Magnetic resonance angiography: current status and future directions
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
With recent improvement in hardware and software techniques, magnetic resonance angiography (MRA) has undergone significant changes in technique and approach. The advent of 3.0 T magnets has allowed reduction in exogenous contrast dose without compromising overall image quality. The use of novel intravascular contrast agents substantially increases the image windows and decreases contrast dose. Additionally, the lower risk and cost in non-contrast enhanced (NCE) MRA has sparked renewed interest in these methods. This article discusses the current state of both contrast-enhanced (CE) and NCE-MRA. New CE-MRA methods take advantage of dose reduction at 3.0 T, novel contrast agents, and parallel imaging methods. The risks of gadolinium-based contrast media, and the NCE-MRA methods of time-of-flight, steady-state free precession, and phase contrast are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748 · cited 1×
“Clinical applications for Magnetic Resonance Angiography (MRA) are rapidly expanding as technological advances in both hardware and imaging techniques overcome previous limitations, and the risks from intravenous contrast agents and repeated ionizing radiation exposure become more salient for the clinician and patient…”
BackgroundCornier, M.-A., Dabelea, D., Hernandez, T. L., Lindstrom, R. C., Steig, A. J., Stob, N. R., Van Pelt, R. E., Wang, H., & Eckel, R. H. (2008) · Endocrine Reviews · doi:10.1210/er.2008-0024 · Cited by 2,162
Images in Cardiovascular Medicine
(2012) · Wilderness & Environmental Medicine · doi:10.1016/j.wem.2012.05.013 · Cited by 1,519
Nephrogenic Systemic Fibrosis: Risk Factors and Incidence Estimation
Sadowski, E. A., Bennett, L. K., Chan, M. R., Wentland, A. L., Garrett, A. L., Garrett, R. W., & Djamali, A. (2007) · Radiology · doi:10.1148/radiol.2431062144 · Cited by 1,018 · cited 14×
“NCE-MRA has been available since the beginning of MR imaging and is routinely used for intracranial imaging.”
BackgroundInfluentialCoronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903 · cited 1×
“5T [33-37], but its clinical use has been limited by limitations in visualizing distal segment and small branch disease [38].”
BackgroundMR Procedures: Biologic Effects, Safety, and Patient Care
Shellock, F. G., & Crues, J. V. (2004) · Radiology · doi:10.1148/radiol.2323030830 · Cited by 563
Stalder, A. F., Russe, M. F., Frydrychowicz, A., Bock, J., Hennig, J., & Markl, M. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21778 · Cited by 474
Miyazaki, M., & Lee, V. S. (2008) · Radiology · doi:10.1148/radiol.2481071497 · Cited by 407
MR angiography by multiple thin slab 3D acquisition
Parker, D. L., Yuan, C., & Blatter, D. D. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170215 · Cited by 282 · cited 1×
“While the saturation of protons within the in-plane vessels is the greatest limitation of TOF, it can be overcome by the use of progressively increasing flip angles through the slab to compensate for the saturation of blood flowing into the slab [48], multiple overlapping thin slab acquisition (MOTSA), which acquires…”
BackgroundCentral brightening due to constructive interference with, without, and despite dielectric resonance
Collins, C. M., Liu, W., Schreiber, W., Yang, Q. X., & Smith, M. B. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20245 · Cited by 245 · cited 1×
“This shortened wavelength can span the dimensions of the field of view for abdominal and pelvic imaging, occurring more frequently in persons with a large body habitus [22].”
BackgroundProvenzale, J. M., & Sarikaya, B. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1688 · Cited by 242 · cited 1×
“[31] found similar diagnostic quality in MRI combined with MRA compared to CTA for carotid and vertebral dissection without clear superiority of either method.”
ResultFast‐kzthree‐dimensional tailored radiofrequency pulse for reducedB1inhomogeneity
Saekho, S., Yip, C., Noll, D. C., Boada, F. E., & Stenger, V. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20840 · Cited by 206 · cited 1×
“In addition to improved coil design, new pulse sequences such as three-dimensional tailored RF pulses have been shown to improve homogeneity of the radiofrequency excitation[25].”
BackgroundContrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3.0-T
Yang, Q., Li, K., Liu, X., Bi, X., Liu, Z., An, J., Zhang, A., Jerec̆ić, R., & Li, D. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.03.016 · Cited by 201
Efficient high‐frequency body coil for high‐field MRI
Vaughan, J. T., Adriany, G., Snyder, C., Tian, J., Thiel, T., Bolinger, L., Liu, H., DelaBarre, L. J., & Uǧurbil, K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20177 · Cited by 193 · cited 1×
“Advances in coil design, such as multicoil transmit body coils, can suppress eddy currents and improve RF field homogeniety at higher field strengths [24].”
BackgroundAgarwal, R., Brunelli, S. M., Williams, K., Mitchell, M. D., Feldman, H. I., & Umscheid, C. A. (2008) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfn593 · Cited by 174 · cited 1×
“[28] identified the odds of developing NSF were 27 times greater in patients with chronic kidney disease (N = 79/1393, 5.”
BackgroundMR angiography by selective inversion recovery
Nishimura, D. G., Macovski, A., Pauly, J. M., & Conolly, S. M. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910040214 · Cited by 171 · cited 1×
“Background tissue can be suppressed by subtracting the untagged image from the tagged blood image in two acquisitions [58] or by applying a spatially nonselective tag pulse of the entire imaging field in addition to the tag pulse applied to the arteries of interest in a single acquisition [30].”
BackgroundBody MR Imaging at 3.0 T: Understanding the Opportunities and Challenges
Barth, M. M., Smith, M. P., Pedrosa, I., Lenkinski, R. E., & Rofsky, N. M. (2007) · Radiographics · doi:10.1148/rg.275065204 · Cited by 142 · cited 2×
“Increased spatial resolution allows for improved visibility of lesions, and faster acquisition times helps reduce motion artifact and decrease breathholding requirements [ 2 ].”
BackgroundKrishnam, M. S., Tomasian, A., Malik, S. B., Desphande, V., Laub, G. A., & Ruehm, S. G. (2009) · European Radiology · doi:10.1007/s00330-009-1672-3 · Cited by 131 · cited 1×
“A study by Krishnam et al. [ 54 ] demonstrated that free-breathing ECG-gated SSFP MRA of the thoracic aorta had equal diagnostic sensitivity and specificity compared to CE-MRA in 50 patients with suspected thoracic aorta disease.”
MethodDielectric Resonance Phenomena in Ultra High Field MRI
Kangarlu, A., Baertlein, B. A., Lee, R., Ibrahim, T. S., Yang, L., Abduljalil, A., & Robitaille, P.-M. L. (1999) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199911000-00003 · Cited by 122 · cited 1×
“Electrical current circulates within the fluid under the strong magnetic field and interferes with the RF field pulses resulting in interference [23].”
BackgroundBi, X., Carr, J., & Li, D. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21224 · Cited by 113 · cited 1×
“0T, contrast-enhanced coronary MRA methods have been revisited with promising initial results [41-45].”
BackgroundBorisch, I., Horn, M., Butz, B., Zorger, N., Draganski, B., Hoelscher, T., Bogdahn, U., & Link, J. (2003) · PubMed Central · Cited by 106
Krautmacher, C., Willinek, W. A., Tschampa, H. J., Born, M. L., Träber, F., Gieseke, J., Textor, H. J., Schild, H. H., & Kuhl, C. K. (2005) · Radiology · doi:10.1148/radiol.2373041672 · Cited by 100 · cited 1×
“The increase in CNR at 3.0T can be used to improve the image quality using the same amount of contrast or to decrease the amount of IV contrast injected compared to a similar scan at 1.5T (Figure 2) [5, 9 ].”
MethodLiu, X., Zhao, X., Huang, J., François, C. J., Tuite, D. J., Bi, X., Li, D., & Carr, J. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2805 · Cited by 97 · cited 1×
“In addition, coronary MRA may have a role in evaluating patients with significant stenosis in coronary artery segments with moderate to severe calcification, due to increased artifact and difficulty visualizing stenosis with CTA in patients with high calcium scores [ 39 ].”
BackgroundSelf-citationLotz, J., Döker, R., Noeske, R., Schüttert, M., Felix, R., Galanski, M., Gutberlet, M., & Meyer, G. P. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20275 · Cited by 88 · cited 1×
“This allows VENC to be increased, reducing aliasing artifacts in regions of higher flow without increasing overall image noise to unacceptable levels [ 64 ].”
BackgroundLiu, X., Bi, X., Huang, J., Jerec̆ić, R., Carr, J., & Li, D. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e31817ed1ff · Cited by 83
Lum, D. P., Johnson, K. M., Paul, R. K., Turk, A. S., Consigny, D. W., Grinde, J. R., Mistretta, C. A., & Grist, T. M. (2007) · Radiology · doi:10.1148/radiol.2453061946 · Cited by 75 · cited 1×
“In addition, the 4D PC MRA techniques can be used to qualitatively evaluate the complex flow patterns within the cardiovascular system (Figure 14) [65,67-69] and calculate various hemodynamic parameters non-invasively, including pressure gradients [ 70 ,71,61], wall shear stress, and oscillatory stress index [68,72].”
MethodSelf-citationRandoux, B., Marro, B., Koskas, F., Jacques Chiras, C., Dormont, D., & Marsault, C. (2003) · Radiology · doi:10.1148/radiol.2292011648 · Cited by 72 · cited 1×
“CE-MRA has been established as a non-invasive alternative to conventional angiography in evaluating peripheral vascular disease [10-12] and can be an alternative to CTA for the diagnosis of acute pulmonary embolism [13].”
BackgroundParallel Imaging in MR Angiography
Wilson, G. J., Hoogeveen, R. M., Willinek, W. A., Muthupillai, R., & Maki, J. H. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/01.rmr.0000134199.94874.70 · Cited by 62 · cited 1×
“Parallel imaging has been applied to CE-MRA to reduce scan time and improve spatial resolution by improving anatomic coverage and removing aliasing artifact with the use of multiple channel coils (Figure 4) [19].”
MethodAdvanced kidney disease, gadolinium and nephrogenic systemic fibrosis: the perfect storm
Perazella, M. A. (2009) · Current Opinion in Nephrology & Hypertension · doi:10.1097/mnh.0b013e3283309660 · Cited by 48 · cited 14×
“NCE-MRA has been available since the beginning of MR imaging and is routinely used for intracranial imaging.”
BackgroundInfluentialHabibi, R., Krishnam, M. S., Lohan, D. G., Barkhordarian, F., Jalili, M., Saleh, R. S., Ruehm, S. G., & Finn, J. P. (2008) · Radiology · doi:10.1148/radiol.2482071505 · Cited by 43 · cited 1×
“It has been shown that the amount of Gd-contrast needed at 3.0T for lower extremity MRA can be reduced up to one-third of that used at 1.5T (i.e. from 0.3 mmol/kg to 0.1 mmol/kg) [ 15 ].”
BackgroundInfluentialTomasian, A., Salamon, N., Lohan, D. G., Jalili, M., Villablanca, J. P., & Finn, J. P. (2008) · Radiology · doi:10.1148/radiol.2493080209 · Cited by 41 · cited 3×
“The increase in CNR at 3.0T can be used to improve the image quality using the same amount of contrast or to decrease the amount of IV contrast injected compared to a similar scan at 1.5T (Figure 2) [ 5 ,9].”
BackgroundMethodInfluentialLum, D. P., Busse, R. F., François, C. J., Brau, A. C. S., Beatty, P. J., Huff, J., Brittain, J. H., & Reeder, S. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21964 · Cited by 30 · cited 1×
“[21] recently demonstrated the use of a two-dimensional autocalibrating parallel imaging tech-”
MethodSelf-citationContrast‐enhanced 4D radial coronary artery imaging at 3.0 T within a single breath‐hold
Bi, X., Park, J., Larson, A. C., Zhang, Q., Simonetti, O. P., & Li, D. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20575 · Cited by 29 · cited 1×
“0T, contrast-enhanced coronary MRA methods have been revisited with promising initial results [41-45].”
BackgroundErsoy, H., Zhang, H., & Prince, M. R. (2006) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640600604963 · Cited by 28
3.0 T versus 1.5 T MR Angiography of the Head and Neck
DeLano, M. C., & DeMarco, J. K. (2006) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2006.03.002 · Cited by 26
Turk, A. S., Johnson, K. M., Lum, D. P., Niemann, D., Aagaard‐Kienitz, B., Consigny, D. W., Grinde, J. R., Turski, P. A., Haughton, V. M., & Mistretta, C. A. (2007) · PubMed Central · Cited by 25
Wyttenbach, R., Corti, R., Alerci, M., Cozzi, L., Valentino, M. D., Segatto, J.-M., Badimón, J. J., Fuster, V., & Gallino, A. (2007) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2007.05.017 · Cited by 15 · cited 1×
“[56] evaluated 53 patients suspected of renal artery stenosis with 3D SSFP and CE-MRA at 1.”
Background
Cited by
Chaer, R. A., Abularrage, C. J., Coleman, D. M., Eslami, M. H., Kashyap, V. S., Rockman, C., & Murad, M. H. (2020) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2020.01.039 · Cited by 645
25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420
Self-citationRadiotherapy planning using MRI
Schmidt, M. A., & Payne, G. S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/22/r323 · Cited by 357
Cardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“Non-contrast-enhanced MRA (NCE-MRA) techniques rely on changes in the MR signal that are caused by the motion of blood through or within the image plane.”
Influential
Metadata
- Authors
- Hartung, M. P., Grist, T. M., & François, C. J.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 13
- Issue
- 1
- Pages
- 19
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2103958626
- Cited by
- 213
- References
- 37
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.