Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Statistical significance of quantitative PCR

Open access

Abstract

Background: PCR has the potential to detect and precisely quantify specific DNA sequences, but it is not yet often used as a fully quantitative method. A number of data collection and processing strategies have been described for the implementation of quantitative PCR. However, they can be experimentally cumbersome, their relative performances have not been evaluated systematically, and they often remain poorly validated statistically and/or experimentally. In this study, we evaluated the performance of known methods, and compared them with newly developed data processing strategies in terms of resolution, precision and robustness. Results: Our results indicate that simple methods that do not rely on the estimation of the efficiency of the PCR amplification may provide reproducible and sensitive data, but that they do not quantify DNA with precision. Other evaluated methods based on sigmoidal or exponential curve fitting were generally of both poor resolution and precision. A statistical analysis of the parameters that influence efficiency indicated that it depends mostly on the selected amplicon and to a lesser extent on the particular biological sample analyzed. Thus, we devised various strategies based on individual or averaged efficiency values, which were used to assess the regulated expression of several genes in response to a growth factor. Conclusion: Overall, qPCR data analysis methods differ significantly in their performance, and this analysis identifies methods that provide DNA quantification estimates of high precision, robustness and reliability. These methods allow reliable estimations of relative expression ratio of two-fold or higher, and our analysis provides an estimation of the number of biological samples that have to be analyzed to achieve a given precision.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2105-8-131

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Representations of real-time PCR amplification curves. The three phases of the amplification reaction are shown either on a linear scale (panel A) or on a semi-log scale (panel B). Panel A represents a typical amplification curve, while panel B depicts amplification curves generated from serial dilutions of the same sample, either undiluted or diluted 10- or 1000-fold (indicated as 1, 0.1 or 0.001, respectively). During the lag phase (phase I), the fluorescence resulting from DNA amplification is undetectable above noise fluorescence in part A, while in part B, some data points take negative values and are not represented. This phase is used to evaluate the baseline "noise" of the PCR amplification. Exponential amplification of the DNA is detected in phase II (cycles 16 to 23, panel A). This phase of the amplification corresponds to the linear portion of the curve in panel B (closed circles). A threshold value is usually set by the user to cross the log linear portion of the curve, defining the threshold cycle value (Ct). Phase II is followed by a linear or plateau phase as reactants become exhausted (phase III). The inserted equations describe the dynamic of the amplification during phase II.
Figure 1 Representations of real-time PCR amplification curves. The three phases of the amplification reaction are shown either on a linear scale (panel A) or on a semi-log scale (panel B). Panel A represents a typical amplification curve, while panel B depicts amplification curves generated from serial dilutions of the same sample, either undiluted or diluted 10- or 1000-fold (indicated as 1, 0.1 or 0.001, respectively). During the lag phase (phase I), the fluorescence resulting from DNA amplification is undetectable above noise fluorescence in part A, while in part B, some data points take negative values and are not represented. This phase is used to evaluate the baseline "noise" of the PCR amplification. Exponential amplification of the DNA is detected in phase II (cycles 16 to 23, panel A). This phase of the amplification corresponds to the linear portion of the curve in panel B (closed circles). A threshold value is usually set by the user to cross the log linear portion of the curve, defining the threshold cycle value (Ct). Phase II is followed by a linear or plateau phase as reactants become exhausted (phase III). The inserted equations describe the dynamic of the amplification during phase II.CC BY · PubMed Central
Figure 2 Measurement of the efficiency of a PCR reaction. A: Estimation of the efficiency using the Serial dilution (SerDil) method. Five dilutions of a cDNA sample were amplified using the fibronectin (FN) amplicon. Each dilution was analyzed with five replicates PCR reactions and each data point represents one Ct value determined as in Figure 1B. Linear regression parameters and calculation of the efficiency value are shown in the inserted textbox. B: Screenshot of the LinReg PCR program analysis window, which allows the estimation of the efficiency value from each set of amplification curves [13]. Data correspond to one of the reactions performed from the undiluted sample used in part A. C: Comparison of the efficiency values obtained using the Serial dilution and LinReg methods for the FN amplicon. Efficiency values were determined from four independent cDNA samples using the Serial Dilution method as in part A, or the LinReg method as in part B. For each sample, efficiency value were either determined from one linear regression performed on 24 reactions altogether (Serdil) and error bars calculated from the standard deviation on the slope as determined from the linear regression method or the individual efficiency values determined from each of the same 24 PCR reactions (LinReg) were averaged, and error bars represent the standard deviation on the set of values.
Figure 2 Measurement of the efficiency of a PCR reaction. A: Estimation of the efficiency using the Serial dilution (SerDil) method. Five dilutions of a cDNA sample were amplified using the fibronectin (FN) amplicon. Each dilution was analyzed with five replicates PCR reactions and each data point represents one Ct value determined as in Figure 1B. Linear regression parameters and calculation of the efficiency value are shown in the inserted textbox. B: Screenshot of the LinReg PCR program analysis window, which allows the estimation of the efficiency value from each set of amplification curves [13]. Data correspond to one of the reactions performed from the undiluted sample used in part A. C: Comparison of the efficiency values obtained using the Serial dilution and LinReg methods for the FN amplicon. Efficiency values were determined from four independent cDNA samples using the Serial Dilution method as in part A, or the LinReg method as in part B. For each sample, efficiency value were either determined from one linear regression performed on 24 reactions altogether (Serdil) and error bars calculated from the standard deviation on the slope as determined from the linear regression method or the individual efficiency values determined from each of the same 24 PCR reactions (LinReg) were averaged, and error bars represent the standard deviation on the set of values.CC BY · PubMed Central
Figure 3 Distribution of efficiency values in the complete data set. Efficiency of 704 PCR reactions encompassing different cDNA samples, primers and dilutions are shown as determined using the LinReg method, as done in Figure 2B.
Figure 3 Distribution of efficiency values in the complete data set. Efficiency of 704 PCR reactions encompassing different cDNA samples, primers and dilutions are shown as determined using the LinReg method, as done in Figure 2B.CC BY · PubMed Central
Figure 4 Comparison of the different calculation models when applied to samples of known relative concentrations. Each cDNA samples serial dilutions were processed with the indicated models, measured concentration were expressed as relative to the undiluted sample. Then results of all amplicons were averaged for a given model.
Figure 4 Comparison of the different calculation models when applied to samples of known relative concentrations. Each cDNA samples serial dilutions were processed with the indicated models, measured concentration were expressed as relative to the undiluted sample. Then results of all amplicons were averaged for a given model.CC BY · PubMed Central
Figure 5 Comparison of the (SavrgE)Ct, (PavrgE)Ct and ΔCt methods to quantify gene expression regulation. cDNAs were prepared from RNA extracted from fibroblastic cells induced or not by TGF-β treatment, as described in the Materials and methods. Expression as determined from the mRNA levels of the plasminogen activator inhibitor 1 (PAI-1), fibronectin (FN) and connective tissue growth factor (CTGF) genes were normalized to those of the ribosomal L27 protein, used as an invariant internal reference. Normalized gene expression was calculated using the (SavrgE)Ct, (PavrgE)Ct or the ΔCt methods, as indicated, using either the complete set of 10 replicate assays (top histograms), or using just three measurements (first three assays of the series, bottom histograms). Error bars represent standard deviations on the normalized ratio. A t-test was performed on the normalized gene expression to check whether the expression were statistically different between the induced and the non-induced state (* = p < 0.05, ** = p < 0.001, # = p > 0.1).
Figure 5 Comparison of the (SavrgE)Ct, (PavrgE)Ct and ΔCt methods to quantify gene expression regulation. cDNAs were prepared from RNA extracted from fibroblastic cells induced or not by TGF-β treatment, as described in the Materials and methods. Expression as determined from the mRNA levels of the plasminogen activator inhibitor 1 (PAI-1), fibronectin (FN) and connective tissue growth factor (CTGF) genes were normalized to those of the ribosomal L27 protein, used as an invariant internal reference. Normalized gene expression was calculated using the (SavrgE)Ct, (PavrgE)Ct or the ΔCt methods, as indicated, using either the complete set of 10 replicate assays (top histograms), or using just three measurements (first three assays of the series, bottom histograms). Error bars represent standard deviations on the normalized ratio. A t-test was performed on the normalized gene expression to check whether the expression were statistically different between the induced and the non-induced state (* = p < 0.05, ** = p < 0.001, # = p > 0.1).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Research works printed but not linked: 2

  1. Livak KJ: ABI Prism 7700 sequence detection system. User Bulletin 2. P E Applied Biosystems. 1997
  2. Rosner B: Fundamentals in biostatistics. 2000, Duxbury ed., 518-520. 5th edit.

Cited by

See all 373

Metadata

Authors
Karlen, Y., McNair, A., Perseguers, S., Mazza, C., & Mermod, N.
Affiliations
  • University of Lausanne (CH)
  • Max Planck Institute of Quantum Optics (DE)
  • University of Fribourg (CH)
Corresponding author
Mermod, Nicolas
Venue
BMC Bioinformatics
Published
2007-04-20
Volume
8
Issue
1
Pages
131-131
ISSN
1471-2105 (ISSN-L)
OpenAlex
W2073857965
Cited by
373
References
39
Citations by year
2026: 11 · 2025: 9 · 2024: 15 · 2023: 19 · 2022: 16 · 2021: 24 · 2020: 16 · 2019: 12 · 2018: 13 · 2017: 20 · 2016: 20 · 2015: 21 · 2014: 26 · 2013: 30 · 2012: 24
FWCI
8.65
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • BMC Bioinformatics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • reroDoc Digital Library (submittedVersion)
  • IRIS (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Max Planck Institute for Plasma Physics (submittedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion)
  • SERVAL (Université de Lausanne) (submittedVersion, other-oa)
Funders
  • National Science Foundation
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
Keywords
real-time PCR, qPCR data analysis, PCR efficiency, efficiency estimation, sigmoidal curve fitting, exponential fitting, relative gene expression, statistical power
MeSH terms
Base Sequence, Gene Expression Regulation, Polymerase Chain Reaction, Sequence Analysis, DNA

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Statistical significance of quantitative PCR. https://app.cochat.ai/papers/10.1186/1471-2105-8-131
The paper
Karlen, Y., McNair, A., Perseguers, S., Mazza, C., & Mermod, N. (2007). Statistical significance of quantitative PCR. BMC Bioinformatics. https://doi.org/10.1186/1471-2105-8-131

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.