Kinetic analysis of dynamic 18F-fluoromisonidazole PET correlates with radiation treatment outcome in head-and-neck cancer
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Hypoxia compromises local control in patients with head-and-neck cancer (HNC). In order to determine the value of [18 F]-fluoromisonidazole (Fmiso) with regard to tumor hypoxia, a patient study with dynamic Fmiso PET was performed. For a better understanding of tracer uptake and distribution, a kinetic model was developed to analyze dynamic Fmiso PET data. Methods: For 15 HNC patients, dynamic Fmiso PET examinations were performed prior to radiotherapy (RT) treatment. The data was analyzed using a two compartment model, which allows the determination of characteristic hypoxia and perfusion values. For different parameters, such as patient age, tumor size and standardized uptake value, the correlation to treatment outcome was tested using the Wilcoxon-Mann-Whitney U-test. Statistical tests were also performed for hypoxia and perfusion parameters determined by the kinetic model and for two different metrics based on these parameters. Results: The kinetic Fmiso analysis extracts local hypoxia and perfusion characteristics of a tumor tissue. These parameters are independent quantities. In this study, different types of characteristic hypoxia-perfusion patterns in tumors could be identified. The clinical verification of the results, obtained on the basis of the kinetic analysis, showed a high correlation of hypoxia-perfusion patterns and RT treatment outcome (p = 0.001) for this initial patient group. Conclusion: The presented study established, that Fmiso PET scans may benefit from dynamic acquisition and analysis by a kinetic model. The pattern of distribution of perfusion and hypoxia in the tissue is correlated to local control in HNC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nordsmark, M., Overgaard, M., & Overgaard, J. (1996) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(96)91811-3 · Cited by 942
Intratumoral pO2 predicts survival in advanced cancer of the uterine cervix
Höckel, M., Knoop, C., Schlenger, K., Vorndran, B., Bauβnann, E., Mitze, M., Knapstein, P. G., & Vaupel, P. (1993) · Radiotherapy and Oncology · doi:10.1016/0167-8140(93)90025-4 · Cited by 809 · cited 1×
“Hypoxia has also been related to lower survival probability and higher risk of recurrence in patients with cervix cancer [4, 10 ].”
Background
Cited by
Imaging hypoxia to improve radiotherapy outcome
Horsman, M. R., Mortensen, L. S., Petersen, J. B., Busk, M., & Overgaard, J. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.171 · Cited by 614
Skeletal PET with18F-Fluoride: Applying New Technology to an Old Tracer
Grant, F. D., Fahey, F. H., Packard, A. B., Davis, R. T., Alavi, A., & Treves, S. T. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037200 · Cited by 520
Use of PET and PET/CT for Radiation Therapy Planning: IAEA expert report 2006–2007
MacManus, M., Nestle, U., Rosenzweig, K. E., Carrio, I., Messa, C., Belohlavek, O., Danna, M., Inoue, T., Deniaud-Alexandre, E., Schipani, S., et al. (2009) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2008.11.008 · Cited by 367
Imaging tumour hypoxia with positron emission tomography
Fleming, I. N., Manavaki, R., Blower, P. J., West, C., Williams, K. J., Harris, A. L., Domarkas, J., Lord, S., Baldry, C., & Gilbert, F. J. (2015) · British Journal of Cancer · doi:10.1038/bjc.2014.610 · Cited by 330
Imaging oxygenation of human tumours
Padhani, A. R., Krohn, K. A., Lewis, J. S., & Alber, M. (2007) · European Radiology · doi:10.1007/s00330-006-0431-y · Cited by 328
Self-citationMortensen, L. S., Johansen, J., Kallehauge, J., Primdahl, H., Busk, M., Lassen, P., Alsner, J., Sørensen, B. S., Toustrup, K., Jakobsen, S., et al. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.09.015 · Cited by 308
Hypoxia Dose Painting by Numbers: A Planning Study
Thorwarth, D., Eschmann, S.-M., Paulsen, F., & Alber, M. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.11.061 · Cited by 301
Self-citationZips, D., Zöphel, K., Abolmaali, N., Perrin, R., Abramyuk, A., Haase, R., Appold, S., Steinbach, J., Kotzerke, J., & Baumann, M. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.08.019 · Cited by 280
Lee, N. Y., Mechalakos, J. G., Nehmeh, S., Lin, Z., Squire, O. D., Cai, S., Chan, K., Zanzonico, P. B., Greco, C., Ling, C. C., et al. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.06.039 · Cited by 235
Grosu, A.-L., Souvatzoglou, M., Röper, B., Dobritz, M., Wiedenmann, N., Jacob, V., Wester, H.-J., Reischl, G., Machulla, H.-J., Schwaiger, M., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.05.079 · Cited by 229
Multiparametric Imaging of Tumor Response to Therapy
Padhani, A. R., & Miles, K. A. (2010) · Radiology · doi:10.1148/radiol.10091760 · Cited by 222
The Meaning, Measurement and Modification of Hypoxia in the Laboratory and the Clinic
Hammond, E. M., Asselin, M.-C., Forster, D., O'Connor, J. P. B., Senra, J. M., & Williams, K. J. (2014) · Clinical Oncology · doi:10.1016/j.clon.2014.02.002 · Cited by 217
“dynamic imaging with different modelling approaches can potentially characterise both perfusion and retention and allow hypoxia perfusion patterns to be identified [100,101].”
BackgroundNestle, U., Kremp, S., & Grosu, A.-L. (2006) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2006.09.011 · Cited by 214
Tumour hypoxia imaging with [18F]FAZA PET in head and neck cancer patients: a pilot study
Souvatzoglou, M., Grosu, A. L., Röper, B., Krause, B. J., Beck, R., Reischl, G., Picchio, M., Machulla, H.-J., Wester, H.-J., & Piert, M. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0424-3 · Cited by 172
“These observations, as well as recent studies performed with [(18)F]FMISO, suggest that more refined data analysis including compartmental analysis [19] or parametric imaging [30] should be considered to better characterise tracer kinetics.”
Molecular mechanisms of hypoxia in cancer
Challapalli, A., Carroll, L., & Aboagye, E. O. (2017) · Clinical and Translational Imaging · doi:10.1007/s40336-017-0231-1 · Cited by 163
Thorwarth, D., Eschmann, S.-M., Holzner, F., Paulsen, F., & Alber, M. (2006) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2006.07.033 · Cited by 160
Self-citation18F-FLT PET/CT for Early Response Monitoring and Dose Escalation in Oropharyngeal Tumors
Troost, E. G. C., Bussink, J., Hoffmann, A. L., Boerman, O. C., Oyen, W. J. G., & Kaanders, J. H. A. M. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069310 · Cited by 158
Hypoxia and the phenomenon of immune exclusion
Pietrobon, V., & Marincola, F. M. (2021) · Journal of Translational Medicine · doi:10.1186/s12967-020-02667-4 · Cited by 119
Metadata
- Authors
- Thorwarth, D., Eschmann, S.-M., Scheiderbauer, J., Paulsen, F., & Alber, M.
- Venue
- BMC Cancer
- Published
- 2005-12
- Volume
- 5
- Issue
- 1
- Pages
- 152-152
- ISSN
- 1471-2407 (ISSN-L)
- OpenAlex
- W1587146634
- Cited by
- 169
- References
- 2
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.