The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Use of weighted Fourier linear combiner filters to estimate lower trunk 3D orientation from gyroscope sensors data
Open accessAbstract
BACKGROUND: The present study aimed at devising a data processing procedure that provides an optimal estimation of the 3-D instantaneous orientation of an inertial measurement unit (IMU). This result is usually obtained by fusing the data measured with accelerometers, gyroscopes, and magnetometers. Nevertheless, issues related to compensation of integration errors and high sensitivity of these devices to magnetic disturbances call for different solutions. In this study, a method based on the use of gyroscope data only is presented, which uses a Weighted Fourier Linear Combiner adaptive filter to perform a drift-free estimate of the 3D orientation of an IMU located on the lower trunk during walking. METHODS: A tuning of the algorithm parameters and a sensitivity analysis to its initial conditions was performed using treadmill walking data from 3 healthy subjects. The accuracy of the method was then assessed using data collected from 15 young healthy subjects during treadmill walking at variable speeds and comparing the pitch, roll, and yaw angles estimated from the gyroscopes data to those obtained with a stereophotogrammetric system. Root mean square (RMS) difference and correlation coefficients (r) were used for this purpose. RESULTS: An optimal set of values of the algorithm parameters was established. At all the observed speeds, and also in all the various sub-phases, the investigated angles were all estimated to within an average RMS difference of less than 1.2 deg and an average r greater than 0.90. CONCLUSIONS: This study proved the effectiveness of the Weighted Fourier Linear Combiner method in accurately reconstructing the 3D orientation of an IMU located on the lower trunk of a subject during treadmill walking. This method is expected to also perform satisfactorily for overground walking data and to be applicable also to other "quasi-periodic" tasks, such as squatting, rowing, running, or swimming.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Real-time tremor compensation in robotics surgical instruments, requires the processes of tremor sensing and compensation to finish within a very short time, maximum 30ms [37].”
From A Quaternion Weighted Fourier Linear Combiner for Modeling Physiological Tremor (2016) · cites this paper as [37]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“This delay is within the range suggested by [37] but could degrade accuracy.”
From A Quaternion Weighted Fourier Linear Combiner for Modeling Physiological Tremor (2016) · cites this paper as [37]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1991) · Springer eBooks · doi:10.1007/978-3-7091-2840-4 · Cited by 5,095
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Self-citationEstimation of gait cycle characteristics by trunk accelerometry
Moe-Nilssen, R., & Helbostad, J. L. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00233-1 · Cited by 640
Human movement analysis using stereophotogrammetry
Chiari, L., Croce, U. D., Leardini, A., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.004 · Cited by 441
Self-citationHuman movement analysis using stereophotogrammetryPart 1: theoretical background
CAPPOZZO, A., DELLACROCE, U., LEARDINI, A., & CHIARI, L. (2005) · Gait & Posture · doi:10.1016/s0966-6362(04)00025-6 · Cited by 398
Self-citationApplications of magnetic sensors for low cost compass systems
Caruso, M. J. (2002) · IEEE 2000. Position Location and Navigation Symposium (Cat. No.00CH37062) · doi:10.1109/plans.2000.838300 · Cited by 262
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260
Balasubramanian, C. K., Neptune, R. R., & Kautz, S. A. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.10.061 · Cited by 250
Adaptive Fourier estimation of time-varying evoked potentials
Vaz, C. A., & Thakor, N. V. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.18751 · Cited by 159
Body position can be monitored in 3D using miniature accelerometers and earth-magnetic field sensors
Kemp, B., Janssen, A. J. M. W., & van der Kamp, B. (1998) · Electroencephalography and Clinical Neurophysiology/Electromyography and Motor Control · doi:10.1016/s0924-980x(98)00053-8 · Cited by 124
Cited by
Bergamini, E., Ligorio, G., Summa, A., Vannozzi, G., Cappozzo, A., & Sabatini, A. (2014) · Sensors · doi:10.3390/s141018625 · Cited by 267
Self-citationInertial Sensor Technology for Elite Swimming Performance Analysis: A Systematic Review
Mooney, R., Corley, G., Godfrey, A., Quinlan, L., & ÓLaighin, G. (2015) · Sensors · doi:10.3390/s16010018 · Cited by 168
Human–Robot–Environment Interaction Interface for Smart Walker Assisted Gait: AGoRA Walker
M., S. D. S., Garzón, M., Múnera, M., & Cifuentes, C. A. (2019) · Sensors · doi:10.3390/s19132897 · Cited by 80
Joint Inertial Sensor Orientation Drift Reduction for Highly Dynamic Movements
Fasel, B., Spörri, J., Chardonnens, J., Kröll, J., Müller, E. A., & Aminian, K. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2659758 · Cited by 80
Bonnet, V., Joukov, V., Kulić, D., Fraisse, P., Ramdani, N., & Venture, G. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2503765 · Cited by 68
Self-citation
Metadata
- Authors
- Bonnet, V., Mazzà, C., McCamley, J., & Cappozzo, A.
- Affiliations
- Foro Italico University of Rome (IT)
- Corresponding author
- Bonnet, Vincent
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2013
- Volume
- 10
- Issue
- 1
- Pages
- 29
- ISSN
- 1743-0003 (ISSN-L)
- PMC
- PMC3620521
- OpenAlex
- W2129010518
- Semantic Scholar
- 17554c40ee551b1fc905ed17f3ab803d4f04f633
- Cited by
- 32
- References
- 19
- Citations by year
- 2023: 1 · 2021: 3 · 2020: 2 · 2019: 4 · 2018: 2 · 2017: 5 · 2016: 3 · 2015: 5 · 2014: 4 · 2013: 3
- FWCI
- 8.05
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Journal of NeuroEngineering and Rehabilitation (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
- Funders
- Ministero dello Sviluppo Economico
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Keywords
- gyroscope, inertial measurement unit, 3D orientation estimation, lower trunk, treadmill walking, adaptive filtering, gait analysis, stereophotogrammetry, quasi-periodic motion
- MeSH terms
- Acceleration, Adult, Algorithms, Biomechanical Phenomena, Data Interpretation, Statistical, Female, Fourier Analysis, Humans, Male, Middle Aged, Thorax, Least-Squares Analysis, Walking, Imaging, Three-Dimensional, Young Adult, Torso
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of weighted Fourier linear combiner filters to estimate lower trunk 3D orientation from gyroscope sensors data. https://app.cochat.ai/papers/10.1186/1743-0003-10-29
- The paper
- Bonnet, V., Mazzà, C., McCamley, J., & Cappozzo, A. (2013). Use of weighted Fourier linear combiner filters to estimate lower trunk 3D orientation from gyroscope sensors data. Journal of NeuroEngineering and Rehabilitation. https://doi.org/10.1186/1743-0003-10-29
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.