Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Left atrial longitudinal strain by speckle tracking echocardiography correlates well with left ventricular filling pressures in patients with heart failure

Open access
Cameli, Matteo, Lisi, Matteo, Mondillo, Sergio, Padeletti, Margherita, Ballo, Piercarlo, Tsioulpas, Charilaos, Bernazzali, Sonia, Maccherini, Massimo·2010·Cardiovascular Ultrasound

Abstract

BACKGROUND: The combination of early transmitral inflow velocity and mitral annular tissue Doppler imaging (E/Em ratio) is widely applied to noninvasively estimate left ventricular (LV) filling pressures. However E/Em ratio has a significant gray zone and its accuracy in patients with heart failure is debated. Left atrial (LA) deformation analysis by speckle tracking echocardiography (STE) was recently proposed as an alternative approach to estimate LV filling pressures. This study aimed at exploring the correlation of LA longitudinal function by STE and Doppler measurements with direct measurements of LV filling pressures in patients with heart failure. METHODS: A total of 36 patients with advanced systolic heart failure (ejection fraction < or = 35%), undergoing right heart catheterization, were studied. Simultaneously to pulmonary capillary wedge pressure (PCWP) determination, peak atrial longitudinal strain (PALS) and mean E/Em ratio were measured in all subjects by two independent operators. PALS values were obtained by averaging all segments (global PALS), and by separately averaging segments measured in the 4-chamber and 2-chamber views. RESULTS: Not significant correlation was found between mean E/Em ratio and PCWP (R = 0.15). A close negative correlation between global PALS and the PCWP was found (R = -0.81, p < 0.0001). Furthermore, global PALS demonstrated the highest diagnostic accuracy (AUC of 0.93) and excellent sensitivity and specificity of 100% and 93%, respectively, to predict elevated filling pressure using a cutoff value less than 15.1%. Bland-Altman analysis confirmed this close agreement between PCWP estimated by global PALS and invasive PCWP (mean bias 0.1 +/- 8.0 mmHg). CONCLUSION: In a group of patients with advanced systolic heart failure, E/Em ratio correlated poorly with invasively obtained LV filling pressures. However, LA longitudinal deformation analysis by STE correlated well with PCWP, providing a better estimation of LV filling pressures in this particular clinical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1476-7120-8-14

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 274

Metadata

Authors
Cameli, M., Lisi, M., Mondillo, S., Padeletti, M., Ballo, P., Tsioulpas, C., Bernazzali, S., & Maccherini, M.
Venue
Cardiovascular Ultrasound
Published
2010-04-21
Volume
8
Issue
1
Pages
14-14
ISSN
1476-7120 (ISSN-L)
OpenAlex
W2127386115
Cited by
274
References
30
FWCI
6.34
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left atrial longitudinal strain by speckle tracking echocardiography correlates well with left ventricular filling pressures in patients with heart failure. https://app.cochat.ai/papers/10.1186/1476-7120-8-14
The paper
Cameli, M., Lisi, M., Mondillo, S., Padeletti, M., Ballo, P., Tsioulpas, C., Bernazzali, S., & Maccherini, M. (2010). Left atrial longitudinal strain by speckle tracking echocardiography correlates well with left ventricular filling pressures in patients with heart failure. Cardiovascular Ultrasound. https://doi.org/10.1186/1476-7120-8-14

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.