able to deliver suf fi cient nicotine for physiological effects.”
Background
Metadata
- Authors
- Etter, J.-F., & Bullen, C.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2011-10-31
- Volume
- 38
- Issue
- 5
- Pages
- 1219-1220
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2025888547
- Cited by
- 118
- References
- 2
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.