High-frequency irreversible electroporation (H-FIRE) for non-thermal ablation without muscle contraction
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Background: Therapeutic irreversible electroporation (IRE) is an emerging technology for the non-thermal ablation of tumors. The technique involves delivering a series of unipolar electric pulses to permanently destabilize the plasma membrane of cancer cells through an increase in transmembrane potential, which leads to the development of a tissue lesion. Clinically, IRE requires the administration of paralytic agents to prevent muscle contractions during treatment that are associated with the delivery of electric pulses. This study shows that by applying high-frequency, bipolar bursts, muscle contractions can be eliminated during IRE without compromising the non-thermal mechanism of cell death. Methods: A combination of analytical, numerical, and experimental techniques were performed to investigate high-frequency irreversible electroporation (H-FIRE). A theoretical model for determining transmembrane potential in response to arbitrary electric fields was used to identify optimal burst frequencies and amplitudes for in vivo treatments. A finite element model for predicting thermal damage based on the electric field distribution was used to design non-thermal protocols for in vivo experiments. H-FIRE was applied to the brain of rats, and muscle contractions were quantified via accelerometers placed at the cervicothoracic junction. MRI and histological evaluation was performed post-operatively to assess ablation. Results: No visual or tactile evidence of muscle contraction was seen during H-FIRE at 250 kHz or 500 kHz, while all IRE protocols resulted in detectable muscle contractions at the cervicothoracic junction. H-FIRE produced ablative lesions in brain tissue that were characteristic in cellular morphology of non-thermal IRE treatments. Specifically, there was complete uniformity of tissue death within targeted areas, and a sharp transition zone was present between lesioned and normal brain. Conclusions: H-FIRE is a feasible technique for non-thermal tissue ablation that eliminates muscle contractions seen in IRE treatments performed with unipolar electric pulses. Therefore, it has the potential to be performed clinically without the administration of paralytic agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies.
Gabriel, C. (1996) · doi:10.21236/ada303903 · Cited by 2,097
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Theory of electroporation: A review
Weaver, J. C., & Chizmadzhev, Y. A. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(96)05062-3 · Cited by 1,599
Tissue Ablation with Irreversible Electroporation
Davalos, R. V., Mir, L. M., & Rubinsky, B. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8981-8 · Cited by 1,293
Self-citationPrinciples of and Advances in Percutaneous Ablation
Ahmed, M., Brace, C. L., Lee, F. T., & Goldberg, S. N. (2011) · Radiology · doi:10.1148/radiol.10081634 · Cited by 916
Plasma membrane phosphoinositide organization by protein electrostatics
McLaughlin, S., & Murray, D. (2005) · Nature · doi:10.1038/nature04398 · Cited by 868 · cited 1×
“dne 5 × 10 -9 set equal to [55] Arena et al.”
BackgroundPhase I trial of interleukin-12 plasmid electroporation in patients with metastatic melanoma
Daud, A. I., DeConti, R. C., Andrews, S., Urbas, P., Riker, A. I., Sondak, V. K., Munster, P. N., Sullivan, D. M., Ugen, K. E., Messina, J. L., et al. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.15.6794 · Cited by 701
Nanosecond pulsed electric fields cause melanomas to self-destruct
Nuccitelli, R., Pliquett, U., Chen, X., Ford, W., James Swanson, R., Beebe, S. J., Kolb, J. F., & Schoenbach, K. H. (2006) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2006.02.181 · Cited by 512
In Vivo Results of a New Focal Tissue Ablation Technique: Irreversible Electroporation
Edd, J. F., Horowitz, L., Davalos, R. V., Mir, L. M., & Rubinsky, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873745 · Cited by 510
Self-citationModeling Electroporation in a Single Cell
Krassowska, W., & Filev, P. D. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.094235 · Cited by 501
Tumor Ablation with Irreversible Electroporation
Al-Sakere, B., André, F., Bernat, C., Connault, E., Opolon, P., Davalos, R. V., Rubinsky, B., & Mir, L. M. (2007) · PLoS ONE · doi:10.1371/journal.pone.0001135 · Cited by 490
Self-citationInvestigation of the Safety of Irreversible Electroporation in Humans
Thomson, K. R., Cheung, W., Ellis, S. J., Federman, D., Kavnoudias, H., Loader-Oliver, D., Roberts, S., Evans, P., Ball, C., & Haydon, A. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2010.12.014 · Cited by 466
Irreversible Electroporation in Medicine
Rubinsky, B. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600401 · Cited by 415
The Effect of Irreversible Electroporation on Blood Vessels
Maor, E., Ivorra, A., Leor, J., & Rubinsky, B. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600407 · Cited by 370
Miklavčič, D., Šemrov, D., Mekid, H., & Mir, L. M. (2000) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/s0304-4165(00)00101-x · Cited by 366
Therapeutic perspectives of in vivo cell electropermeabilization
Mir, L. M. (2001) · Bioelectrochemistry · doi:10.1016/s0302-4598(00)00112-4 · Cited by 344
Kotnik, T., & Miklavčič, D. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.070771 · Cited by 318 · cited 7×
“Kotnik T, Miklavcic D: Theoretical evaluation of voltage inducement on internal membranes of biological cells exposed to electric fields.”
BackgroundInfluentialPakhomov, A. G., Kolb, J. F., White, J. A., Joshi, R. P., Xiao, S., & Schoenbach, K. H. (2007) · Bioelectromagnetics · doi:10.1002/bem.20354 · Cited by 292
Diverse Effects of Nanosecond Pulsed Electric Fields on Cells and Tissues
Beebe, S. J., White, J., Blackmore, P. F., Deng, Y., Somers, K., & Schoenbach, K. H. (2003) · DNA and Cell Biology · doi:10.1089/104454903322624993 · Cited by 250
Irreversible Electroporation: A New Challenge in “Out of Operating Theater” Anesthesia
Ball, C., Thomson, K. R., & Kavnoudias, H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181d27b30 · Cited by 246
Advanced Electroporation Techniques in Biology and Medicine
Pakhomov, A. G., Miklavcic, D., & Markov, M. S. (2010) · CRC Press eBooks · doi:10.1201/ebk1439819067 · Cited by 232
Dielectric Properties of Aqueous NaCl Solutions at Microwave Frequencies
Nörtemann, K., Hilland, J., & Kaatze, U. (1997) · The Journal of Physical Chemistry A · doi:10.1021/jp971623a · Cited by 221
Mathematical Modeling of Irreversible Electroporation for Treatment Planning
Edd, J. F., & Davalos, R. V. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600403 · Cited by 196
Self-citationSensory Effects of Transient Electrical Stimulation - Evaluation with a Neuroelectric Model
Reilly, J. P., Freeman, V. T., & Larkin, W. D. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325509 · Cited by 195
Tekle, E., Astumian, R. D., & Chock, P. B. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.10.4230 · Cited by 192
The Effects of Irreversible Electroporation (IRE) on Nerves
Li, W., Fan, Q., Ji, Z., Qiu, X., & Li, Z. (2011) · PLoS ONE · doi:10.1371/journal.pone.0018831 · Cited by 182
Role of pulse shape in cell membrane electropermeabilization
Kotnik, T., Pucihar, G., Reberšek, M., Miklavčič, D., & Mir, L. M. (2003) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(03)00173-1 · Cited by 166
Non Thermal Irreversible Electroporation: Novel Technology for Vascular Smooth Muscle Cells Ablation
Maor, E., Ivorra, A., & Rubinsky, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004757 · Cited by 162
Intracranial Nonthermal Irreversible Electroporation: In Vivo Analysis
Garcia, P. A., Rossmeisl, J. H., Neal, R. E., Ellis, T. L., Olson, J. D., Henao-Guerrero, N., Robertson, J., & Davalos, R. V. (2010) · The Journal of Membrane Biology · doi:10.1007/s00232-010-9284-z · Cited by 162
Self-citationCell membrane electropermeabilization by symmetrical bipolar rectangular pulses
Kotnik, T., Mir, L. M., Flisar, K., Puc, M., & Miklavčič, D. (2001) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00114-1 · Cited by 159
The response of the myelinated nerve fiber to short duration biphasic stimulating currents
van den Honert, C., & Mortimer, J. T. (1979) · Annals of Biomedical Engineering · doi:10.1007/bf02363130 · Cited by 152
Cell membrane electropermeabilization by symmetrical bipolar rectangular pulses
Kotnik, T., Miklavčič, D., & Mir, L. M. (2001) · Bioelectrochemistry · doi:10.1016/s1567-5394(01)00115-3 · Cited by 149
Temperature considerations during irreversible electroporation
Davalos, R. V., & Rubinsky, B. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.04.046 · Cited by 148
Self-citationModeling Electroporation in a Single Cell. II. Effects of Ionic Concentrations
DeBruin, K. A., & Krassowska, W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76974-2 · Cited by 147
Garcia, P. A., Pancotto, T., Rossmeisl, J. H., Henao-Guerrero, N., Gustafson, N. R., Daniel, G. B., Robertson, J. L., Ellis, T. L., & Davalos, R. V. (2011) · Technology in Cancer Research & Treatment · doi:10.7785/tcrt.2012.500181 · Cited by 146
Self-citationTheoretical Considerations of Tissue Electroporation With High-Frequency Bipolar Pulses
Arena, C. B., Sano, M. B., Rylander, M. N., & Davalos, R. V. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102021 · Cited by 139
Self-citationDavey, G. E., Murmann, P., & Heizmann, C. W. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m103541200 · Cited by 137
Gascoyne, P. R. C., Pethig, R., Burt, J. P. H., & Becker, F. F. (1993) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(93)90032-u · Cited by 114
Ellis, T. L., Garcia, P. A., Rossmeisl, J. H., Henao-Guerrero, N., Robertson, J. L., & Davalos, R. V. (2010) · Journal of neurosurgery · doi:10.3171/2010.5.jns091448 · Cited by 112
Self-citationPreclinical Validation of Electrochemotherapy as an Effective Treatment for Brain Tumors
Agerholm-Larsen, B., Iversen, H. K., Ibsen, P. H., Møller, J. M., Mahmood, F., Jensen, K. S., & Gehl, J. (2011) · Cancer Research · doi:10.1158/0008-5472.can-11-0451 · Cited by 110
Harris, C., & Kell, D. B. (1983) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(83)85097-1 · Cited by 66
Harris, C., & Kell, D. B. (1983) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(83)80648-2 · Cited by 44
Yao, C., Mo, D., Li, C., Sun, C., & Mi, Y. (2007) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2007.905110 · Cited by 31
Cited by
Electroporation-Based Technologies for Medicine: Principles, Applications, and Challenges
Yarmush, M. L., Golberg, A., Serša, G., Kotnik, T., & Miklavčič, D. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104622 · Cited by 889
Cell death due to electroporation – A review
Batista Napotnik, T., Polajžer, T., & Miklavčič, D. (2021) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2021.107871 · Cited by 542
A Review of Basic to Clinical Studies of Irreversible Electroporation Therapy
Jiang, C., Davalos, R. V., & Bischof, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2367543 · Cited by 332
Self-citationNonthermal Irreversible Electroporation: Fundamentals, Applications, and Challenges
Golberg, A., & Yarmush, M. L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2238672 · Cited by 198
“An additional challenge is to eliminate NTIRE induced muscle contraction without using total body muscle paralyzes agents [71], [91].”
BackgroundIrreversible electroporation (NanoKnife) in cancer treatment
Jourabchi, N., Beroukhim, K., Tafti, B. A., Kee, S. T., & Lee, E. W. (2014) · Gastrointestinal Intervention · doi:10.1016/j.gii.2014.02.002 · Cited by 99
Metadata
- Authors
- Arena, C. B., Sano, M. B., Rossmeisl, J. H., Caldwell, J. L., Garcia, P. A., Rylander, M. N., & Davalos, R. V.
- Venue
- BioMedical Engineering OnLine
- Published
- 2011-11-21
- Volume
- 10
- Issue
- 1
- Pages
- 102-102
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2046449631
- Cited by
- 361
- References
- 43
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.