Estimation of step-by-step spatio-temporal parameters of normal and impaired gait using shank-mounted magneto-inertial sensors: application to elderly, hemiparetic, parkinsonian and choreic gait
Open accessThe DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The step-by-step determination of the spatio-temporal parameters of gait is clinically relevant since it provides an estimation of the variability of specific gait patterns associated with frequent geriatric syndromes. In recent years, several methods, based on the use of magneto-inertial units (MIMUs), have been developed for the step-by-step estimation of the gait temporal parameters. However, most of them were applied to the gait of healthy subjects and/or of a single pathologic population. Moreover, spatial parameters in pathologic populations have been rarely estimated step-by-step using MIMUs. The validity of clinically suitable MIMU-based methods for the estimation of spatio-temporal parameters is therefore still an open issue. The aim of this study was to propose and validate a method for the determination of both temporal and spatial parameters that could be applied to normal and heavily compromised gait patterns. METHODS: Two MIMUs were attached above each subject's ankles. An instrumented gait mat was used as gold standard. Gait data were acquired from ten hemiparetic subjects, ten choreic subjects, ten subjects with Parkinson's disease and ten healthy older adults walking at two different gait speeds. The method detects gait events (GEs) taking advantage of the cyclic nature of gait and exploiting some lower limb invariant kinematic characteristics. A combination of a MIMU axes realignment along the direction of progression and of an optimally filtered direct and reverse integration is used to determine the stride length. RESULTS: Over the 4,514 gait cycles analyzed, neither missed nor extra GEs were generated. The errors in identifying both initial and final contact at comfortable speed ranged between 0 and 11 ms for the different groups analyzed. The stride length was estimated for all subjects with less than 3% error. CONCLUSIONS: The proposed method is apparently extremely robust since gait speed did not substantially affect its performance and both missed and extra GEs were avoided. The spatio-temporal parameters estimates showed smaller errors than those reported in previous studies and a similar level of precision and accuracy for both healthy and pathologic gait patterns. The combination of robustness, precision and accuracy suggests that the proposed method is suitable for routine clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Unified Parkinson's Disease Rating Scale
(2012) · SpringerReference · doi:10.1007/springerreference_184495 · Cited by 3,066
Gait variability and fall risk in community-living older adults: A 1-year prospective study
Hausdorff, J. M., Rios, D. A., & Edelberg, H. K. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.24893 · Cited by 2,313 · cited 1×
“Variability of gait parameters has been associated with frequent geriatric syndromes such as falls, dementia and frailty [6].”
BackgroundSelf-citationUnified Huntington's disease rating scale: Reliability and consistency
(1996) · Movement Disorders · doi:10.1002/mds.870110204 · Cited by 2,079
Clinical Gait Assessment in the Neurologically Impaired
Holden, M. K., Gill, K. M., Magliozzi, M. R., Nathan, J., & Piehl-Baker, L. (1984) · Physical Therapy · doi:10.1093/ptj/64.1.35 · Cited by 1,499
Pedestrian Tracking with Shoe-Mounted Inertial Sensors
Foxlin, E. (2005) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2005.140 · Cited by 1,399 · cited 1×
“The zero velocity update (ZUPT) is generally applied for this purpose to foot mounted MIMUs at the instant of flat foot [26,28,48]; when the MIMU is mounted on the shank, an inverted pendulum model is often used to estimate the initial integration value [30].”
MethodUnified Huntington's disease rating scale: reliability and consistency
Kremer, H. P. H. (1996) · Radboud Repository (Radboud University) · Cited by 1,059
Gait variability: methods, modeling and meaning
Hausdorff, J. M. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-19 · Cited by 934
Self-citationAssessment of spatio-temporal gait parameters from trunk accelerations during human walking
Zijlstra, W., & Hof, A. L. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00190-x · Cited by 870
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 6×
“Some studies applied the proposed method to the gait of elderly [24,28], spinal cord injuried [17], Parkinsonian [15,27,32], amputee [22] or patient’s with prostheses [49].”
BackgroundMethodInfluentialGait Analysis Using a Shoe-Integrated Wireless Sensor System
Bamberg, S., Benbasat, A. Y., Scarborough, D. M., Krebs, D. E., & Paradiso, J. A. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.899493 · Cited by 737 · cited 1×
“pressure sensors [9]) have also been used to estimate GE timings from body segment motion [10,11].”
MethodChen, G., Patten, C., Kothari, D. H., & Zajac, F. E. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.06.009 · Cited by 701 · cited 2×
“A step-by-step determination of the spatio-temporal parameters is of great clinical relevance [2-5].”
BackgroundGait Assessment in Parkinson's Disease: Toward an Ambulatory System for Long-Term Monitoring
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Dehollain, C., Blanc, Y., Burkhard, P. R., & Aminian, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827933 · Cited by 659 · cited 11×
“Some studies applied the proposed method to the gait of elderly [24,28], spinal cord injuried [17], Parkinsonian [15,27,32], amputee [22] or patient’s with prostheses [49].”
BackgroundMethodResultInfluentialAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650 · cited 9×
“In fact, in both normal [26] and Parkinson’s disease gait [27], the ωz recorded from either the shank or the foot shows the largest values at mid-swing and a TSW can be defined as the time interval with ωz larger than a set threshold (20%) of its local maximum value Mp.”
BackgroundMethodInfluentialHuman movement analysis using stereophotogrammetryPart 1: theoretical background
CAPPOZZO, A., DELLACROCE, U., LEARDINI, A., & CHIARI, L. (2005) · Gait & Posture · doi:10.1016/s0966-6362(04)00025-6 · Cited by 398 · cited 1×
“For each gait cycle analyzed, a specific motor task coordinate system (MTCS) was defined [55]; the vertical axis (V) was made to coincide with the gravity direction whereas the anterior-posterior (AP) axis was made to coincide with the direction of progression, which was determined as the direction of maximum average…”
MethodSelf-citationJasiewicz, J. M., Allum, J. H. J., Middleton, J. W., Barriskill, A., Condie, P., Purcell, B., & Li, R. C. T. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.12.017 · Cited by 371
3D gait assessment in young and elderly subjects using foot-worn inertial sensors
Mariani, B., Hoskovec, C., Rochat, S., Büla, C., Penders, J., & Aminian, K. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.07.003 · Cited by 370 · cited 5×
“Some studies applied the proposed method to the gait of elderly [24,28], spinal cord injuried [17], Parkinsonian [15,27,32], amputee [22] or patient’s with prostheses [49].”
BackgroundMethodInfluentialMethods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350 · cited 1×
“pressure sensors [9]) have also been used to estimate GE timings from body segment motion [10,11].”
MethodWeiss, A., Brozgol, M., Dorfman, M., Herman, T., Shema, S., Giladi, N., & Hausdorff, J. M. (2013) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968313491004 · Cited by 304 · cited 1×
“In addition, gait variability has been associated with fall risk and disease progression in patients with Parkinson’s disease [7,8].”
BackgroundSelf-citationCapturing human motion using body‐fixed sensors: outdoor measurement and clinical applications
Aminian, K., & Najafi, B. (2004) · Computer Animation and Virtual Worlds · doi:10.1002/cav.2 · Cited by 280 · cited 1×
“However, MIMU-based recordings require appropriate processing to estimate gait parameters for clinical applications [12].”
MethodQuantitative estimation of foot-flat and stance phase of gait using foot-worn inertial sensors
Mariani, B., Rouhani, H., Crevoisier, X., & Aminian, K. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2012.07.012 · Cited by 258 · cited 4×
“Most of the studies mentioned above validated the proposed GE detection methods on healthy subjects [13,14,16,19,23,26].”
BackgroundMethodInfluentialBalasubramanian, C. K., Neptune, R. R., & Kautz, S. A. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.10.061 · Cited by 250
McCamley, J., Donati, M., Grimpampi, E., & Mazzà, C. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.02.019 · Cited by 241
Numerical double integration of acceleration measurements in noise
Thong, Y. K., Woolfson, M. S., Crowe, J. A., Hayes-Gill, B. R., & Jones, D. A. (2004) · Measurement · doi:10.1016/j.measurement.2004.04.005 · Cited by 206 · cited 1×
“However, due to the presence of drift in acceleration signals [45], the inaccuracy related to the estimation of the MIMU orientation [46] and the value of the constant of integration of the relevant signals (initial condition) [47], the estimate of gait spatial parameters is extremely poor unless some countermeasures…”
BackgroundReal-time gait event detection for normal subjects from lower trunk accelerations
González, R. C., López, A. M., Rodriguez-Uría, J., Álvarez, D., & Alvarez, J. C. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.11.014 · Cited by 205
Inertial Sensor-Based Methods in Walking Speed Estimation: A Systematic Review
Yang, S., & Li, Q. (2012) · Sensors · doi:10.3390/s120506102 · Cited by 204 · cited 2×
“Since such models are based on the observation of physiological gait, accuracy issues in applying them to pathological gait patterns have been reported [44].”
BackgroundMethodAn adaptive gyroscope-based algorithm for temporal gait analysis
Greene, B. R., McGrath, D., O’Neill, R., O’Donovan, K. J., Burns, A., & Caulfield, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0692-0 · Cited by 199 · cited 5×
“A number of authors have proposed methods applied to MIMU measurements for estimating gait temporal parameters [13-23] or spatio-temporal parameters [24-32].”
BackgroundMethodResultInfluentialGait Event Detection on Level Ground and Incline Walking Using a Rate Gyroscope
Catalfamo, P., Ghoussayni, S., & Ewins, D. (2010) · Sensors · doi:10.3390/s100605683 · Cited by 187 · cited 5×
“A number of authors have proposed methods applied to MIMU measurements for estimating gait temporal parameters [13-23] or spatio-temporal parameters [24-32].”
BackgroundMethodInfluentialReal-time gait event detection using wearable sensors
Hanlon, M., & Anderson, R. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.07.128 · Cited by 187 · cited 3×
“Most of the studies mentioned above validated the proposed GE detection methods on healthy subjects [13,14,16,19,23,26].”
BackgroundMethodMeasurement of foot placement and its variability with inertial sensors
Rebula, J. R., Ojeda, L. V., Adamczyk, P. G., & Kuo, A. D. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.05.012 · Cited by 180 · cited 2×
“compensated linear acceleration in the global reference frame [31,37].”
BackgroundMethodMannini, A., & Sabatini, A. M. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.06.017 · Cited by 179 · cited 4×
“Most of the studies mentioned above validated the proposed GE detection methods on healthy subjects [13,14,16,19,23,26].”
BackgroundMethodInfluentialAutomatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
Willemsen, A. T. M., Bloemhof, F., & Boom, H. B. K. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.64463 · Cited by 169 · cited 2×
“When the MIMU is attached to a lower limb segment, the GEs detection and the determination of gait cycle phases is often based on the analysis of the sagittal angular velocity features [13,14,23,26,27] or, less frequently, of the acceleration features [15,17,19,20], applying approaches such as empirically determined t…”
MethodAutomatic Detection of Temporal Gait Parameters in Poststroke Individuals
Lopez‐Meyer, P., Fulk, G. D., & Sazonov, E. E. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2112773 · Cited by 168 · cited 1×
“Spatial parameters in pathologic gait have been estimated mostly as average values and only in a few studies on a step-by-step basis [24,26-29,32,50].”
BackgroundGait in patients with cerebellar ataxia
Palliyath, S., Hallett, M., Thomas, S. L., & Lebiedowska, M. K. (1998) · Movement Disorders · doi:10.1002/mds.870130616 · Cited by 165 · cited 1×
“Other gait abnormalities, such as choreiform gait, also known as "drunken gait", are characterized by staggering from side to side, with lateral swaying, and stride-by-stride lateral deviations from forward direction during walking [51], while Parkinsonian gait is generally characterized by small shuffling steps and a…”
BackgroundLau, H., & Tong, K. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.03.018 · Cited by 165 · cited 2×
“A larger number of methods have been proposed using MIMUs attached to the lower limbs: on the feet or shoes [19,23,25,26], on the shanks [13-16,27], thighs [21], or both shanks and thighs [18,24].”
MethodAminian, K., Trevisan, C., Najafi, B., Dejnabadi, H., Frigo, C., Pavan, E., Telonio, A., Cerati, F., Marinoni, E. C., Robert, P., et al. (2004) · Gait & Posture · doi:10.1016/s0966-6362(03)00093-6 · Cited by 164 · cited 2×
“For the elderly group, stride length estimation errors were negligible and comparable to those found in [49].”
MethodResultSelles, R. W., Formanoy, M. A. G., Bussmann, J. B. J., Janssens, P. J., & Stam, H. J. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.843176 · Cited by 151 · cited 2×
“Some studies applied the proposed method to the gait of elderly [24,28], spinal cord injuried [17], Parkinsonian [15,27,32], amputee [22] or patient’s with prostheses [49].”
MethodBilateral step length estimation using a single inertial measurement unit attached to the pelvis
Köse, A., Cereatti, A., & Croce, U. D. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-9 · Cited by 150
Self-citationPeruzzi, A., Croce, U. D., & Cereatti, A. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.04.035 · Cited by 145 · cited 3×
“However, due to the presence of drift in acceleration signals [45], the inaccuracy related to the estimation of the MIMU orientation [46] and the value of the constant of integration of the relevant signals (initial condition) [47], the estimate of gait spatial parameters is extremely poor unless some countermeasures…”
BackgroundMethodSelf-citationTrojaniello, D., Cereatti, A., & Croce, U. D. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.07.007 · Cited by 131
Self-citationEstimation of spatio-temporal parameters for post-stroke hemiparetic gait using inertial sensors
Yang, S., Zhang, J., Novak, A. C., Brouwer, B. J., & Li, Q. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.07.032 · Cited by 130 · cited 2×
“The zero velocity update (ZUPT) is generally applied for this purpose to foot mounted MIMUs at the instant of flat foot [26,28,48]; when the MIMU is mounted on the shank, an inverted pendulum model is often used to estimate the initial integration value [30].”
MethodAdaptive step length estimation algorithm using optimal parameters and movement status awareness
Shin, S. H., & Park, C. G. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.04.009 · Cited by 120
Accurate and Reliable Gait Cycle Detection in Parkinson's Disease
Hundza, S. R., Hook, W. R., Harris, C. R., Mahajan, S. V., Leslie, P. A., Spani, C. A., Spalteholz, L. G., Birch, B. J., Commandeur, D. T., & Livingston, N. J. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282080 · Cited by 118 · cited 6×
“Some studies applied the proposed method to the gait of elderly [24,28], spinal cord injuried [17], Parkinsonian [15,27,32], amputee [22] or patient’s with prostheses [49].”
BackgroundMethodResultInfluentialDalton, A. F., Khalil, H. W., Busse, M. E., Rosser, A., Deursen, R. W. M. V., & OLaighin, G. M. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.05.028 · Cited by 113 · cited 1×
“A single sensor placed on the lower trunk has been proposed for healthy subjects [33-37 and pathologic gait [38-42].”
Esser, P., Dawes, H., Collett, J., Feltham, M. G., & Howells, K. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.06.018 · Cited by 106 · cited 1×
“A single sensor placed on the lower trunk has been proposed for healthy subjects [33-37 and pathologic gait [38-42].”
Veltink, P. H., Slycke, P., Hemssems, J., Buschman, R., Bultstra, G., & Hermens, H. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00041-3 · Cited by 99 · cited 3×
“A larger number of methods have been proposed using MIMUs attached to the lower limbs: on the feet or shoes [19,23,25,26], on the shanks [13-16,27], thighs [21], or both shanks and thighs [18,24].”
BackgroundMethodYoneyama, M., Kurihara, Y., Watanabe, K., & Mitoma, H. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2268251 · Cited by 98 · cited 1×
“A single sensor placed on the lower trunk has been proposed for healthy subjects [33-37 and pathologic gait [38-42].”
Yoneyama, M., Kurihara, Y., Watanabe, K., & Mitoma, H. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2260561 · Cited by 95
A spot check for assessing static orientation consistency of inertial and magnetic sensing units
Picerno, P., Cereatti, A., & Cappozzo, A. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2010.12.006 · Cited by 90 · cited 3×
“The latter MTCS has the advantage to do not be affected by errors in the heading estimates [46].”
BackgroundMethodSelf-citationReliability of spatiotemporal gait outcome measures in Huntington's disease
Rao, A. K., Quinn, L., & Marder, K. S. (2005) · Movement Disorders · doi:10.1002/mds.20482 · Cited by 86 · cited 1×
“A step-by-step determination of the spatio-temporal parameters is of great clinical relevance [2-5].”
BackgroundPart 1: Theoretical Background
(1987) · Mouton eBooks · doi:10.1515/9783110250503.5 · Cited by 73
Esser, P., Dawes, H., Collett, J., Feltham, M. G., & Howells, K. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.01.005 · Cited by 67 · cited 1×
“A single sensor placed on the lower trunk has been proposed for healthy subjects [33-37 and pathologic gait [38-42].”
Greene, B. R., Foran, T. G., McGrath, D., Doheny, E. P., Burns, A., & Caulfield, B. (2012) · Journal of Applied Biomechanics · doi:10.1123/jab.28.3.349 · Cited by 58 · cited 4×
“Spatial parameters in pathologic gait have been estimated mostly as average values and only in a few studies on a step-by-step basis [24,26-29,32,50].”
BackgroundMethodResultInfluentialValidity of DynaPort GaitMonitor for assessment of spatiotemporal parameters in amputee gait.
Houdijk, H., Appelman, F. M., van Velzen, J. M., van der Woude, L. H. V., & van Bennekom, C. A. M. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.12.0209 · Cited by 57
Spatiotemporal Parameters of Gait During Treadmill and Overground Walking in Parkinson's Disease
Bello, O., Sánchez, J. A., Santos, C., & Fernández‐del‐Olmo, M. (2014) · Journal of Parkinson s Disease · doi:10.3233/jpd-130251 · Cited by 36 · cited 2×
“A step-by-step determination of the spatio-temporal parameters is of great clinical relevance [2-5].”
BackgroundHan, J., Jeon, H. S., Yi, W. J., Jeon, B. S., & Park, K. S. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0521-5 · Cited by 20 · cited 4×
“When the MIMU is attached to a lower limb segment, the GEs detection and the determination of gait cycle phases is often based on the analysis of the sagittal angular velocity features [13,14,23,26,27] or, less frequently, of the acceleration features [15,17,19,20], applying approaches such as empirically determined t…”
MethodInfluentialTrojaniello, D., Cereatti, A., Ravaschio, A., Bandettini, M. P., & Croce, U. D. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944132 · Cited by 15
Self-citation
Cited by
Free‐living monitoring of Parkinson's disease: Lessons from the field
Del Din, S., Godfrey, A., Mazzà, C., Lord, S., & Rochester, L. (2016) · Movement Disorders · doi:10.1002/mds.26718 · Cited by 370
Kobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Wearable inertial sensors for human movement analysis
Iosa, M., Picerno, P., Paolucci, S., & Morone, G. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1198694 · Cited by 281
Zanardi, A. P. J., da Silva, E. S., Costa, R. R., Passos-Monteiro, E., dos Santos, I. O., Kruel, L. F. M., & Peyré-Tartaruga, L. A. (2021) · Scientific Reports · doi:10.1038/s41598-020-80768-2 · Cited by 249
Mannini, A., Trojaniello, D., Cereatti, A., & Sabatini, A. (2016) · Sensors · doi:10.3390/s16010134 · Cited by 242
“, gait spatio-temporal parameters, gait variability) and the quality and quantity of physical activity in both healthy and pathological populations [5–7].”
BackgroundSelf-citation
Metadata
- Authors
- Trojaniello, D., Cereatti, A., Pelosin, E., Avanzino, L., Mirelman, A., Hausdorff, J. M., & Della Croce, U.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2014
- Volume
- 11
- Issue
- 1
- Pages
- 152
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2132279149
- Cited by
- 244
- References
- 57
- FWCI
- 36.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.