Myocardial T1 and extracellular volume fraction mapping at 3 tesla
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To compare 11 heartbeat (HB) and 17 HB modified lock locker inversion recovery (MOLLI) pulse sequence at 3T and to establish preliminary reference values for myocardial T1 and the extracellular volume fraction (ECV). METHODS: Both phantoms and normal volunteers were scanned at 3T using 11 HB and 17 HB MOLLI sequence with the following parameters: spatial resolution = 1.75 × 1.75 × 10 mm on a 256 × 180 matrix, TI initial = 110 ms, TI increment = 80 ms, flip angle = 35°, TR/TE = 1.9/1.0 ms. All volunteers were administered Gadolinium-DTPA (Magnevist, 0.15 mmol/kg), and multiple post-contrast MOLLI scans were performed at the same pre-contrast position from 3.5-23.5 minutes after a bolus contrast injection. Late gadolinium enhancement (LGE) images were also acquired 12-30 minutes after the gadolinium bolus. RESULTS: T1 values of 11 HB and 17 HB MOLLI displayed good agreement in both phantom and volunteers. The average pre-contrast myocardial and blood T1 was 1315 ± 39 ms and 2020 ± 129 ms, respectively. ECV was stable between 8.5 to 23.5 minutes post contrast with an average of 26.7 ± 1.0%. CONCLUSION: The 11 HB MOLLI is a faster method for high-resolution myocardial T1 mapping at 3T. ECV fractions are stable over a wide time range after contrast administration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266 · cited 2×
“For pre-contrast myocardial T1 times, our results (1315 ms) are shorter than those obtained by Stanisz et al [19] (1471 ms), but longer than the results acquired by Piechnik et al [6] (1169 ms), Sharma et al [20] (1200 ms) and Noeske et al [16] (1115 ms).”
Result
Cited by
T1-mapping in the heart: accuracy and precision
Kellman, P., & Hansen, M. S. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-2 · Cited by 764
Self-citationNormal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Self-citationKawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Self-citationWong, T. C., Piehler, K., Meier, C. G., Testa, S. M., Klock, A. M., Aneizi, A. A., Shakesprere, J., Kellman, P., Shroff, S. G., Schwartzman, D. S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.089409 · Cited by 493
Self-citationExtracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated method
Kellman, P., Wilson, J. R., Xue, H., Ugander, M., & Arai, A. E. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-63 · Cited by 427
Self-citationMiller, C. A., Naish, J. H., Bishop, P., Coutts, G., Clark, D., Zhao, S., Ray, S. G., Yonan, N., Williams, S. G., Flett, A. S., et al. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.000192 · Cited by 384
Wong, T. C., Piehler, K. M., Kang, I. A., Kadakkal, A., Kellman, P., Schwartzman, D. S., Mulukutla, S. R., Simon, M. A., Shroff, S. G., Kuller, L. H., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht193 · Cited by 379
Self-citationLiu, C.-Y., Liu, Y.-C., Wu, C., Armstrong, A., Volpe, G. J., van der Geest, R. J., Liu, Y., Hundley, W. G., Gomes, A. S., Liu, S., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.078 · Cited by 349
Self-citationDabir, D., Child, N., Kalra, A., Rogers, T., Gebker, R., Jabbour, A., Plein, S., Yu, C.-Y., Otton, J., Kidambi, A., et al. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0069-x · Cited by 347
T1 Mapping in Characterizing Myocardial Disease: A Comprehensive Review
Puntmann, V. O., Peker, E., Chandrashekhar, Y., & Nagel, E. (2016) · Circulation Research · doi:10.1161/circresaha.116.307974 · Cited by 337
T1 Mapping in Cardiomyopathy at Cardiac MR: Comparison with Endomyocardial Biopsy
Sibley, C. T., Noureldin, R. A., Gai, N., Nacif, M. S., Liu, S., Turkbey, E. B., Mudd, J. O., van der Geest, R. J., Lima, J. A. C., Halushka, M. K., et al. (2012) · Radiology · doi:10.1148/radiol.12112721 · Cited by 303
Self-citationPiechnik, S. K., Ferreira, V. M., Lewandowski, A. J., Ntusi, N. A., Banerjee, R., Holloway, C., Hofman, M. B., Sado, D. M., Maestrini, V., White, S. K., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-13 · Cited by 273
Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications
von Knobelsdorff-Brenkenhoff, F., Prothmann, M., Dieringer, M. A., Wassmuth, R., Greiser, A., Schwenke, C., Niendorf, T., & Schulz-Menger, J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-53 · Cited by 265
Nakamori, S., Dohi, K., Ishida, M., Goto, Y., Imanaka-Yoshida, K., Omori, T., Goto, I., Kumagai, N., Fujimoto, N., Ichikawa, Y., et al. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.04.006 · Cited by 260
Extracellular volume fraction mapping in the myocardium, part 2: initial clinical experience
Kellman, P., Wilson, J. R., Xue, H., Bandettini, W. P., Shanbhag, S. M., Druey, K. M., Ugander, M., & Arai, A. E. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-64 · Cited by 259
Self-citationEverett, R. J., Tastet, L., Clavel, M.-A., Chin, C. W. L., Capoulade, R., Vassiliou, V. S., Kwiecinski, J., Gomez, M., van Beek, E. J. R., White, A. C., et al. (2018) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.007451 · Cited by 202
Diao, K.-Y., Yang, Z.-G., Xu, H.-Y., Liu, X., Zhang, Q., Shi, K., Jiang, L., Xie, L.-J., Wen, L.-Y., & Guo, Y.-K. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0313-7 · Cited by 167
Metadata
- Authors
- Lee, J. J., Liu, S., Nacif, M. S., Ugander, M., Han, J., Kawel, N., Sibley, C. T., Kellman, P., Arai, A. E., & Bluemke, D. A.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 13
- Issue
- 1
- Pages
- 75
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2152160146
- Cited by
- 172
- References
- 1
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.