Meta-analysis of quantitative diffusion-weighted MR imaging in the differential diagnosis of breast lesions
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To determine, in a meta-analysis, the diagnostic performance of quantitative diffusion-weighted (DW) MR imaging in patients with breast lesions. METHODS: English and Chinese studies published prior to June 2009 to assess the diagnostic performance of quantitative DWI in patients with breast lesions were reviewed and summarized with reference to the inclusion and exclusion criteria. Methodological quality was assessed by using the quality assessment of diagnostic studies (QUADAS) instrument. Publication bias analysis was performed by using Comprehensive Meta-analysis version 2. Meta-Disc version 1.4 was used to describe primary results and explore homogeneity by Chi-square test and inconsistency index; to explore threshold effect by receiver operator characteristic (ROC) space and Spearman correlation coefficient; and to pool weighted sensitivity and specificity by fixed or random effect model. A summary ROC (sROC) curve was constructed to calculate the area under the curve (AUC). RESULTS: Of 65 eligible studies, 13 with 615 malignant and 349 benign lesions were included in the original meta-analysis, among which heterogeneity arising from factors other than threshold effect and publication bias was explored. Methodological quality was moderate. The pooled weighted sensitivity and specificity with corresponding 95% confidence interval (CI) in one homogenous subgroup of studies using maximum b = 1000 s/mm2 were 0.84 (0.80, 0.87) and 0.84 (0.79, 0.88) respectively. AUC of sROC was 0.9085. Sensitivity analysis demonstrated that the pooled estimates were stable and reliable. CONCLUSIONS: Quantitative DWI has a higher specificity to differentiate between benign and malignant breast lesions compared to that of contrast-enhanced MRI. However, large scale randomized control trials (RCTs) are necessary to assess its clinical value because of disunified diffusion gradient factor b and diagnosis threshold.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 1×
“I(2) > 50% suggests heterogeneity [22].”
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679 · cited 1×
“Breast cancer is the most common cancer in women worldwide [ 1 ].”
Global Cancer Statistics, 2002
Parkin, D. M., Bray, F., Ferlay, J., & Pisani, P. (2005) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.55.2.74 · Cited by 18,196
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
A Fail-Safe N for Effect Size in Meta-Analysis
Orwin, R. G. (1983) · Journal of Educational Statistics · doi:10.2307/1164923 · Cited by 2,064 · cited 1×
“NFS refers to the exact number of hypothetical studies with null results that would be required to nullify the statistical significance of combined effect [27].”
BackgroundDiffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Koh, D.-M., & Collins, D. J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1403 · Cited by 1,993
Meta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Kriege, M., Brekelmans, C. T. M., Boetes, C., Besnard, P. E., Zonderland, H. M., Obdeijn, I. M., Manoliu, R. A., Kok, T., Peterse, H., Tilanus-Linthorst, M. M. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa031759 · Cited by 1,687
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
Cited by
Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review
Guo, R., Lu, G., Qin, B., & Fei, B. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.09.012 · Cited by 542
On behalf of the EUSOBI international Breast Diffusion-Weighted Imaging working group, Baltzer, P., Mann, R. M., Iima, M., Sigmund, E. E., Clauser, P., Gilbert, F. J., Martincich, L., Partridge, S. C., Patterson, A., et al. (2020) · European Radiology · doi:10.1007/s00330-019-06510-3 · Cited by 437
Diffusion-weighted breast MRI: Clinical applications and emerging techniques
Partridge, S. C., Nissan, N., Rahbar, H., Kitsch, A. E., & Sigmund, E. E. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25479 · Cited by 340
Bogner, W., Pinker-Domenig, K., Bickel, H., Chmelik, M., Weber, M., Helbich, T. H., Trattnig, S., & Gruber, S. (2012) · Radiology · doi:10.1148/radiol.12111494 · Cited by 204
“Our results were slightly better than the average results for DW imaging of the breast according to a recent meta-analysis (11).”
ResultLiu, C., Liang, C., Liu, Z., Zhang, S., & Huang, B. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.08.006 · Cited by 202
Diffusion Weighted Magnetic Resonance Imaging of the Breast
Partridge, S. C., & McDonald, E. S. (2013) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2013.04.007 · Cited by 189
Diffusion MRI of the breast: Current status and future directions
Iima, M., Honda, M., Sigmund, E. E., Ohno Kishimoto, A., Kataoka, M., & Togashi, K. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26908 · Cited by 187
Zhang, L., Tang, M., Min, Z., Lu, J., Lei, X., & Zhang, X. (2016) · Acta Radiologica · doi:10.1177/0284185115597265 · Cited by 169
“Compared with DCE-MRI, DWI has a higher specificity but lower sensitivity (9), but numerous studies have shown that together with apparent diffusion coefficient (ADC) maps, DWI may provide additional specificity and potential value, improving the positive predictive value from 37% to 47% (10–14).”
BackgroundPinker, K., Moy, L., Sutton, E. J., Mann, R. M., Weber, M., Thakur, S. B., Jochelson, M. S., Bago-Horvath, Z., Morris, E. A., Baltzer, P. A., et al. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000465 · Cited by 163
Metadata
- Authors
- Chen, X., Li, W.-L., Zhang, Y.-L., Wu, Q., Guo, Y.-M., & Bai, Z.-L.
- Venue
- BMC Cancer
- Published
- 2010-12
- Volume
- 10
- Issue
- 1
- Pages
- 693-693
- ISSN
- 1471-2407 (ISSN-L)
- OpenAlex
- W2014162604
- Cited by
- 209
- References
- 29
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.