Myocardial T1 and extracellular volume fraction mapping at 3 tesla
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To compare 11 heartbeat (HB) and 17 HB modified lock locker inversion recovery (MOLLI) pulse sequence at 3T and to establish preliminary reference values for myocardial T1 and the extracellular volume fraction (ECV). METHODS: Both phantoms and normal volunteers were scanned at 3T using 11 HB and 17 HB MOLLI sequence with the following parameters: spatial resolution = 1.75 × 1.75 × 10 mm on a 256 × 180 matrix, TI initial = 110 ms, TI increment = 80 ms, flip angle = 35°, TR/TE = 1.9/1.0 ms. All volunteers were administered Gadolinium-DTPA (Magnevist, 0.15 mmol/kg), and multiple post-contrast MOLLI scans were performed at the same pre-contrast position from 3.5-23.5 minutes after a bolus contrast injection. Late gadolinium enhancement (LGE) images were also acquired 12-30 minutes after the gadolinium bolus. RESULTS: T1 values of 11 HB and 17 HB MOLLI displayed good agreement in both phantom and volunteers. The average pre-contrast myocardial and blood T1 was 1315 ± 39 ms and 2020 ± 129 ms, respectively. ECV was stable between 8.5 to 23.5 minutes post contrast with an average of 26.7 ± 1.0%. CONCLUSION: The 11 HB MOLLI is a faster method for high-resolution myocardial T1 mapping at 3T. ECV fractions are stable over a wide time range after contrast administration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266 · cited 2×
“For pre-contrast myocardial T1 times, our results (1315 ms) are shorter than those obtained by Stanisz et al [19] (1471 ms), but longer than the results acquired by Piechnik et al [6] (1169 ms), Sharma et al [20] (1200 ms) and Noeske et al [16] (1115 ms).”
ResultBottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192 · cited 1×
“T1 values are field strength dependent and increase with field strength [15].”
BackgroundFlett, A. S., Hayward, M. P., Ashworth, M. T., Hansen, M. S., Taylor, A. M., Elliott, P. M., McGregor, C., & Moon, J. C. (2010) · Circulation · doi:10.1161/circulationaha.109.930636 · Cited by 915
WRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Self-citationPiechnik, S. K., Ferreira, V. M., Dall'Armellina, E., Cochlin, L. E., Greiser, A., Neubauer, S., & Robson, M. D. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-69 · Cited by 670 · cited 3×
“Several new protocols have been proposed to reduce the MOLLI acquisition time [6,7].”
BackgroundResultACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
Self-citationArheden, H., Saeed, M., Higgins, C. B., Gao, D.-W., Bremerich, J., Wyttenbach, R., Dae, M. W., & Wendland, M. F. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn41698 · Cited by 358 · cited 2×
“Extracellular volume fraction (ECV), fibrosis index [9], or volume of distribution [10,11] are similar methods that measure the myocardial extracellular volume fraction by normalizing myocardial R1 change with blood R1 change and by correction for hematocrit.”
BackgroundMethodMessroghli, D. R., Greiser, A., Fröhlich, M., Dietz, R., & Schulz‐Menger, J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21119 · Cited by 353 · cited 2×
“A high-resolution T1 map of the myocardium can be acquired in one breath hold [4,5].”
BackgroundMethodBroberg, C. S., Chugh, S. S., Conklin, C., Sahn, D. J., & Jerosch-Herold, M. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.842096 · Cited by 262 · cited 3×
“%) slightly higher than the “fibrosis index” of normal volunteers reported by Broberg et al [9] (24.8”
BackgroundMethodInfluentialSchelbert, E. B., Testa, S. M., Meier, C. G., Ceyrolles, W. J., Levenson, J. E., Blair, A. J., Kellman, P., Jones, B. L., Ludwig, D. R., Schwartzman, D., et al. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-16 · Cited by 242 · cited 6×
“A study conducted by Schelbert et al [7] introduced a hybrid MOLLI protocol adapted to the expected pre-contrast or post-contrast T1 values.”
BackgroundMethodResultSelf-citationMessroghli, D. R., Plein, S., Higgins, D. M., Walters, K., Jones, T. R., Ridgway, J. P., & Sivananthan, M. U. (2006) · Radiology · doi:10.1148/radiol.2382041903 · Cited by 239 · cited 3×
“A high-resolution T1 map of the myocardium can be acquired in one breath hold [4,5].”
BackgroundMethodMarijianowski, M. M. H., Teeling, P., Mann, J., & Becker, A. E. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00557-7 · Cited by 210 · cited 1×
“Myocardial fibrosis is one of the most common histological features of the failing heart [2].”
BackgroundDelayed Enhancement MR Imaging: Utility in Myocardial Assessment
Vogel-Claussen, J., Rochitte, C. E., Wu, K. C., Kamel, I. R., Foo, T. K., Lima, J. A. C., & Bluemke, D. A. (2006) · RadioGraphics · doi:10.1148/rg.263055047 · Cited by 178 · cited 1×
“Late gadolinium enhancement (LGE) has been the standard of reference for detecting focal myocardial fibrosis in clinical practice [3].”
BackgroundSelf-citationHuman cardiac imaging at 3 T using phased array coils
Noeske, R., Seifert, F. C., Rhein, K. H., & Rinneberg, H. H. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200012)44:6<978::aid-mrm22>3.0.co;2-9 · Cited by 167 · cited 3×
“Cardiac imaging has been slow to adopt 3T imaging because of the inhomogeneities of both static magnetic field (B0) and the transmit radiofrequency field (B1) [16].”
MethodResultGai, N., Turkbey, E. B., Nazarian, S., van der Geest, R. J., Liu, C., Lima, J. A. C., & Bluemke, D. A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22716 · Cited by 128
Self-citationMessroghli, D., Nordmeyer, S., Dietrich, T., Dirsch, O., Kaschina, E., Savvatis, K., h-Icí, D. O., Klein, C., Berger, F. F., & Kühne, T. (2011) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.111.966796 · Cited by 116
Effect of Gd‐DTPA‐BMA on blood and myocardial T1 at 1.5T and 3T in humans
Sharma, P., Socolow, J., Patel, S. J., Pettigrew, R. I., & Oshinski, J. N. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20504 · Cited by 98 · cited 2×
“For pre-contrast myocardial T1 times, our results (1315 ms) are shorter than those obtained by Stanisz et al [19] (1471 ms), but longer than the results acquired by Piechnik et al [6] (1169 ms), Sharma et al [20] (1200 ms) and Noeske et al [16] (1115 ms).”
ResultMessroghli, D., Rudolph, A., Abdel‐Aty, H., Waßmuth, R., Kühne, T., Dietz, R., & Schulz‐Menger, J. (2010) · BMC Medical Imaging · doi:10.1186/1471-2342-10-16 · Cited by 94 · cited 2×
“For both phantom and human studies, T1 maps were calculated using MRmap [14] and stored in Digital Imaging and Communications in Medicine (DICOM) Format.”
MethodInulin as an Indicator for the Extracellular Space
Kruhøffer, P. (1946) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1946.tb00325.x · Cited by 67 · cited 1×
“Extracellular volume fraction (ECV) [22,23], volume of distribution (Vd)[10], fibrosis index [24], and volume fraction of extravascular extracellular matrix (Ve) [7] all share the same parameters for measuring the myocardial extracellular matrix by adjusting the gadolinium contrast partition coefficient with the patie…”
Background
Cited by
T1-mapping in the heart: accuracy and precision
Kellman, P., & Hansen, M. S. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-2 · Cited by 764
Self-citationNormal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Self-citationKawel-Boehm, N., Hetzel, S. J., Ambale-Venkatesh, B., Captur, G., Francois, C. J., Jerosch-Herold, M., Salerno, M., Teague, S. D., Valsangiacomo-Buechel, E., van der Geest, R. J., et al. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00683-3 · Cited by 610
Self-citationWong, T. C., Piehler, K., Meier, C. G., Testa, S. M., Klock, A. M., Aneizi, A. A., Shakesprere, J., Kellman, P., Shroff, S. G., Schwartzman, D. S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.089409 · Cited by 493
Self-citationExtracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated method
Kellman, P., Wilson, J. R., Xue, H., Ugander, M., & Arai, A. E. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-63 · Cited by 427
Self-citation
Metadata
- Authors
- Lee, J. J., Liu, S., Nacif, M. S., Ugander, M., Han, J., Kawel, N., Sibley, C. T., Kellman, P., Arai, A. E., & Bluemke, D. A.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 13
- Issue
- 1
- Pages
- 75
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2152160146
- Cited by
- 172
- References
- 19
- FWCI
- 11.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.