The influence of colloidal parameters on the specific power absorption of PAA-coated magnetite nanoparticles
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The suitability of magnetic nanoparticles (MNPs) to act as heat nano-sources by application of an alternating magnetic field has recently been studied due to their promising applications in biomedicine. The understanding of the magnetic relaxation mechanism in biocompatible nanoparticle systems is crucial in order to optimize the magnetic properties and maximize the specific absorption rate (SAR). With this aim, the SAR of magnetic dispersions containing superparamagnetic magnetite nanoparticles bio-coated with polyacrylic acid of an average particle size of ≈10 nm has been evaluated separately by changing colloidal parameters such as the MNP concentration and the viscosity of the solvent. A remarkable decrease of the SAR values with increasing particle concentration and solvent viscosity was found. These behaviours have been discussed on the basis of the magnetic relaxation mechanisms involved. PACS: 80; 87; 87.85jf
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852 · cited 2×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodApplications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Deacon, G. (1980) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(00)80455-5 · Cited by 5,123 · cited 3×
“Deacon GB, Phillips RJ: Relationships between the carbon-oxygen stretching frequencies of carboxylato complexes and the type of carboxylate coordination.”
BackgroundInfluentialApplications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565 · cited 3×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodHeating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,551
Size-Sorted Anionic Iron Oxide Nanomagnets as Colloidal Mediators for Magnetic Hyperthermia
Fortin, J.-P., Wilhelm, C., Servais, J., Ménager, C., Bacri, J.-C., & Gazeau, F. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067457e · Cited by 1,038 · cited 3×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodGupta, A. K., Naregalkar, R. R., Vaidya, V. D., & Gupta, M. (2007) · Nanomedicine · doi:10.2217/17435889.2.1.23 · Cited by 708 · cited 1×
“Adequately coated iron oxide-based nanoparticles have been the most extensively studied material in hyperthermia experiments because they have very low toxicity, making them suitable for in vivo applications [11,12].”
BackgroundPhysical limits of hyperthermia using magnetite fine particles
Hergt, R., Andra, W., d'Ambly, C. G., Hilger, I., Kaiser, W. A., Richter, U., & Schmidt, H.-G. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.718537 · Cited by 658 · cited 2×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodInductively Heated Shape Memory Polymer for the Magnetic Actuation of Medical Devices
Buckley, P. R., McKinley, G. H., Wilson, T. S., Small, W., Benett, W. J., Bearinger, J. P., McElfresh, M. W., & Maitland, D. J. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.877113 · Cited by 361 · cited 1×
“It is important to mention that such a similar concentration heating efficiency was also observed in a different than magnetite system based on Ni-Zn ferrite nanoparticles dispersed in a shape memory polymer [22].”
BackgroundSize-dependant heating rates of iron oxide nanoparticles for magnetic fluid hyperthermia
Gonzales-Weimuller, M., Zeisberger, M., & Krishnan, K. M. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2008.12.017 · Cited by 330 · cited 2×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodIntracellular heating of living cells through Néel relaxation of magnetic nanoparticles
Fortin, J.-P., Gazeau, F., & Wilhelm, C. (2008) · European Biophysics Journal · doi:10.1007/s00249-007-0197-4 · Cited by 322
Models for the dynamics of interacting magnetic nanoparticles
Hansen, M. F., & Mørup, S. (1998) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(97)01165-7 · Cited by 307 · cited 13×
“Magnetite MNPs of ≈10 nm were synthesized by chemical co-precipitation of an aqueous solution containing Fe2+ (FeSO4·7H2O, 99”
BackgroundInfluentialMetallic Iron Nanoparticles for MRI Contrast Enhancement and Local Hyperthermia
Hadjipanayis, C. G., Bonder, M. J., Balakrishnan, S., Wang, X., Mao, H., & Hadjipanayis, G. C. (2008) · Small · doi:10.1002/smll.200800261 · Cited by 286 · cited 2×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodAndrés Vergés, M., Costo, R., Roca, A. G., Marco, J. F., Goya, G. F., Serna, C. J., & Morales, M. P. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/13/134003 · Cited by 272
Self-citationMagnetism in Medicine: A Handbook
Andrä, W., & (ed), N. N. (1999) · Physiological Measurement · doi:10.1088/0967-3334/20/3/701 · Cited by 234 · cited 2×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodTwo Mechanisms and a Scaling Relation for Dynamics in Ferrofluids
Zhang, J., Boyd, C., & Luo, W. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.390 · Cited by 206 · cited 1×
“particle force is mainly hydrodynamic in nature [18].”
BackgroundMagnetism in Medicine: A Handbook
(2006) · Wiley eBooks · doi:10.1002/9783527610174 · Cited by 200
Thermal degradation of poly(acrylic acid) containing copper nitrate
Dubinsky, S., Grader, G. S., Shter, G. E., & Silverstein, M. S. (2004) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2004.04.009 · Cited by 189
Magnetically induced hyperthermia: size-dependent heating power of γ-Fe2O3 nanoparticles
Lévy, M., Wilhelm, C., Siaugue, J.-M., Horner, O., Bacri, J.-C., & Gazeau, F. (2008) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/20/20/204133 · Cited by 184 · cited 2×
“By performing a linear fit of the hyperthermia data (temperature versus time) in the initial time interval, t = [1-10] s, we obtain”
BackgroundMethodMagnetic nanoparticles for power absorption: Optimizing size, shape and magnetic properties
Gonzalez-Fernandez, M. A., Torres, T. E., Andrés-Vergés, M., Costo, R., de la Presa, P., Serna, C. J., Morales, M. P., Marquina, C., Ibarra, M. R., & Goya, G. F. (2009) · Journal of Solid State Chemistry · doi:10.1016/j.jssc.2009.07.047 · Cited by 167 · cited 2×
“However, although the size dependence of the heating power has been already investigated and indicates the existence of an optimal particle size in which the heating power is maximum [14], there are no systematic data on the influence of particle concentration or solvent properties in the same magnetic system and in a…”
BackgroundMethodSelf-citationMagnetite ferrofluid with high specific absorption rate for application in hyperthermia
Zhang, L.-Y., Gu, H.-C., & Wang, X.-M. (2007) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.11.179 · Cited by 165 · cited 2×
“This tendency agrees with theoretical predictions [10] and experimental results found in dextran-coated magnetite ferrofluids, where a maximum SAR is observed in the interval of 1 < h < 3 mP s [24].”
BackgroundResultUrtizberea, A., Natividad, E., Arizaga, A., Castro, M., & Mediano, A. (2010) · The Journal of Physical Chemistry C · doi:10.1021/jp912076f · Cited by 160 · cited 2×
“In this sense, the maximum of our SAR curve is obtained for a higher viscosity value than [19] because the chemical/physical characteristics of our MNPs (size, morphology, coating, etc.”
BackgroundShao, D., Xu, K., Song, X., Hu, J., Yang, W., & Wang, C. (2009) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2009.02.061 · Cited by 109 · cited 1×
“Furthermore, the biochemical activity of the protein is maintained in the resulting protein-polymer complexes [13].”
BackgroundSize and Concentration Effects on High Frequency Hysteresis of Iron Oxide Nanoparticles
Eggeman, A. S., Majetich, S. A., Farrell, D. F., & Pankhurst, Q. A. (2007) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.894127 · Cited by 106
Dennis, C. L., Jackson, A., Borchers, J. A., Ivkov, R., Foreman, A. R., Lau, J. W., Goernitz, E., & Gruettner, C. (2008) · Journal of Applied Physics · doi:10.1063/1.2837647 · Cited by 105 · cited 1×
“[19] showed a SAR increase with dilution of ≈11 nm maghemita nanoparticles based ferrofluids, although the study was carried out through AC susceptibility measurements performed below ≈100 kHz; and while [20] reported a higher SAR for tightly associated dextran-coated iron oxide nanoparticles (d ≈ 90 nm) than for a mo…”
BackgroundMagnetic fluid based on Fe3O4nanoparticles: Preparation and hyperthermia application
Linh, P. H., Thach, P. V., Tuấn, N. A., Thuan, N. C., Manh, D. H., Phuc, N. X., & Hong, L. V. (2009) · Journal of Physics Conference Series · doi:10.1088/1742-6596/187/1/012069 · Cited by 56 · cited 1×
“[21] for relatively comparable colloidal magnetite based ferrofluid.”
BackgroundBattling Tumors with Magnetic Nanotherapeutics and Hyperthermia: Turning Up The Heat
Campbell, R. B. (2007) · Nanomedicine · doi:10.2217/17435889.2.5.649 · Cited by 48 · cited 1×
“Adequately coated iron oxide-based nanoparticles have been the most extensively studied material in hyperthermia experiments because they have very low toxicity, making them suitable for in vivo applications [11,12].”
Background
Cited by
Fundamentals and advances in magnetic hyperthermia
Périgo, E. A., Hemery, G., Sandre, O., Ortega, D., Garaio, E., Plazaola, F., & Teran, F. J. (2015) · Applied Physics Reviews · doi:10.1063/1.4935688 · Cited by 836
Heating efficiency in magnetic nanoparticle hyperthermia
Deatsch, A. E., & Evans, E. E. (2014) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2013.11.006 · Cited by 811
Advances in Magnetic Nanoparticles for Biomedical Applications
Cardoso, V. F., Francesko, A., Ribeiro, C., Bañobre‐López, M., Martins, P., & Lanceros‐Mendez, S. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700845 · Cited by 723
Self-citationMagnetic nanoparticle-based hyperthermia for cancer treatment
Bañobre-López, M., Teijeiro, A., & Rivas, J. (2013) · Reports of Practical Oncology & Radiotherapy · doi:10.1016/j.rpor.2013.09.011 · Cited by 545
Self-citationMartinez-Boubeta, C., Simeonidis, K., Makridis, A., Angelakeris, M., Iglesias, O., Guardia, P., Cabot, A., Yedra, L., Estradé, S., Peiró, F., et al. (2013) · Scientific Reports · doi:10.1038/srep01652 · Cited by 539
Metadata
- Authors
- Piñeiro-Redondo, Y., Bañobre-López, M., Pardiñas-Blanco, I., Goya, G., López-Quintela, M. A., & Rivas, J.
- Venue
- Nanoscale Research Letters
- Published
- 2011-05-16
- Volume
- 6
- Issue
- 1
- Pages
- 383-383
- ISSN
- 1556-276X (ISSN-L)
- OpenAlex
- W2127253433
- Cited by
- 165
- References
- 27
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.