The influence of colloidal parameters on the specific power absorption of PAA-coated magnetite nanoparticles
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The suitability of magnetic nanoparticles (MNPs) to act as heat nano-sources by application of an alternating magnetic field has recently been studied due to their promising applications in biomedicine. The understanding of the magnetic relaxation mechanism in biocompatible nanoparticle systems is crucial in order to optimize the magnetic properties and maximize the specific absorption rate (SAR). With this aim, the SAR of magnetic dispersions containing superparamagnetic magnetite nanoparticles bio-coated with polyacrylic acid of an average particle size of ≈10 nm has been evaluated separately by changing colloidal parameters such as the MNP concentration and the viscosity of the solvent. A remarkable decrease of the SAR values with increasing particle concentration and solvent viscosity was found. These behaviours have been discussed on the basis of the magnetic relaxation mechanisms involved. PACS: 80; 87; 87.85jf
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852 · cited 2×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodApplications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Deacon, G. (1980) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(00)80455-5 · Cited by 5,123 · cited 3×
“Deacon GB, Phillips RJ: Relationships between the carbon-oxygen stretching frequencies of carboxylato complexes and the type of carboxylate coordination.”
BackgroundInfluentialApplications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565 · cited 3×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodHeating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,551
Size-Sorted Anionic Iron Oxide Nanomagnets as Colloidal Mediators for Magnetic Hyperthermia
Fortin, J.-P., Wilhelm, C., Servais, J., Ménager, C., Bacri, J.-C., & Gazeau, F. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067457e · Cited by 1,038 · cited 3×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodGupta, A. K., Naregalkar, R. R., Vaidya, V. D., & Gupta, M. (2007) · Nanomedicine · doi:10.2217/17435889.2.1.23 · Cited by 708 · cited 1×
“Adequately coated iron oxide-based nanoparticles have been the most extensively studied material in hyperthermia experiments because they have very low toxicity, making them suitable for in vivo applications [11,12].”
BackgroundPhysical limits of hyperthermia using magnetite fine particles
Hergt, R., Andra, W., d'Ambly, C. G., Hilger, I., Kaiser, W. A., Richter, U., & Schmidt, H.-G. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.718537 · Cited by 658 · cited 2×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodInductively Heated Shape Memory Polymer for the Magnetic Actuation of Medical Devices
Buckley, P. R., McKinley, G. H., Wilson, T. S., Small, W., Benett, W. J., Bearinger, J. P., McElfresh, M. W., & Maitland, D. J. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.877113 · Cited by 361 · cited 1×
“It is important to mention that such a similar concentration heating efficiency was also observed in a different than magnetite system based on Ni-Zn ferrite nanoparticles dispersed in a shape memory polymer [22].”
BackgroundSize-dependant heating rates of iron oxide nanoparticles for magnetic fluid hyperthermia
Gonzales-Weimuller, M., Zeisberger, M., & Krishnan, K. M. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2008.12.017 · Cited by 330 · cited 2×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethod
Cited by
Fundamentals and advances in magnetic hyperthermia
Périgo, E. A., Hemery, G., Sandre, O., Ortega, D., Garaio, E., Plazaola, F., & Teran, F. J. (2015) · Applied Physics Reviews · doi:10.1063/1.4935688 · Cited by 836
Heating efficiency in magnetic nanoparticle hyperthermia
Deatsch, A. E., & Evans, E. E. (2014) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2013.11.006 · Cited by 811
Advances in Magnetic Nanoparticles for Biomedical Applications
Cardoso, V. F., Francesko, A., Ribeiro, C., Bañobre‐López, M., Martins, P., & Lanceros‐Mendez, S. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700845 · Cited by 723
Self-citationMagnetic nanoparticle-based hyperthermia for cancer treatment
Bañobre-López, M., Teijeiro, A., & Rivas, J. (2013) · Reports of Practical Oncology & Radiotherapy · doi:10.1016/j.rpor.2013.09.011 · Cited by 545
Self-citationMartinez-Boubeta, C., Simeonidis, K., Makridis, A., Angelakeris, M., Iglesias, O., Guardia, P., Cabot, A., Yedra, L., Estradé, S., Peiró, F., et al. (2013) · Scientific Reports · doi:10.1038/srep01652 · Cited by 539
Gavilán, H., Avugadda, S. K., Fernández-Cabada, T., Soni, N., Cassani, M., Mai, B. T., Chantrell, R., & Pellegrino, T. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00427a · Cited by 525
Magnetic Properties of Magnetic Nanoparticles for Efficient Hyperthermia
Obaidat, I., Issa, B., & Haik, Y. (2015) · Nanomaterials · doi:10.3390/nano5010063 · Cited by 495
Magnetic Hyperthermia with Magnetic Nanoparticles: A Status Review
Salunkhe, A. B., Khot, V. M., & Pawar, S. H. (2014) · Current Topics in Medicinal Chemistry · doi:10.2174/1568026614666140118203550 · Cited by 263
Photo-fluorescent and magnetic properties of iron oxide nanoparticles for biomedical applications
Shi, D., Sadat, M. E., Dunn, A. W., & Mast, D. B. (2015) · Nanoscale · doi:10.1039/c5nr01538c · Cited by 244
Albarqi, H. A., Wong, L. H., Schumann, C., Sabei, F. Y., Korzun, T., Li, X., Hansen, M. N., Dhagat, P., Moses, A. S., Taratula, O., et al. (2019) · ACS Nano · doi:10.1021/acsnano.8b06542 · Cited by 215
Evaluation of magnetic nanoparticles for magnetic fluid hyperthermia
Lanier, O. L., Korotych, O. I., Monsalve, A. G., Wable, D., Savliwala, S., Grooms, N. W. F., Nacea, C., Tuitt, O. R., & Dobson, J. (2019) · International Journal of Hyperthermia · doi:10.1080/02656736.2019.1628313 · Cited by 167
Ovejero, J. G., Cabrera, D., Carrey, J., Valdivielso, T., Salas, G., & Teran, F. J. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c6cp00468g · Cited by 160
Metadata
- Authors
- Piñeiro-Redondo, Y., Bañobre-López, M., Pardiñas-Blanco, I., Goya, G., López-Quintela, M. A., & Rivas, J.
- Venue
- Nanoscale Research Letters
- Published
- 2011-05-16
- Volume
- 6
- Issue
- 1
- Pages
- 383-383
- ISSN
- 1556-276X (ISSN-L)
- OpenAlex
- W2127253433
- Cited by
- 165
- References
- 27
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.