Estimation of step-by-step spatio-temporal parameters of normal and impaired gait using shank-mounted magneto-inertial sensors: application to elderly, hemiparetic, parkinsonian and choreic gait
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The step-by-step determination of the spatio-temporal parameters of gait is clinically relevant since it provides an estimation of the variability of specific gait patterns associated with frequent geriatric syndromes. In recent years, several methods, based on the use of magneto-inertial units (MIMUs), have been developed for the step-by-step estimation of the gait temporal parameters. However, most of them were applied to the gait of healthy subjects and/or of a single pathologic population. Moreover, spatial parameters in pathologic populations have been rarely estimated step-by-step using MIMUs. The validity of clinically suitable MIMU-based methods for the estimation of spatio-temporal parameters is therefore still an open issue. The aim of this study was to propose and validate a method for the determination of both temporal and spatial parameters that could be applied to normal and heavily compromised gait patterns. METHODS: Two MIMUs were attached above each subject's ankles. An instrumented gait mat was used as gold standard. Gait data were acquired from ten hemiparetic subjects, ten choreic subjects, ten subjects with Parkinson's disease and ten healthy older adults walking at two different gait speeds. The method detects gait events (GEs) taking advantage of the cyclic nature of gait and exploiting some lower limb invariant kinematic characteristics. A combination of a MIMU axes realignment along the direction of progression and of an optimally filtered direct and reverse integration is used to determine the stride length. RESULTS: Over the 4,514 gait cycles analyzed, neither missed nor extra GEs were generated. The errors in identifying both initial and final contact at comfortable speed ranged between 0 and 11 ms for the different groups analyzed. The stride length was estimated for all subjects with less than 3% error. CONCLUSIONS: The proposed method is apparently extremely robust since gait speed did not substantially affect its performance and both missed and extra GEs were avoided. The spatio-temporal parameters estimates showed smaller errors than those reported in previous studies and a similar level of precision and accuracy for both healthy and pathologic gait patterns. The combination of robustness, precision and accuracy suggests that the proposed method is suitable for routine clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Unified Parkinson's Disease Rating Scale
(2012) · SpringerReference · doi:10.1007/springerreference_184495 · Cited by 3,066
Gait variability and fall risk in community-living older adults: A 1-year prospective study
Hausdorff, J. M., Rios, D. A., & Edelberg, H. K. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.24893 · Cited by 2,313 · cited 1×
“Variability of gait parameters has been associated with frequent geriatric syndromes such as falls, dementia and frailty [6].”
BackgroundSelf-citationUnified Huntington's disease rating scale: Reliability and consistency
(1996) · Movement Disorders · doi:10.1002/mds.870110204 · Cited by 2,079
Clinical Gait Assessment in the Neurologically Impaired
Holden, M. K., Gill, K. M., Magliozzi, M. R., Nathan, J., & Piehl-Baker, L. (1984) · Physical Therapy · doi:10.1093/ptj/64.1.35 · Cited by 1,499
Pedestrian Tracking with Shoe-Mounted Inertial Sensors
Foxlin, E. (2005) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2005.140 · Cited by 1,399 · cited 1×
“The zero velocity update (ZUPT) is generally applied for this purpose to foot mounted MIMUs at the instant of flat foot [26,28,48]; when the MIMU is mounted on the shank, an inverted pendulum model is often used to estimate the initial integration value [30].”
MethodUnified Huntington's disease rating scale: reliability and consistency
Kremer, H. P. H. (1996) · Radboud Repository (Radboud University) · Cited by 1,059
Gait variability: methods, modeling and meaning
Hausdorff, J. M. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-19 · Cited by 934
Self-citationAssessment of spatio-temporal gait parameters from trunk accelerations during human walking
Zijlstra, W., & Hof, A. L. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00190-x · Cited by 870
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 6×
“Some studies applied the proposed method to the gait of elderly [24,28], spinal cord injuried [17], Parkinsonian [15,27,32], amputee [22] or patient’s with prostheses [49].”
BackgroundMethodInfluential
Cited by
Free‐living monitoring of Parkinson's disease: Lessons from the field
Del Din, S., Godfrey, A., Mazzà, C., Lord, S., & Rochester, L. (2016) · Movement Disorders · doi:10.1002/mds.26718 · Cited by 370
Kobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Wearable inertial sensors for human movement analysis
Iosa, M., Picerno, P., Paolucci, S., & Morone, G. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1198694 · Cited by 281
Zanardi, A. P. J., da Silva, E. S., Costa, R. R., Passos-Monteiro, E., dos Santos, I. O., Kruel, L. F. M., & Peyré-Tartaruga, L. A. (2021) · Scientific Reports · doi:10.1038/s41598-020-80768-2 · Cited by 249
Mannini, A., Trojaniello, D., Cereatti, A., & Sabatini, A. (2016) · Sensors · doi:10.3390/s16010134 · Cited by 242
“, gait spatio-temporal parameters, gait variability) and the quality and quantity of physical activity in both healthy and pathological populations [5–7].”
BackgroundSelf-citationPicerno, P. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2016.11.008 · Cited by 237
Pacini Panebianco, G., Bisi, M. C., Stagni, R., & Fantozzi, S. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.08.025 · Cited by 188
Storm, F. A., Buckley, C. J., & Mazzà, C. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.08.012 · Cited by 182
Gait analysis in neurological populations: Progression in the use of wearables
Celik, Y., Stuart, S., Woo, W. L., & Godfrey, A. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.11.005 · Cited by 167
“The FC was identified as the instant of minimum AP acceleration in the TFC, since it is expected to occur at the time of a sudden motion of the shank preceding the instant of the last maximum AP acceleration value in TFC [205].”
MethodPalmerini, L., Reggi, L., Bonci, T., Del Din, S., Micó-Amigo, M. E., Salis, F., Bertuletti, S., Caruso, M., Cereatti, A., Gazit, E., et al. (2023) · Scientific Data · doi:10.1038/s41597-023-01930-9 · Cited by 52
Self-citationRabelo, A. G., Neves, L. P., Paixão, A. P. S., Oliveira, F. H. M., de Souza, L. A. P. S., Vieira, M. F., Pereira, A. A., & Andrade, A. O. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1908-3 · Cited by 46
Metadata
- Authors
- Trojaniello, D., Cereatti, A., Pelosin, E., Avanzino, L., Mirelman, A., Hausdorff, J. M., & Della Croce, U.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2014
- Volume
- 11
- Issue
- 1
- Pages
- 152
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2132279149
- Cited by
- 244
- References
- 57
- FWCI
- 36.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.