Atrial fibrillation detection by heart rate variability in Poincare plot
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background: Atrial fibrillation (AFib) is one of the prominent causes of stroke, and its risk increases with age. We need to detect AFib correctly as early as possible to avoid medical disaster because it is likely to proceed into a more serious form in short time. If we can make a portable AFib monitoring system, it will be helpful to many old people because we cannot predict when a patient will have a spasm of AFib. Methods: We analyzed heart beat variability from inter-beat intervals obtained by a wavelet-based detector. We made a Poincare plot using the inter-beat intervals. By analyzing the plot, we extracted three feature measures characterizing AFib and non-AFib: the number of clusters, mean stepping increment of inter-beat intervals, and dispersion of the points around a diagonal line in the plot. We divided distribution of the number of clusters into two and calculated mean value of the lower part by k-means clustering method. We classified data whose number of clusters is more than one and less than this mean value as non-AFib data. In the other case, we tried to discriminate AFib from non-AFib using support vector machine with the other feature measures: the mean stepping increment and dispersion of the points in the Poincare plot. Results: We found that Poincare plot from non-AFib data showed some pattern, while the plot from AFib data showed irregularly irregular shape. In case of non-AFib data, the definite pattern in the plot manifested itself with some limited number of clusters or closely packed one cluster. In case of AFib data, the number of clusters in the plot was one or too many. We evaluated the accuracy using leave-one-out cross-validation. Mean sensitivity and mean specificity were 91.4% and 92.9% respectively. Conclusions: Because pulse beats of ventricles are less likely to be influenced by baseline wandering and noise, we used the inter-beat intervals to diagnose AFib. We visually displayed regularity of the inter-beat intervals by way of Poincare plot. We tried to design an automated algorithm which did not require any human intervention and any specific threshold, and could be installed in a portable AFib monitoring system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Chung, F. (1996) · CBMS Regional Conference Series in Mathematics · doi:10.1090/cbms/092 · Cited by 5,524
Prevalence of atrial fibrillation in elderly subjects (the Cardiovascular Health Study)
Furberg, C. D., Psaty, B. M., Manolio, T. A., Gardin, J. M., Smith, V. E., & Rautaharju, P. M. (1994) · The American Journal of Cardiology · doi:10.1016/0002-9149(94)90363-8 · Cited by 1,096
Konings, K. T. S., Smeets, J. L. R. M., Penn, O. C., Wellens, H. J. J., & Allessie, M. A. (1997) · Circulation · doi:10.1161/01.cir.95.5.1231 · Cited by 452 · cited 1×
“Slow conduction shortens wavelengths of the wandering electricity signals; thus, this area of slow conduction increases the number of re-current wave fronts of depolarization in atria and contributes to the sustaining of AFib [5].”
Background(2009) · IFMBE Proceedings · doi:10.1007/978-3-540-89208-3 · Cited by 204
Mant, J., Fitzmaurice, D. A., Hobbs, F. D. R., Jowett, S., Murray, E. T., Holder, R., Davies, M., & Lip, G. Y. H. (2007) · BMJ · doi:10.1136/bmj.39227.551713.ae · Cited by 166
Clinical features of paroxysmal atrial fibrillation an observation of 94 patients.
TAKAHASHI, N., SEKI, A., IMATAKA, K., & FUJII, J. (1981) · Japanese Heart Journal · doi:10.1536/ihj.22.143 · Cited by 124
Sudlow, M., Rodgers, H., Kenny, R. A., & Thomson, R. (1998) · BMJ · doi:10.1136/bmj.317.7154.327 · Cited by 77 · cited 1×
“Sensitivity and specificity using pulse palpation were (93%, 71%) in case of women elder than 75, (100%, 86%) in case of 65-74 aged women, (95%, 71%) in case of men elder than 75, (100%, 79%) in case of 65-74 aged men, (sensitivity, specificity) respectively [7].”
MethodAnalysis of electrocardiograms during atrial fibrillation
Jacquemet, V., van Oosterom, A., Vesin, J.-M., & Kappenberger, L. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/emb-m.2006.250511 · Cited by 61
Electrocardiology of atrial fibrillation
Bollmann, A., & Lombardi, F. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/emb-m.2006.250504 · Cited by 59
Cited by
Xiong, Z., Nash, M. P., Cheng, E., Fedorov, V. V., Stiles, M. K., & Zhao, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad9ed · Cited by 161
“…et al 2016), whereas ventricular-activity-based analyses look for irregularity in the RR intervals of QRS complexes (Tateno and Glass 2001, Sarkar et al 2008, Park et al 2009, Alcaraz et al 2010, Lake and Moorman 2010, Huang et al 2011, DeMazumder et al 2013, Carrara et al 2015, Linker 2016).”
BackgroundDetection of Atrial Fibrillation in ECG Hand-held Devices Using a Random Forest Classifier
Zabihi, M., Bahrami Rad, A., Katsaggelos, A. K., Kiranyaz, S., Narkilahti, S., & Gabbouj, M. (2017) · Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2017.069-336 · Cited by 158
“[16].”
Metadata
- Authors
- Park, J., Lee, S., & Jeon, M.
- Venue
- BioMedical Engineering OnLine
- Published
- 2009-12
- Volume
- 8
- Issue
- 1
- Pages
- 38-38
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2027774888
- Cited by
- 167
- References
- 17
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atrial fibrillation detection by heart rate variability in Poincare plot. https://app.cochat.ai/papers/10.1186/1475-925x-8-38
- The paper
- Park, J., Lee, S., & Jeon, M. (2009). Atrial fibrillation detection by heart rate variability in Poincare plot. BioMedical Engineering OnLine. https://doi.org/10.1186/1475-925x-8-38
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.