A simple technique for quantifying apoptosis in 96-well plates
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Background: Analyzing apoptosis has been an integral component of many biological studies. However, currently available methods for quantifying apoptosis have various limitations including multiple, sometimes cell-damaging steps, the inability to quantify live, necrotic and apoptotic cells at the same time, and non-specific detection (i.e. "false positive"). To overcome the shortcomings of current methods that quantify apoptosis in vitro and to take advantage of the 96-well plate format, we present here a modified ethidium bromide and acridine orange (EB/AO) staining assay, which may be performed entirely in a 96-well plate. Our method combines the advantages of the 96-well format and the conventional EB/AO method for apoptotic quantification. Results: We compared our method and the conventional EB/AO method for quantifying apoptosis of suspension cells (Jurkat) and adherent cells (A375) under normal growth and apoptosis-inducing conditions. We found that our new EB/AO method achieved quantification results comparable to those produced using the conventional EB/AO method for both suspension and adherent cells. Conclusion: By eliminating the detaching and washing steps, our method drastically reduces the time needed to perform the test, minimizes damage to adherent cells, and decreases the possibility of losing floating cells. Overall, our method is an improvement over the currently available techniques especially for adherent cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thornberry, N. A., & Lazebnik, Y. (1998) · Science · doi:10.1126/science.281.5381.1312 · Cited by 6,887
Vermes, I., Haanen, C., Steffens-Nakken, H., & Reutellingsperger, C. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(95)00072-i · Cited by 5,410
Glucocorticoid-induced thymocyte apoptosis is associated with endogenous endonuclease activation
Wyllie, A. H. (1980) · Nature · doi:10.1038/284555a0 · Cited by 4,504
Current Protocols in Immunology
(2018) · Current Protocols in Immunology · doi:10.1002/(issn)1934-368x · Cited by 3,566
Martin, S. J., Reutelingsperger, C. P., McGahon, A. J., Rader, J. A., van Schie, R. C., LaFace, D. M., & Green, D. R. (1995) · The Journal of experimental medicine · doi:10.1084/jem.182.5.1545 · Cited by 2,824 · cited 1×
“Currently, methods available to help detect apoptosis in vitro include several morphological staining methods (such as ethidium bromide and acridine orange (EB/AO) [1,2], DAPI (4; 6-diamidino-2phenylidole) [2], Hoechst staining [2], and etc), Annexin V staining [3-6], DNA ladder [7,8], TUNEL (Terminal deoxynucleotidyl…”
A Combinatorial Approach Defines Specificities of Members of the Caspase Family and Granzyme B
Thornberry, N. A., Rano, T. A., Peterson, E. P., Rasper, D. M., Timkey, T., Garcia-Calvo, M., Houtzager, V. M., Nordstrom, P. A., Roy, S., Vaillancourt, J. P., et al. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.29.17907 · Cited by 2,068
Cohen, J. J. (1993) · Immunology Today · doi:10.1016/0167-5699(93)90214-6 · Cited by 987
Walker, N. I., HARMON, B. V., Gobe, G. C., & Kerr, J. F. R. (1988) · PubMed · Cited by 527
Homburg, C., de Haas, M., von dem Borne, A., Verhoeven, A., Reutelingsperger, C., & Roos, D. (1995) · Blood · doi:10.1182/blood.v85.2.532.532 · Cited by 431
Mechanisms of Apoptosis: Integration of Genetic, Biochemical, and Cellular Indicators
Stewart, B. W. (1994) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/86.17.1286 · Cited by 320
Monoclonal Antibody to Single-Stranded DNA Is a Specific and Sensitive Cellular Marker of Apoptosis
Frankfurt, O. S., Robb, J. A., Sugarbaker, E. V., & Villa, L. (1996) · Experimental Cell Research · doi:10.1006/excr.1996.0240 · Cited by 244
Apoptosis: Identification of dying cells
Renvoizé, C., Biola, A., Pallardy, M., & Bréard, J. (1998) · Cell Biology and Toxicology · doi:10.1023/a:1007429904664 · Cited by 239
Labelling DNA strand breaks with BrdUTP. Detection of apoptosis and cell proliferation
Li, X., & Darzynkiewicz, Z. (1995) · Cell Proliferation · doi:10.1111/j.1365-2184.1995.tb00045.x · Cited by 207
Li, X., Traganos, F., Melamed, M. R., & Darzynkiewicz, Z. (1995) · Cytometry · doi:10.1002/cyto.990200210 · Cited by 173
Identification of Apoptotic Cells by Formamide-induced DNA Denaturation in Condensed Chromatin
Frankfurt, O. S., & Krishan, A. (2001) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215540104900311 · Cited by 169
Boersma, A. W. M., Nooter, K., Oostrum, R. G., & Stoter, G. (1996) · Cytometry · doi:10.1002/(sici)1097-0320(19960601)24:2<123::aid-cyto4>3.0.co;2-k · Cited by 151
Frankfurt, O. S., & Krishan, A. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00387-8 · Cited by 101
Homogeneous Time-Resolved Fluorescence Quenching Assay (LANCE) for Caspase-3 ,
Karvinen, J. T., Hurskainen, P., Gopalakrishnan, S. M., Burns, D., Warrior, U., & Hemmilä, I. A. (2002) · SLAS DISCOVERY · doi:10.1177/108705710200700306 · Cited by 74
Identification of a transitional preapoptotic population of thymocytes
Cohen, G. M., Sun, X., Snowden, R. T., Ormerod, M. G., & Dinsdale, D. D. (1993) · The Journal of Immunology · doi:10.4049/jimmunol.151.11.6616.b · Cited by 66
Identification of a transitional preapoptotic population of thymocytes.
Cohen, G. M., Sun, X. M., Snowden, R. T., Ormerod, M. G., & Dinsdale, D. D. (1993) · The Journal of Immunology · doi:10.4049/jimmunol.151.2.566 · Cited by 57
Immunoassay for Single-Stranded DNA in Apoptotic Cells
Frankfurt, O. S. (2004) · Humana Press eBooks · doi:10.1385/1-59259-812-9:085 · Cited by 39
Cited by
Dual AO/EB Staining to Detect Apoptosis in Osteosarcoma Cells Compared with Flow Cytometry
Liu, K., Liu, P.-C., Liu, R., & Wu, X. (2015) · Medical Science Monitor Basic Research · doi:10.12659/msmbr.893327 · Cited by 770
Peto's Paradox: evolution's prescription for cancer prevention
Caulin, A. F., & Maley, C. C. (2011) · Trends in Ecology & Evolution · doi:10.1016/j.tree.2011.01.002 · Cited by 384
Cell‐death assessment by fluorescent and nonfluorescent cytosolic and nuclear staining techniques
ATALE, N., GUPTA, S., YADAV, U. C. S., & RANI, V. (2014) · Journal of Microscopy · doi:10.1111/jmi.12133 · Cited by 357
Nanayakkara, A. K., Follit, C. A., Chen, G., Williams, N. S., Vogel, P. D., & Wise, J. G. (2018) · Scientific Reports · doi:10.1038/s41598-018-19325-x · Cited by 282
Kamarajan, P., Hayami, T., Matte, B., Liu, Y., Danciu, T., Ramamoorthy, A., Worden, F., Kapila, S., & Kapila, Y. (2015) · PLOS ONE · doi:10.1371/journal.pone.0131008 · Cited by 214
Metadata
- Authors
- Ribble, D., Goldstein, N. B., Norris, D. A., & Shellman, Y. G.
- Venue
- BMC Biotechnology
- Published
- 2005-05-10
- Volume
- 5
- Issue
- 1
- Pages
- 12-12
- ISSN
- 1472-6750 (ISSN-L)
- OpenAlex
- W1539469412
- Cited by
- 850
- References
- 21
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.