Antimicrobial titanium/silver PVD coatings on titanium
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Background: Biofilm formation and deep infection of endoprostheses is a recurrent complication in implant surgery. Post-operative infections may be overcome by adjusting antimicrobial properties of the implant surface prior to implantation. In this work we described the development of an antimicrobial titanium/silver hard coating via the physical vapor deposition (PVD) process. Methods: Coatings with a thickness of approximately 2 μm were deposited on titanium surfaces by simultaneous vaporisation of both metals in an inert argon atmosphere with a silver content of approximately 0.7 – 9% as indicated by energy dispersive X-ray analysis. On these surfaces microorganisms and eukaryotic culture cells were grown. Results: The coatings released sufficient silver ions (0.5–2.3 ppb) when immersed in PBS and showed significant antimicrobial potency against Staphylococcus epidermis and Klebsiella pneumoniae strains. At the same time, no cytotoxic effects of the coatings on osteoblast and epithelial cells were found. Conclusion: Due to similar mechanical performance when compared to pure titanium, the TiAg coatings should be suitable to provide antimicrobial activity on load-bearing implant surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2016) · Alloy Phase Diagrams · doi:10.31399/asm.hb.v03.a0006247 · Cited by 16,046
Bacterial biofilms: from the Natural environment to infectious diseases
Hall-Stoodley, L., Costerton, J. W., & Stoodley, P. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro821 · Cited by 7,143
Biofilms as Complex Differentiated Communities
Stoodley, P., Sauer, K., Davies, D. G., & Costerton, J. W. (2002) · Annual Review of Microbiology · doi:10.1146/annurev.micro.56.012302.160705 · Cited by 3,158
Biomaterial-Centered Infection: Microbial Adhesion Versus Tissue Integration
Gristina, A. G. (1987) · Science · doi:10.1126/science.3629258 · Cited by 2,156
Lew, D. P., & Waldvogel, F. A. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16727-5 · Cited by 1,883
Survival strategies of infectious biofilms
Fux, C. A., Costerton, J. W., Stewart, P. S., & Stoodley, P. (2005) · Trends in Microbiology · doi:10.1016/j.tim.2004.11.010 · Cited by 1,812
Bacterial silver resistance: molecular biology and uses and misuses of silver compounds
Silver, S. (2003) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(03)00047-0 · Cited by 1,312 · cited 2×
“Although plasmid derived resistance in microorganisms living in halide containing environments has been described, up to now only few cases of silver resistant bacteria were found in hospital [14].”
Background7 Antimicrobial Activity and Action of Silver
Russell, A. D., & Hugo, W. B. (1994) · Progress in Medicinal Chemistry · doi:10.1016/s0079-6468(08)70024-9 · Cited by 1,033
Silver ion release from antimicrobial polyamide/silver composites
Kumar, R., & Münstedt, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.030 · Cited by 739
Silver coated materials for external fixation devices: in vitro biocompatibility and genotoxicity
Bosetti, M., Massè, A., Tobin, E., & Cannas, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00198-3 · Cited by 557
Cited by
A review of the biomaterials technologies for infection-resistant surfaces
Campoccia, D., Montanaro, L., & Arciola, C. R. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.089 · Cited by 1,358
Review of titanium surface modification techniques and coatings for antibacterial applications
Chouirfa, H., Bouloussa, H., Migonney, V., & Falentin-Daudré, C. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.10.036 · Cited by 1,031
Antibacterial coatings on titanium implants
Zhao, L., Chu, P. K., Zhang, Y., & Wu, Z. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31463 · Cited by 866
The future of biologic coatings for orthopaedic implants
Goodman, S. B., Yao, Z., Keeney, M., & Yang, F. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.074 · Cited by 779
Chen, W., Liu, Y., Courtney, H. S., Bettenga, M., Agrawal, C. M., Bumgardner, J. D., & Ong, J. L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.07.003 · Cited by 594
Zhang, L.-C., Chen, L.-Y., & Wang, L. (2020) · Advanced Engineering Materials · doi:10.1002/adem.201901258 · Cited by 456
Kazemzadeh-Narbat, M., Kindrachuk, J., Duan, K., Jenssen, H., Hancock, R. E. W., & Wang, R. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.035 · Cited by 343
Biomaterial and antibiotic strategies for peri‐implantitis: A review
Norowski, P. A., & Bumgardner, J. D. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31152 · Cited by 339
Bioinspired surface modification of orthopedic implants for bone tissue engineering
Hu, C., Ashok, D., Nisbet, D. R., & Gautam, V. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119366 · Cited by 324
Antifouling and antimicrobial biomaterials: an overview
Francolini, I., Vuotto, C., Piozzi, A., & Donelli, G. (2017) · APMIS · doi:10.1111/apm.12675 · Cited by 322
Quinn, J., McFadden, R., Chan, C.-W., & Carson, L. (2020) · iScience · doi:10.1016/j.isci.2020.101745 · Cited by 285
Porous Titanium Implants: A Review
Pałka, K., & Pokrowiecki, R. (2018) · Advanced Engineering Materials · doi:10.1002/adem.201700648 · Cited by 279
Metal‐based antimicrobial strategies
Turner, R. J. (2017) · Microbial Biotechnology · doi:10.1111/1751-7915.12785 · Cited by 202
“Combination coatings produced through the deposition of Ag and Ti have also demonstrated decreased cell viability against Staphylococcus aureus and Klebsiella pneumoniae, while displaying no cytotoxicity to epithelial and osteoblast cells (Ewald et al., 2006).”
BackgroundPrevention of pin tract infection with titanium‐copper alloys
Shirai, T., Tsuchiya, H., Shimizu, T., Ohtani, K., Zen, Y., & Tomita, K. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31412 · Cited by 199
“Previous studies on conferring antibacterial properties to biomaterials have relied on surface functionalization techniques such as covalently attaching polycationic groups,(13) impregnating or loading chitosan nanoparticles with antimicrobial agents,(14,15) and coating implant surfaces with either quaternary ammonium…”
BackgroundInnovative antimicrobial coating of titanium implants with iodine
Tsuchiya, H., Shirai, T., Nishida, H., Murakami, H., Kabata, T., Yamamoto, N., Watanabe, K., & Nakase, J. (2012) · Journal of Orthopaedic Science · doi:10.1007/s00776-012-0247-3 · Cited by 197
“In order to reduce the incidence of implant-associated infections, several biomaterial surface treatments have been proposed [5–13].”
BackgroundGuo, S., Lu, Y., Wu, S., Liu, L., He, M., Zhao, C., Gan, Y., Lin, J., Luo, J., Xu, X., et al. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.11.126 · Cited by 163
Metadata
- Authors
- Ewald, A., Glückermann, S. K., Thull, R., & Gbureck, U.
- Venue
- BioMedical Engineering OnLine
- Published
- 2006-03-24
- Volume
- 5
- Issue
- 1
- Pages
- 22-22
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W1919188446
- Cited by
- 281
- References
- 27
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.