Abstract
BACKGROUND: Based upon defining a common reference point, current real-time quantitative PCR technologies compare relative differences in amplification profile position. As such, absolute quantification requires construction of target-specific standard curves that are highly resource intensive and prone to introducing quantitative errors. Sigmoidal modeling using nonlinear regression has previously demonstrated that absolute quantification can be accomplished without standard curves; however, quantitative errors caused by distortions within the plateau phase have impeded effective implementation of this alternative approach. RESULTS: Recognition that amplification rate is linearly correlated to amplicon quantity led to the derivation of two sigmoid functions that allow target quantification via linear regression analysis. In addition to circumventing quantitative errors produced by plateau distortions, this approach allows the amplification efficiency within individual amplification reactions to be determined. Absolute quantification is accomplished by first converting individual fluorescence readings into target quantity expressed in fluorescence units, followed by conversion into the number of target molecules via optical calibration. Founded upon expressing reaction fluorescence in relation to amplicon DNA mass, a seminal element of this study was to implement optical calibration using lambda gDNA as a universal quantitative standard. Not only does this eliminate the need to prepare target-specific quantitative standards, it relegates establishment of quantitative scale to a single, highly defined entity. The quantitative competency of this approach was assessed by exploiting "limiting dilution assay" for absolute quantification, which provided an independent gold standard from which to verify quantitative accuracy. This yielded substantive corroborating evidence that absolute accuracies of +/- 25% can be routinely achieved. Comparison with the LinReg and Miner automated qPCR data processing packages further demonstrated the superior performance of this kinetic-based methodology. CONCLUSION: Called "linear regression of efficiency" or LRE, this novel kinetic approach confers the ability to conduct high-capacity absolute quantification with unprecedented quality control capabilities. The computational simplicity and recursive nature of LRE quantification also makes it amenable to software implementation, as demonstrated by a prototypic Java program that automates data analysis. This in turn introduces the prospect of conducting absolute quantification with little additional effort beyond that required for the preparation of the amplification reactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
Assumption-free analysis of quantitative real-time polymerase chain reaction (PCR) data
Ramakers, C., Ruijter, J. M., Deprez, R. H. L., & Moorman, A. F. M. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(02)01423-4 · Cited by 3,709 · cited 2×
“Based upon the presumption that amplification efficiency is constant within this region, amplification efficiency is determined from the slope of a Log(FC) vs. cycle plot, with target quantity (F 0 ) determined by the intercept, that is, when cycle = 0 [ 12 ].”
MethodQuantification of mRNA using real-time RT-PCR
Nolan, T., Hands, R. E., & Bustin, S. A. (2006) · Nature Protocols · doi:10.1038/nprot.2006.236 · Cited by 2,247 · cited 1×
“Exacerbated by a profound lack of standardization, it is not surprising that many reports caution about the limitations of real-time qPCR [28,37-39].”
BackgroundKinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159 · cited 1×
“Absolute quantification via Ct Positional analysis, as exemplified by the threshold method, has predominated since the introduction of realtime PCR over 15 years ago [35], and is the quantitative methodology upon which all commercial platforms currently rely.”
MethodConcordance among Gene-Expression–Based Predictors for Breast Cancer
Fan, C., Oh, D. S., Wessels, L., Weigelt, B., Nuyten, D. S. A., Nobel, A. B., van't Veer, L. J., & Perou, C. M. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052933 · Cited by 1,341
Comprehensive Algorithm for Quantitative Real-Time Polymerase Chain Reaction
Zhao, S., & Fernald, R. D. (2005) · Journal of Computational Biology · doi:10.1089/cmb.2005.12.1047 · Cited by 1,303 · cited 11×
“Both Miner and LinReg performed less well, producing 2.4X and 6.1X Screen shot of a prototypic Java program that automates LRE quantificationFigure 11 Screen shot of a prototypic Java program that automates LRE quantification.”
MethodInfluentialBuyse, M., Loi, S., van't Veer, L., Viale, G., Delorenzi, M., Glas, A. M., Saghatchian d'Assignies, M., Bergh, J., Lidereau, R., Ellis, P., et al. (2006) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djj329 · Cited by 1,238 · cited 1×
“Founded upon the expectation that gene expression analysis can be used as a diagnostic tool to both predict and follow therapeutic outcomes [4,5], many studies have reported that effective diagnoses can be achieved with relatively small groups of biomarker transcripts, numbering between 10 and 100 [6,7], a range that…”
BackgroundPeirson, S. N. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng073 · Cited by 843 · cited 1×
“These include determining amplification efficiency through the application of exponential mathematics to the log-linear region, using either linear regression [10-13] or nonlinear regression [14,15].”
MethodEvaluation of DNA microarray results with quantitative gene expression platforms
Canales, R. D., Luo, Y., Willey, J. C., Austermiller, B., Barbacioru, C. C., Boysen, C., Hunkapiller, K., Jensen, R. V., Knight, C. R., Lee, K. Y., et al. (2006) · Nature Biotechnology · doi:10.1038/nbt1236 · Cited by 615 · cited 1×
“Historically, real-time qPCR has largely been relegated to a supportive role in large-scale gene expression studies, most frequently used for the verification of DNA microarray datasets [1-3].”
BackgroundReliability and reproducibility issues in DNA microarray measurements
DRAGHICI, S., KHATRI, P., EKLUND, A., & SZALLASI, Z. (2006) · Trends in Genetics · doi:10.1016/j.tig.2005.12.005 · Cited by 590 · cited 2×
“Nevertheless, absolute qPCR has the potential to extend gene expression analysis beyond what is possible with microarray analysis, based upon the innate capability to overcome two of the greatest limitations of microarray quantification, which are limited sensitivity and lack of absolute scale [4].”
BackgroundMathematics of quantitative kinetic PCR and the application of standard curves
Rutledge, R. G. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng093 · Cited by 545 · cited 6×
“Absolute quantification is accomplished via standard curves constructed with target-specific quantified standards [9], which are technically challenging and prone to generating quantitative errors.”
BackgroundMethodInfluentialSelf-citationLiu, W., & Saint, D. A. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5530 · Cited by 516 · cited 3×
“These include determining amplification efficiency through the application of exponential mathematics to the log-linear region, using either linear regression [10-13] or nonlinear regression [14,15].”
MethodČikoš, Š., Bukovská, A., & Koppel, J. (2007) · BMC Molecular Biology · doi:10.1186/1471-2199-8-113 · Cited by 392 · cited 4×
“(2007) reported problems with background subtraction with their Mx3000P platform which required them to conduct SCF analysis using raw fluorescence data [31].”
MethodInfluentialStatistical significance of quantitative PCR
Karlen, Y., McNair, A., Perseguers, S., Mazza, C., & Mermod, N. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-131 · Cited by 373
Validation of a quantitative method for real time PCR kinetics
Liu, W., & Saint, D. A. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)00478-3 · Cited by 359 · cited 1×
“Attempts to model the entire amplification profile have included sigmoidal modeling using nonlinear regression [16-20], in addition to the application of various biochemical-based models [21-23], and other forms of mathematical modeling [24-26].”
MethodWang, Y., Barbacioru, C., Hyland, F., Xiao, W., Hunkapiller, K. L., Blake, J., Chan, F., Gonzalez, C., Zhang, L., & Samaha, R. R. (2006) · BMC Genomics · doi:10.1186/1471-2164-7-59 · Cited by 308 · cited 1×
“Historically, real-time qPCR has largely been relegated to a supportive role in large-scale gene expression studies, most frequently used for the verification of DNA microarray datasets [1-3].”
BackgroundRutledge, R. G. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh177 · Cited by 209 · cited 15×
“This subsequently required exclusion of the plateau cycles from the nonlinear regression, based upon a somewhat esoteric method for selecting a "cutoff cycle" [18].”
BackgroundMethodInfluentialSelf-citationEvaluation of methods for oligonucleotide array data via quantitative real-time PCR
Qin, L., Beyer, R. P., Hudson, F. N., Linford, N. J., Morris, D. E., & Kerr, K. F. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-23 · Cited by 128 · cited 1×
“Historically, real-time qPCR has largely been relegated to a supportive role in large-scale gene expression studies, most frequently used for the verification of DNA microarray datasets [1-3].”
BackgroundKinetic Outlier Detection (KOD) in real-time PCR
Bar, T. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng106 · Cited by 102 · cited 1×
“These include determining amplification efficiency through the application of exponential mathematics to the log-linear region, using either linear regression [10-13] or nonlinear regression [14,15].”
MethodMathematical model of real‐time PCR kinetics
Gevertz, J. L., DUNN, S. M., & Roth, C. M. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20617 · Cited by 102 · cited 1×
“Attempts to model the entire amplification profile have included sigmoidal modeling using nonlinear regression [16-20], in addition to the application of various biochemical-based models [21-23], and other forms of mathematical modeling [ 24-26 ].”
MethodHigh-Resolution Semi-Quantitative Real-Time PCR without the Use of a Standard Curve
Gentle, A., Anastasopoulos, F., & McBrien, N. A. (2001) · BioTechniques · doi:10.2144/01313st03 · Cited by 96
Tichopád, A., Džidić, A., & Pfaffl, M. W. (2002) · Biotechnology Letters · doi:10.1023/a:1021319421153 · Cited by 71 · cited 1×
“Attempts to model the entire amplification profile have included sigmoidal modeling using nonlinear regression [ 16-20 ], in addition to the application of various biochemical-based models [21-23], and other forms of mathematical modeling [24-26].”
MethodRelative transcript quantification by Quantitative PCR: Roughly right or precisely wrong?
Skern‐Mauritzen, R., Frost, P., & Nilsen, F. (2005) · BMC Molecular Biology · doi:10.1186/1471-2199-6-10 · Cited by 71
Evaluation of absolute quantitation by nonlinear regression in probe-based real-time PCR
Goll, R., Olsen, T., Cui, G., & Florholmen, J. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-107 · Cited by 57 · cited 1×
“Demonstration that absolute quantification can be achieved by combining optical calibration with sigmoidal modeling (a method called "sigmoidal curve fitting" or SCF [18]) has led several groups to evaluate this approach as an alternative to standard curve-based quantification [ 27-33 ].”
MethodA kinetic model of quantitative real‐time polymerase chain reaction
Mehra, S., & Hu, W. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20555 · Cited by 51 · cited 1×
“Attempts to model the entire amplification profile have included sigmoidal modeling using nonlinear regression [16-20], in addition to the application of various biochemical-based models [21-23], and other forms of mathematical modeling [24-26].”
MethodModel based analysis of real-time PCR data from DNA binding dye protocols
Alvarez, M. J., Vilá‐Ortíz, G. J., Salibe, M., Podhajcer, O. L., & Pitossi, F. J. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-85 · Cited by 47 · cited 3×
“(2007) [19] have utilized a similar approach for determining Emax (which they refer to as the "intrinsic" amplification efficiency), although they concluded that a two-parametric sigmoid function was superior to the linear model upon which LRE is based.”
MethodEstimation of the reaction efficiency in polymerase chain reaction
Lalam, N. (2006) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2006.06.001 · Cited by 47 · cited 1×
“Attempts to model the entire amplification profile have included sigmoidal modeling using nonlinear regression [16-20], in addition to the application of various biochemical-based models [21-23], and other forms of mathematical modeling [24-26].”
MethodExpression genomics in breast cancer research: microarrays at the crossroads of biology and medicine
Miller, L. D., & Liu, E. T. (2007) · Breast Cancer Research · doi:10.1186/bcr1662 · Cited by 47 · cited 1×
“Founded upon the expectation that gene expression analysis can be used as a diagnostic tool to both predict and follow therapeutic outcomes [4,5], many studies have reported that effective diagnoses can be achieved with relatively small groups of biomarker transcripts, numbering between 10 and 100 [6,7], a range that…”
BackgroundRevisiting the sigmoidal curve fitting applied to quantitative real-time PCR data
Swillens, S., Dessars, B., & Housni, H. E. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.10.019 · Cited by 44 · cited 2×
“Unfortunately, effective implementation of SCF has been impeded by errors produced by distortions within the plateau phase, which can severely compromise the accuracy of SCF-based quantification [18,31-33].”
MethodInstant evaluation of the absolute initial number of cDNA copies from a single real-time PCR curve
Swillens, S. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh053 · Cited by 42 · cited 3×
“Finally, it should be noted that even though the principles of optical calibration described here have been developed using SYBR Green I, Swillens et al. (2004) describe an optical calibration methodology for hydrolysis probes that correlates fluorescence intensity to probe mass [34].”
BackgroundMethodInfluentialQiu, H., Durand, K., Rabinovitch-Chable, H., Rigaud, M., Gazaille, V., Clavère, P., & Sturtz, F. G. (2007) · BioTechniques · doi:10.2144/000112331 · Cited by 36 · cited 1×
“Demonstration that absolute quantification can be achieved by combining optical calibration with sigmoidal modeling (a method called "sigmoidal curve fitting" or SCF [18]) has led several groups to evaluate this approach as an alternative to standard curve-based quantification [27-33].”
MethodDetermination of Target Copy Number of Quantitative Standards Used in PCR-Based Diagnostic Assays
Wang, Z., & Spadoro, J. P. (1998) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-4164-5_3 · Cited by 34 · cited 2×
“A superbly effective solution has been provided by Wang and Spadoro [36], which exploits the single-molecule sensitivity inherent to PCR amplification.”
BackgroundMethodRelative quantification based on logistic models for individual polymerase chain reactions
Chervoneva, I., Li, Y., Iglewicz, B., Waldman, S. A., & Hyslop, T. (2007) · Statistics in Medicine · doi:10.1002/sim.3127 · Cited by 28 · cited 3×
“It should noted that Chervoneva et al. (2007) [20] have recently described modeling of real-time PCR using a logistic function identical to equation 7.”
MethodAbsolute estimation of initial concentrations of amplicon in a real-time RT-PCR process
Smith, M. V., Miller, C. R., Kohn, M. C., Walker, N. J., & Portier, C. J. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-409 · Cited by 27 · cited 1×
“Attempts to model the entire amplification profile have included sigmoidal modeling using nonlinear regression [16-20], in addition to the application of various biochemical-based models [21-23], and other forms of mathematical modeling [24-26].”
MethodTranslating Expression Profiling into a Clinically Feasible Test to Predict Neuroblastoma Outcome
Schramm, A. R., Vandesompele, J., Schulte, J. H., Dreesmann, S., Kaderali, L., Brors, B., Eils, R., Speleman, F., & Eggert, A. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-2032 · Cited by 27 · cited 1×
“Development of diagnostic assays for disease prediction could thus exploit the reduced technical complexity, speed of analysis, sensitivity and substantively greater resolution provided by real-time qPCR, as compared with microarray analysis [8].”
Roussel, Y., Harris, A. G., Lee, M. H., & Wilks, M. (2006) · Vaccine · doi:10.1016/j.vaccine.2006.07.013 · Cited by 26 · cited 1×
“Demonstration that absolute quantification can be achieved by combining optical calibration with sigmoidal modeling (a method called "sigmoidal curve fitting" or SCF [18]) has led several groups to evaluate this approach as an alternative to standard curve-based quantification [27-33].”
MethodDurtschi, J., Stevenson, J. B., Hymas, W. C., & Voelkerding, K. V. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.11.023 · Cited by 20 · cited 2×
“Unfortunately, effective implementation of SCF has been impeded by errors produced by distortions within the plateau phase, which can severely compromise the accuracy of SCF-based quantification [18,31-33].”
MethodLalam, N. (2007) · Statistical Applications in Genetics and Molecular Biology · doi:10.2202/1544-6115.1253 · Cited by 15 · cited 1×
“Attempts to model the entire amplification profile have included sigmoidal modeling using nonlinear regression [16-20], in addition to the application of various biochemical-based models [21-23], and other forms of mathematical modeling [24-26].”
MethodValidation and Estimation of Parameters for a General Probabilistic Model of the PCR Process
Saha, N., Watson, L. T., Kafadar, K., Ramakrishnan, N., Onufriev, A. V., Mane, S. P., & Vásquez-Robinet, C. (2007) · Journal of Computational Biology · doi:10.1089/cmb.2006.0123 · Cited by 4 · cited 1×
“Attempts to model the entire amplification profile have included sigmoidal modeling using nonlinear regression [16-20], in addition to the application of various biochemical-based models [21-23], and other forms of mathematical modeling [24-26].”
Method(2004) · PubMed Central
Cited by
Amplification efficiency: linking baseline and bias in the analysis of quantitative PCR data
Ruijter, J. M., Ramakers, C., Hoogaars, W. M. H., Karlen, Y., Bakker, O., van den Hoff, M. J. B., & Moorman, A. F. M. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp045 · Cited by 3,043
“Cycle-dependent changes in PCR efficiency are predicted by sigmoid models used in qPCR analysis (20,28,29).”
InfluentialSchmidt, G. W., & Delaney, S. K. (2010) · Molecular Genetics and Genomics · doi:10.1007/s00438-010-0511-1 · Cited by 553
Correlation Between Upstream Human Activities and Riverine Antibiotic Resistance Genes
Pruden, A., Arabi, M., & Storteboom, H. N. (2012) · Environmental Science & Technology · doi:10.1021/es302657r · Cited by 516
Why the need for qPCR publication guidelines?—The case for MIQE
Bustin, S. A. (2010) · Methods · doi:10.1016/j.ymeth.2009.12.006 · Cited by 375
Specific and sensitive quantitative RT-PCR of miRNAs with DNA primers
Balcells, I., Cirera, S., & Busk, P. K. (2011) · BMC Biotechnology · doi:10.1186/1472-6750-11-70 · Cited by 308
Metadata
- Authors
- Rutledge, R. G., & Stewart, D.
- Venue
- BMC Biotechnology
- Published
- 2008
- Volume
- 8
- Issue
- 1
- Pages
- 47
- ISSN
- 1472-6750 (ISSN-L)
- OpenAlex
- W2136524534
- Cited by
- 209
- References
- 40
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.