Removal of muscle artifact from EEG data: comparison between stochastic (ICA and CCA) and deterministic (EMD and wavelet-based) approaches
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
Electroencephalographic (EEG) recordings are often contaminated with muscle artifacts. This disturbing myogenic activity not only strongly affects the visual analysis of EEG, but also most surely impairs the results of EEG signal processing tools such as source localization. This article focuses on the particular context of the contamination epileptic signals (interictal spikes) by muscle artifact, as EEG is a key diagnosis tool for this pathology. In this context, our aim was to compare the ability of two stochastic approaches of blind source separation, namely independent component analysis (ICA) and canonical correlation analysis (CCA), and of two deterministic approaches namely empirical mode decomposition (EMD) and wavelet transform (WT) to remove muscle artifacts from EEG signals. To quantitatively compare the performance of these four algorithms, epileptic spike-like EEG signals were simulated from two different source configurations and artificially contaminated with different levels of real EEG-recorded myogenic activity. The efficiency of CCA, ICA, EMD, and WT to correct the muscular artifact was evaluated both by calculating the normalized mean-squared error between denoised and original signals and by comparing the results of source localization obtained from artifact-free as well as noisy signals, before and after artifact correction. Tests on real data recorded in an epileptic patient are also presented. The results obtained in the context of simulations and real data show that EMD outperformed the three other algorithms for the denoising of data highly contaminated by muscular activity. For less noisy data, and when spikes arose from a single cortical source, the myogenic artifact was best corrected with CCA and ICA. Otherwise when spikes originated from two distinct sources, either EMD or ICA offered the most reliable denoising result for highly noisy data, while WT offered the better denoising result for less noisy data. These results suggest that the performance of muscle artifact correction methods strongly depend on the level of data contamination, and of the source configuration underlying EEG signals. Eventually, some insights into the numerical complexity of these four algorithms are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
De-noising by soft-thresholding
Donoho, D. L. (1995) · IEEE Transactions on Information Theory · doi:10.1109/18.382009 · Cited by 9,619
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
RELATIONS BETWEEN TWO SETS OF VARIATES
HOTELLING, H. (1936) · Biometrika · doi:10.1093/biomet/28.3-4.321 · Cited by 5,263
Adapting to Unknown Smoothness via Wavelet Shrinkage
Donoho, D. L., & Johnstone, I. M. (1995) · Journal of the American Statistical Association · doi:10.1080/01621459.1995.10476626 · Cited by 4,630
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843 · cited 2×
“Under the quasi-static assumption, this potential linearly depends on the current amplitude generated at the level of neuron assemblies or muscles [24].”
BackgroundDelorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 1×
“Independent component analysis (ICA) was successfully applied to EEG denoising for muscular activity [4-13].”
MethodHandbook of Blind Source Separation
Comon, P., & Jutten, C. (2010) · Elsevier eBooks · doi:10.1016/c2009-0-19334-0 · Cited by 1,744
Zero-crossings of a wavelet transform
Mallat, S. (1991) · IEEE Transactions on Information Theory · doi:10.1109/18.86995 · Cited by 704 · cited 1×
“In practice, the DWT can be computed by successively passing the signal xn m 1⁄2 f g through: (i) a high-pass filter producing the detail coefficients, and (ii) a low-pass filter giving the approximation coefficients [43].”
MethodBoudraa, A., & Cexus, J.-C. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.907967 · Cited by 696
Development of EMD-Based Denoising Methods Inspired by Wavelet Thresholding
Kopsinis, Y., & McLaughlin, S. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2009.2013885 · Cited by 676
Image compression via joint statistical characterization in the wavelet domain
Buccigrossi, R. W., & Simoncelli, E. P. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.806616 · Cited by 523 · cited 1×
“, [36-42]).”
Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
An improved Hilbert–Huang transform and its application in vibration signal analysis
Peng, Z. K., Tse, P. W., & Chu, F. L. (2005) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2004.10.005 · Cited by 463
Ovbiagele, B. I., Kidwell, C. S., & Saver, J. L. (2005) · Cited by 454
Relevance of nonlinear lumped-parameter models in the analysis of depth-EEG epileptic signals
Wendling, F., Bellanger, J. J., Bartolomei, F., & Chauvel, P. (2000) · Biological Cybernetics · doi:10.1007/s004220000160 · Cited by 409
Self-citationSpace or time adaptive signal processing by neural network models
Herault, J., & Jutten, C. (1986) · AIP Conference Proceedings · doi:10.1063/1.36258 · Cited by 403
Mijović, B., De Vos, M., Gligorijević, I., Taelman, J., & Van Huffel, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2051440 · Cited by 382
Semi-automatic identification of independent components representing EEG artifact
Campos Viola, F., Thorne, J., Edmonds, B., Schneider, T., Eichele, T., & Debener, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.015 · Cited by 364
Texture analysis based on local analysis of the Bidimensional Empirical Mode Decomposition
Nunes, J., Guyot, S., & Delchelle, E. (2005) · Machine Vision and Applications · doi:10.1007/s00138-004-0170-5 · Cited by 323
Independent Component Analysis as a Tool to Eliminate Artifacts in EEG: A Quantitative Study
Iriarte, J., Urrestarazu, E., Valencia, M., Alegre, M., Malanda, A., Viteri, C., & Artieda, J. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200307000-00004 · Cited by 289
Denoising Nonlinear Time Series by Adaptive Filtering and Wavelet Shrinkage: A Comparison
Gao, J., Sultan, H., Hu, J., & Tung, W. (2009) · IEEE Signal Processing Letters · doi:10.1109/lsp.2009.2037773 · Cited by 256
Ica: a potential tool for bci systems
Kachenoura, A., Albera, L., Senhadji, L., & Comon, P. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408442 · Cited by 225
Self-citationGoncalves, S. I., de Munck, J. C., Verbunt, J. P. A., Bijma, F., Heethaar, R. M., & Lopes da Silva, F. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812164 · Cited by 219
Comparing wavelet transforms for recognizing cardiac patterns
Senhadji, L., Carrault, G., Bellanger, J. J., & Passariello, G. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.376755 · Cited by 211
Self-citationValidation of ICA-based myogenic artifact correction for scalp and source-localized EEG
McMenamin, B. W., Shackman, A. J., Maxwell, J. S., Bachhuber, D. R. W., Koppenhaver, A. M., Greischar, L. L., & Davidson, R. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.010 · Cited by 211
Multivariate denoising using wavelets and principal component analysis
Aminghafari, M., Cheze, N., & Poggi, J.-M. (2006) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2004.12.010 · Cited by 193 · cited 1×
“Regarding the wavelets transform (WT), it has been used in the EEG context for the detection of epileptiform patterns [17], for the elimination of different types of noises [18,19] and for removal of some electrophysiological artifacts, such as ocular movement [20,21], and heart signal [20,22].”
MethodArrhythmia ECG Noise Reduction by Ensemble Empirical Mode Decomposition
Chang, K.-M. (2010) · Sensors · doi:10.3390/s100606063 · Cited by 188
Indiradevi, K. P., Elias, E., Sathidevi, P. S., Dinesh Nayak, S., & Radhakrishnan, K. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.04.010 · Cited by 170 · cited 1×
“Regarding the wavelets transform (WT), it has been used in the EEG context for the detection of epileptiform patterns [17], for the elimination of different types of noises [18,19] and for removal of some electrophysiological artifacts, such as ocular movement [20,21], and heart signal [20,22].”
MethodVorobyov, S., & Cichocki, A. (2002) · Biological Cybernetics · doi:10.1007/s00422-001-0298-6 · Cited by 167 · cited 1×
“Independent component analysis (ICA) was successfully applied to EEG denoising for muscular activity [4-13].”
MethodLeVan, P., Urrestarazu, E., & Gotman, J. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.12.013 · Cited by 166 · cited 1×
“Independent component analysis (ICA) was successfully applied to EEG denoising for muscular activity [4-13].”
MethodRemoval of ocular artifacts from EEG using adaptive thresholding of wavelet coefficients
Krishnaveni, V, Jayaraman, S., Anitha, L., & Ramadoss, K. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/011 · Cited by 165 · cited 1×
“Regarding the wavelets transform (WT), it has been used in the EEG context for the detection of epileptiform patterns [17], for the elimination of different types of noises [18,19] and for removal of some electrophysiological artifacts, such as ocular movement [20,21], and heart signal [20,22].”
MethodEmd-Based Signal Noise Reduction
Boudraa, A., Cexus, J.-C., & Saidi, Z. (2007) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.1062809 · Cited by 163
Exploratory fMRI Analysis by Autocorrelation Maximization
Friman, O., Borga, M., Lundberg, P., & Knutsson, H. E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1067 · Cited by 140
Muscle Artifact Removal from Human Sleep EEG by Using Independent Component Analysis
Crespo‐García, M., Atienza, M., & Cantero, J. L. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9442-y · Cited by 138 · cited 1×
“Independent component analysis (ICA) was successfully applied to EEG denoising for muscular activity [4-13].”
MethodCongedo, M., Gouy-Pailler, C., & Jutten, C. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.09.007 · Cited by 136
Grouiller, F., Vercueil, L., Krainik, A., Segebarth, C. M., Kahane, P., & David, O. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.025 · Cited by 132 · cited 1×
“One potential disadvantage is that simulations can lead to biased results in particular when real or simulated muscular activity is added to clean simulated data [13,59].”
BackgroundArtifact reduction in electrogastrogram based on empirical mode decomposition method
Liang, H., Lin, Z., & McCallum, R. W. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344686 · Cited by 132 · cited 1×
“Since then, it has been used in various fields such as biomedical signal analysis [31], Hurst exponent estimation [32], speech processing [33], or texture analysis [34].”
MethodGao, J., Zheng, C., & Wang, P. (2010) · Clinical EEG and Neuroscience · doi:10.1177/155005941004100111 · Cited by 126 · cited 1×
“More recently, another BSS approach called Canonical Correlation Analysis (CCA) was also proposed to remove muscle artifacts from EEG and improve the interpretation of ictal epochs [14-16].”
MethodHalder, S., Bensch, M., Mellinger, J., Bogdan, M., Kübler, A., Birbaumer, N., & Rosenstiel, W. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/82069 · Cited by 123 · cited 1×
“Independent component analysis (ICA) was successfully applied to EEG denoising for muscular activity [4-13].”
MethodInteraction dynamics of neuronal oscillations analysed using wavelet transforms
Li, X., Yao, X., Fox, J., & Jefferys, J. G. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.08.006 · Cited by 119
Electromyogenic artifacts and electroencephalographic inferences revisited
McMenamin, B. W., Shackman, A. J., Greischar, L. L., & Davidson, R. J. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.057 · Cited by 116
Cosandier‐Rimélé, D., Badier, J., Chauvel, P., & Wendling, F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.890489 · Cited by 114 · cited 1×
“To quantitatively evaluate the performance of the four above-mentioned BSS approaches, we simulated 32channels EEG data, with a spatiotemporal model developed by our team [52-54].”
MethodSelf-citationThe neuronal sources of EEG: Modeling of simultaneous scalp and intracerebral recordings in epilepsy
Cosandier‐Rimélé, D., Merlet, I., Badier, J., Chauvel, P., & Wendling, F. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.185 · Cited by 112
Self-citationImproving the Interpretation of Ictal Scalp EEG: BSS–CCA Algorithm for Muscle Artifact Removal
Vergult, A., Clercq, W. D., Palmini, A., Vanrumste, B., Dupont, P. J., Huffel, S. V., & Paesschen, W. V. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01031.x · Cited by 110
Removal of EEG Noise and Artifact Using Blind Source Separation
Fitzgibbon, S. P., Powers, D. M. W., Pope, K. J., & Clark, C. R. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3180556926 · Cited by 106
Empirical Mode Decomposition, fractional Gaussian noise and Hurst exponent estimation
Rilling, G., Flandrin, P., & Gonçalvès, P. (2006) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2005.1416052 · Cited by 89 · cited 2×
“Since then, it has been used in various fields such as biomedical signal analysis [31], Hurst exponent estimation [32], speech processing [33], or texture analysis [34].”
MethodIyer, D., & Zouridakis, G. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.024 · Cited by 84
Wavelet analysis of EEG for three-dimensional mapping of epileptic events
Senhadji, L., Dillenseger, J., Wendling, F., Rocha, C., & Kinie, A. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02584454 · Cited by 74
Self-citationWavelets—a new tool in sleep biosignal analysis
Jobert, M., Tismer, C., Poiseau, É., & Schulz, H. (1994) · Journal of Sleep Research · doi:10.1111/j.1365-2869.1994.tb00135.x · Cited by 68 · cited 1×
“, [36-42]).”
Astronomical Data Analysis and Sparsity: From Wavelets to Compressed Sensing
Starck, J., & Bobin, J. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2025663 · Cited by 67
Localization of extended brain sources from EEG/MEG: The ExSo-MUSIC approach
Birot, G., Albera, L., Wendling, F., & Merlet, I. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.054 · Cited by 64
Self-citationFrequency and Voice: Perspectives in the Time Domain
Roark, R. M. (2006) · Journal of Voice · doi:10.1016/j.jvoice.2005.12.009 · Cited by 57
Wavelet-based EEG denoising for automatic sleep stage classification
Estrada, E. F., Nazeran, H., Sierra, G., Ebrahimi, F., & Setarehdan, S. K. (2011) · International Conference on Electronics, Communications, and Computers · doi:10.1109/conielecomp.2011.5749325 · Cited by 56
Hallez, H., Vos, M. D., Vanrumste, B., Hese, P. V., Assecondi, S., Laere, K. V., Dupont, P. J., Paesschen, W. V., Huffel, S. V., & Lemahieu, I. A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.05.010 · Cited by 48
Computational Modeling of Epileptic Activity: From Cortical Sources to EEG Signals
Cosandier‐Rimélé, D., Merlet, I., Bartoloméi, F., Badier, J., & Wendling, F. (2010) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3182005dcd · Cited by 43
Self-citationIndependent Component Analysis in the Study of Focal Seizures
Iriarte, J., Urrestarazu, E., Artieda, J., Valencia, M., LeVan, P., Viteri, C., & Alegre, M. (2006) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000236579.08698.23 · Cited by 21
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Stalin, S., Roy, V., Shukla, P. K., Zaguia, A., Khan, M. M., Shukla, P. K., & Jain, A. (2021) · Mathematical Problems in Engineering · doi:10.1155/2021/2942808 · Cited by 290
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Imaging natural cognition in action
Gramann, K., Ferris, D. P., Gwin, J., & Makeig, S. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.09.003 · Cited by 227
Metadata
- Authors
- Safieddine, D., Kachenoura, A., Albera, L., Birot, G., Karfoul, A., Pasnicu, A., Biraben, A., Wendling, F., Senhadji, L., & Merlet, I.
- Venue
- EURASIP Journal on Advances in Signal Processing
- Published
- 2012-07-02
- Volume
- 2012
- Issue
- 1
- ISSN
- 1110-8657 (ISSN-L)
- 1687-6180
- OpenAlex
- W2150832917
- Cited by
- 198
- References
- 57
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.